Average cooling efficiency and below average heating efficiency for a 4-ton central heat pump, but not rated for cold climates.

Ranks #162 of 319 4 ton central heat pumps for cooling efficiency, and costs about $1,652 a year to run in a mixed climate like Atlanta.

SEER2
17.1 Cooling efficiency over a season
Average · beats 53%
HSPF2
8.5 Heating efficiency over a season
Below average · beats 38%
EER2
12.0 Cooling efficiency on a 95°F day
Average · beats 64%
Heat at 5°F
40,000 BTU/h73% of its 47°F output
Below average · beats 5%

A good fit if…

  • You want steady temperatures and quiet running - the compressor varies its speed.
  • You want a choice of indoor units - 58 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.
  • You want the newest refrigerant - it uses R-410A, which is being phased down.

Calculate my running cost

Details

Specifications4 ton, R-410A
General
BrandTrane
Also sold asAmerican Standard
Outdoor unit model4TWV7X60A1
SeriesXV17
TypeCentral heat pump
Nominal size4 ton
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-410A
Connected (smart) capableNo
On the market sinceApril 25, 2024
Last certifiedFebruary 17, 2025
Cooling
SEER2Seasonal efficiency, higher is better17.1 (range 17.0-17.1)
EER2Efficiency at 95°F outdoors11.7-12.0
Cooling capacity52,500-54,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better8.0-8.5
Capacity at 47°F51,500-53,500 BTU/h
Capacity at 17°F48,000-51,000 BTU/h
Capacity at 5°F38,000-40,000 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.60-1.80
ENERGY STAR cold climateNo
Heating output as it gets colder73% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with TEM8A0C48V41+TDR+LRP at the standard test temperatures, in BTU/h:

Certified matchups58 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
TEM8A0C48V41+TDR+LRP-17.112.08.538,000214671749
TEM8B0C60V51+TDR+LRP-17.112.08.538,000214671756
TAMXB0C60V51-17.112.08.239,500212391377
4PX*DU60BS3S8V2D120M5PCA17.111.78.239,500212391558
4PX*DU60BS3S8V2D120M5PDA17.111.78.239,500212391559
4TXCD010DS3S8V2D120M5PCA17.111.78.239,500212391562
4TXCD010DS3S8V2D120M5PDA17.111.78.239,500212391563
4TXCC009DS3S9V2C080U5PSB+LRP17.111.78.239,500213826775
4PX*DU60BS3S9V2D120U5PSC+LRP17.112.08.238,500213826757
4PX*DU60BS3S9V2D120U5PSB+LRP17.112.08.238,500213826759
4TXCC009DS3L8V1C100U5VSB+LRP17.111.78.239,500213826767
4TXCC009DS3S9V2C100U5PSC+LRP17.111.78.239,500213826769
4TXCC009DS3S9V2C080U5PSC+LRP17.111.78.239,500213826773
4TXCC009DS3S9V2C100U5PSB+LRP17.111.78.239,500213826771
4TXCD010DS3*UHMD120CCV5+LRP17.111.78.238,500213826785
4TXCD010DS3*UHMD120ACV5+LRP17.111.78.238,500213826787
4PX*CU60BS3L8V1C100U5VSB+LRP17.111.78.239,500213826745
4TXCD010DS3L8V1C100U5VSB+LRP17.112.08.238,000213826797
4PX*CU60BS3S9V2C080U5PSC+LRP17.111.78.239,500213826747
4TXCD010DS3S9V2D120U5VSB+LRP17.112.08.238,500213826799
4PX*CU60BS3S9V2C100U5PSB+LRP17.111.78.239,500213826739
4PX*CU60BS3S9V2C100U5PSC+LRP17.111.78.239,500213826741
4PX*CU60BS3S9V2C080U5PSB+LRP17.111.78.239,500213826743
4PX*DU60BS3L8V1C100U5VSB+LRP17.112.08.238,000213826751
4PX*DU60BS3S9V2D120U5VSA+LRP17.112.08.238,500213826755
4PX*DU60BS3S9V2D120U5VSB+LRP17.112.08.238,500213826753
4TXCD010DS3S9V2D120U5VSA+LRP17.112.08.238,500213826801
4TXCD010DS3S9V2D120U5PSC+LRP17.112.08.238,500213826803
4TXCD010DS3S9V2D120U5PSB+LRP17.112.08.238,500213826805
4PX*DU60BS3S9V2C100U5PSC+LRP17.111.78.138,000213826761
4PX*DU60BS3S9V2C100U5PSB+LRP17.111.78.138,000213826763
4PX*DU60BS3S9V2C080U5PSC+LRP17.111.78.138,000213826765
4TXCD008DS3S9V2D120U5PSC+LRP17.111.78.139,000213826777
4TXCD008DS3S9V2D120U5PSB+LRP17.111.78.139,000213826779
4TXCD008DS3S9V2D120U5VSA+LRP17.111.78.139,000213826781
4TXCD008DS3S9V2D120U5VSB+LRP17.111.78.139,000213826783
4TXCD010DS3S9V2C100U5PSB+LRP17.111.78.138,000213826789
4TXCD010DS3S9V2C080U5PSB+LRP17.111.78.138,000213826793
4TXCD010DS3S9V2C080U5PSC+LRP17.111.78.138,000213826791
4TXCD010DS3S9V2C100U5PSC+LRP17.111.78.138,000213826795
4PX*DU60BS3S9V2C080U5PSB+LRP17.111.78.138,000213826749
4PX*CD60BS3S9V2C100D5PSC+LRP17.111.78.040,000213826735
4PX*CD60BS3S9V2C100D5PSB+LRP17.111.78.040,000213826737
4PX*DU60BS3S8V2D120M5PCB17.011.78.239,000214639901
4PX*DU60BS3S8V2D120M5PDB17.011.78.239,000214639903
4TXCD010DS3S8V2D120M5PCB17.011.78.239,000214639917
4TXCD010DS3S8V2D120M5PDB17.011.78.239,000214639919
4PX*DU60BS3S8V2C100M5PCB17.011.78.138,000214639899
4TXCD010DS3S8V2C100M5PCB17.011.78.138,000214639913
4TXCD010DS3S8V2C100M5PDB17.011.78.138,000214639915
4PX*CU60BS3S9V2C080U5VSB+LRP17.011.78.139,500215825833
4PX*CU60BS3S9V2C100U5VSB+LRP17.011.78.139,500215825835
4PX*DU60BS3S9V2C100U5VSB+LRP17.011.78.139,500215825841
4PX*DU60BS3S9V2C080U5VSB+LRP17.011.78.139,500215825843
4TXCC009DS3S9V2C080U5VSB+LRP17.011.78.139,500215825845
4TXCC009DS3S9V2C100U5VSB+LRP17.011.78.139,500215825847
4TXCD010DS3S9V2C100U5VSB+LRP17.011.78.139,500215825849
4TXCD010DS3S9V2C080U5VSB+LRP17.011.78.139,500215825851
Same unit, other model numbers1

