HVAC Rated

4-ton central heat pump · XV18I

Trane 4TWV8X60A1

Average cooling efficiency and below average heating efficiency for a 4-ton central heat pump, and certified for cold climates.

Ranks #111 of 319 4 ton central heat pumps for cooling efficiency, and costs about $1,592 a year to run in a mixed climate like Atlanta.

SEER2
18.0 Cooling efficiency over a season
Average · beats 66%
HSPF2
8.5 Heating efficiency over a season
Below average · beats 38%
EER2
12.0 Cooling efficiency on a 95°F day
Average · beats 64%
Heat at 5°F
40,000 BTU/h73% of its 47°F output
Below average · beats 9%

A good fit if…

  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 40,000 BTU/h at 5°F.
  • You want steady temperatures and quiet running - the compressor varies its speed.
  • You want a choice of indoor units - 85 certified pairings.

Think twice if…

  • You mainly need heat - its HSPF2 is below average for central heat pumps.
  • You want the newest refrigerant - it uses R-410A, which is being phased down.

Calculate my running cost

Details

Specifications4 ton, R-410A
General
BrandTrane
Outdoor unit model4TWV8X60A1
SeriesXV18I
TypeCentral heat pump
Nominal size4 ton
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-410A
Connected (smart) capableNo
On the market sinceJanuary 1, 2023
Last certifiedSeptember 24, 2025
Cooling
SEER2Seasonal efficiency, higher is better18.0 (range 18.0)
EER2Efficiency at 95°F outdoors11.7-12.0
Cooling capacity52,500-54,500 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8-8.5
Capacity at 47°F50,000-53,500 BTU/h
Capacity at 17°F48,000-51,000 BTU/h
Capacity at 5°F37,000-40,000 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.60-1.84
ENERGY STAR cold climateYes
Heating output as it gets colder73% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with TEM8B0C60V51+TDR at the standard test temperatures, in BTU/h:

