4-ton central heat pump · T2 Series
VillaTherm VHP-UCHA-60HDCT-A
Average cooling efficiency and very good heating efficiency for a 4-ton central heat pump, and certified for cold climates.
Ranks #164 of 319 4 ton central heat pumps for cooling efficiency, and costs about $1,536 a year to run in a mixed climate like Atlanta.
- SEER2
- 17.0 Cooling efficiency over a seasonAverage · beats 49%
- HSPF2
- 9.8 Heating efficiency over a seasonVery good · beats 79%
- EER2
- 9.5 Cooling efficiency on a 95°F dayBelow average · beats 5%
- Heat at 5°F
- 40,000 BTU/h71% of its 47°F outputVery good · beats 76%
A good fit if…
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 40,000 BTU/h at 5°F.
- It will heat most of the year - its HSPF2 beats 79% of central heat pumps.
- You want steady temperatures and quiet running - the compressor varies its speed.
Think twice if…
- Nothing stands out - its ratings have no weak spot for its class.
Details
Specifications
| General | |
|---|---|
| Brand | VillaTherm |
| Outdoor unit model | VHP-UCHA-60HDCT-A |
| Series | T2 Series |
| Type | Central heat pump |
| Nominal size | 4 ton |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-454B |
| Connected (smart) capable | No |
| On the market since | January 10, 2026 |
| Last certified | September 16, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 17.0 (range 16.2-17.0) |
| EER2Efficiency at 95°F outdoors | 9.5-10.0 |
| Cooling capacity | 54,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 9.0-9.8 |
| Capacity at 47°F | 54,000 BTU/h |
| Capacity at 17°F | 35,000-50,000 BTU/h |
| Capacity at 5°F | 38,500-40,000 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 2.20 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with VAH-UCHA-60HDC-A at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|
| VAH-UCHA-60HDC-A · cold climate | 17.0 | 9.5 | 9.0 | 38,500 | 218046443 |
| VAH-UCHA-60HDC · cold climate | 17.0 | 9.5 | 9.0 | 38,500 | 218393474 |
| VAH-UCHA-60SHDCALN2 · cold climate | 17.0 | 9.5 | 9.0 | 38,500 | 218775070 |
| VAH-UCHA-60HDC · cold climate | 17.0 | 9.5 | 9.0 | 38,500 | 218775077 |
| VAH-UCHA-60SHDCALN2 · cold climate | 16.2 | 10.0 | 9.8 | 40,000 | 218696919 |
Yearly running cost in 10 large cities
- Phoenix, AZ$1,778/yr
- Miami, FL$1,486/yr
- Houston, TX$1,591/yr
- Atlanta, GA$1,536/yr
- Los Angeles, CA$1,478/yr
- New York, NY$3,579/yr
- Chicago, IL$2,888/yr
- Denver, CO$2,387/yr
- Seattle, WA$1,455/yr
- Minneapolis, MN$2,948/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the VillaTherm VHP-UCHA-60HDCT-A?
- The VillaTherm VHP-UCHA-60HDCT-A is rated at up to 17.0 SEER2 and 9.5 EER2 for cooling and up to 9.8 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 5 certified matchups SEER2 ranges from 16.2-17.0.
- Is the VillaTherm VHP-UCHA-60HDCT-A good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 40,000 BTU/h at 5°F with a COP of 2.20, so it is still 2.2 times as efficient as electric resistance heat at that temperature.
- How much does the VillaTherm VHP-UCHA-60HDCT-A cost to run per year?
- At its rated efficiency it costs about $1,455-$3,579 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,778 in Phoenix and $2,948 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the VillaTherm VHP-UCHA-60HDCT-A?
- ENERGY STAR lists 5 certified combinations for this outdoor unit. The highest-rated ones use VAH-UCHA-60HDC-A, VAH-UCHA-60HDC, VAH-UCHA-60SHDCALN2.
- What refrigerant does the VillaTherm VHP-UCHA-60HDCT-A use?
- It uses R-454B.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 4 ton models
- MDV MOE30U-48HFN1-M-[X] · cold climate17.0 SEER2 · 12.0 HSPF2
- AUX AHU48HPV1BO · cold climate17.0 SEER2 · 9.5 HSPF2
- Trane 4TWV7X60A117.1 SEER2 · 8.5 HSPF2
- TCL H60SDH20XQC · cold climate17.0 SEER2 · 9.5 HSPF2
- Trane 4TWV7X48A117.1 SEER2 · 8.5 HSPF2
- TCL THH55HDI2NAJ0H26 · cold climate17.0 SEER2 · 9.5 HSPF2
- Ducane 4HP18V60P17.1 SEER2 · 8.5 HSPF2
- Jetson HP-48ODU-001 · cold climate17.0 SEER2 · 9.4 HSPF2
See all 319 4 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of September 16, 2026. How we use the data.