These model numbers have exactly the same certified ratings and matchups as the Trane 4TWV7X60A1: the same equipment under another brand, or a variant code for voltage, colour or market. Everything on this page applies to them.

Yearly running cost in 10 large cities$1,484-$3,944

At each state's average electricity price and the city's typical heating and cooling hours.

Questions6
What is the SEER2 rating of the Trane 4TWV7X60A1?
The Trane 4TWV7X60A1 is rated at up to 17.1 SEER2 and 12.0 EER2 for cooling and up to 8.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 58 certified matchups SEER2 ranges from 17.0-17.1.
Is the Trane 4TWV7X60A1 good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 4-ton model.
How much does the Trane 4TWV7X60A1 cost to run per year?
At its rated efficiency it costs about $1,484-$3,944 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,826 in Phoenix and $3,293 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Is the Trane 4TWV7X60A1 the same as the American Standard 4A6V7X60A1?
Yes, as far as the certified ratings go. ENERGY STAR lists both model numbers with identical efficiency, capacity and matchups, which means the same outdoor unit sold under a different brand or with a minor variant code (voltage, colour or region). The full list is on this page.
Which indoor units work with the Trane 4TWV7X60A1?
ENERGY STAR lists 58 certified combinations for this outdoor unit. The highest-rated ones use TEM8A0C48V41+TDR+LRP, TEM8B0C60V51+TDR+LRP, TAMXB0C60V51.
What refrigerant does the Trane 4TWV7X60A1 use?
It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,810/yrYou save $958/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Trane 4TWV7X60A1
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,810
Current system, per year
$2,768
You save per year
$958
Payback
21.4 years
Net after 10 years
-$10,919

Cooling $1,112Heating $698Electricity used: 11,312 kWhSaved vs. a minimum-efficiency heat pump: $311

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 4 ton models

See all 319 4 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of February 17, 2025. How we use the data.