Certified matchups85 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 85 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
TEM8B0C60V51+TDR-18.012.08.537,000207820957
TEM8A0C48V41+TDR-18.012.08.537,000210636927
TEM6A0C48H41+TDR+RP-18.011.78.538,500215429067
4TXCD010DS3+P0V0D000M50SC+RP-18.012.08.239,000207805637
4PX*DU60BS3+P0V0D000M50SC+RP-18.012.08.239,000207805632
TAMXB0C60V51-18.012.08.239,500210929573
4PX*CU60BS3 · cold climateS8V2C100M5PCA18.011.78.240,000210691921
4TXCD010DS3S8V2D120M5PCA18.011.78.239,500210691927
4PX*DU60BS3S8V2D120M5PCA18.011.78.239,500210691923
4TXCC009DS3 · cold climateS8V2C100M5PCA18.011.78.240,000210691925
4TXCD010DS3S9V2D120U5VSA+RP18.012.08.239,500207526499
4PX*DU60BS3S9V2D120U5VSA+RP18.012.08.239,500207526497
4PX*CU60BS3 · cold climateS8V2C100M5PDA18.011.78.240,000211081282
4PX*DU60BS3S8V2D120M5PDA18.011.78.239,500211081285
4TXCC009DS3 · cold climateS8V2C100M5PDA18.011.78.240,000211081286
4TXCD010DS3S8V2D120M5PDA18.011.78.239,500211081288
4PX*DD60BS3+P0V0D000M50SC+RP-18.012.08.239,500207805630
4TXCC009DS3+P0V0C000M50SC+RP-18.012.08.239,000207805635
4PX*CU60BS3+P0V0C000M50SC+RP-18.012.08.239,000207805629
4TXCD008DS3+P0V0D000M50SC+RP-18.012.08.239,500207805636
4PX*CU60BS3L8V1C100U5VSA+RP18.011.78.239,500207526905
4TXCC009DS3L8V1C100U5VSA+RP18.011.78.239,500207526906
4TXCC009DS3S9V2C080U5PSB+RP18.011.78.239,500208185417
4TXCC009DS3S9V2C100U5PSB+RP18.011.78.239,500208185418
4TXCD010DS3S9V2D120U5PSB+RP18.012.08.239,500208185419
4PX*DU60BS3S9V2D120U5PSB+RP18.012.08.239,500208443275
4PX*CU60BS3S9V2C080U5PSB+RP18.011.78.239,500210653707
4PX*CU60BS3S9V2C100U5PSB+RP18.011.78.239,500210653708
4TXCD010DS3*UHMD120CCV518.011.78.239,000213825966
4PX*DU60BS3+P0V0D000M50SD+RP-18.012.08.239,000212621481
4TXCD010DS3+P0V0D000M50SD+RP-18.012.08.239,000212621483
4PX*CU60BS3S9V2C100U5PSC+RP18.011.78.239,500214640087
4PX*CU60BS3S9V2C080U5PSC+RP18.011.78.239,500214640089
4PX*DU60BS3S9V2D120U5PSC+RP18.012.08.238,500214640105
4TXCC009DS3S9V2C100U5PSC+RP18.011.78.239,500214640107
4PX*DU60BS3S9V2D120U5VSB+RP18.012.08.239,500214638963
4TXCC009DS3S9V2C080U5PSC+RP18.011.78.239,500214640109
4TXCD010DS3S9V2D120U5VSB+RP18.012.08.239,500214638967
4TXCD010DS3S9V2D120U5PSC+RP18.012.08.238,500214640113
4PX*DU60BS3 · cold climateS8V2D120M5PCB18.011.78.239,500214253515
4PX*DU60BS3 · cold climateS8V2D120M5PDB18.011.78.239,500214253513
4TXCD010DS3 · cold climateS8V2D120M5PCB18.011.78.239,500214253527
4TXCD010DS3 · cold climateS8V2D120M5PDB18.011.78.239,500214253525
4PX*CU60BS3S9V2C100U5VSB+RP18.011.88.239,500215825921
4PX*CU60BS3S9V2C080U5VSB+RP18.011.78.239,500215825923
4PX*DU60BS3S9V2C100U5VSB+RP18.011.98.239,500215825929
4PX*DU60BS3S9V2C080U5VSB+RP18.011.88.239,500215825931
4TXCC009DS3S9V2C100U5VSB+RP18.011.88.239,500215825933
4TXCC009DS3S9V2C080U5VSB+RP18.011.78.239,500215825935
4TXCD010DS3S9V2C080U5VSB+RP18.011.88.239,500215825937
4TXCD010DS3S9V2C100U5VSB+RP18.011.98.239,500215826451
4PX*CU60BS3L8V1C100U5VSB+RP18.011.78.239,500212630043
4PX*CU60BS3+P0V0C000M50SD+RP-18.012.08.239,000212630045
4PX*DD60BS3+P0V0D000M50SD+RP-18.012.08.239,500212630047
4TXCC009DS3+P0V0C000M50SD+RP-18.012.08.239,000212630055
4TXCC009DS3L8V1C100U5VSB+RP18.011.78.239,500212630057
4TXCD008DS3+P0V0D000M50SD+RP-18.012.08.239,500212630059
4PX*DU60BS3+P0V0C000M50SC+RP-18.012.08.138,000207805633
4TXCD010DS3+P0V0C000M50SC+RP-18.012.08.138,000207805638
4PX*DU60BS3L8V1C100U5VSA+RP18.012.08.138,000210653711
Yearly running cost in 10 large cities$1,410-$3,816

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Trane 4TWV8X60A1?
The Trane 4TWV8X60A1 is rated at up to 18.0 SEER2 and 12.0 EER2 for cooling and up to 8.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with.
Is the Trane 4TWV8X60A1 good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 40,000 BTU/h at 5°F with a COP of 1.84, so it is still 1.8 times as efficient as electric resistance heat at that temperature.
How much does the Trane 4TWV8X60A1 cost to run per year?
At its rated efficiency it costs about $1,410-$3,816 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,745 in Phoenix and $3,193 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Trane 4TWV8X60A1?
ENERGY STAR lists 85 certified combinations for this outdoor unit. The highest-rated ones use TEM8B0C60V51+TDR, TEM8A0C48V41+TDR, TEM6A0C48H41+TDR+RP.
What refrigerant does the Trane 4TWV8X60A1 use?
It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,735/yrYou save $1,009/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Trane 4TWV8X60A1
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,735
Current system, per year
$2,743
You save per year
$1,009
Payback
20.3 years
Net after 10 years
-$10,411

Cooling $1,056Heating $679Electricity used: 10,841 kWhSaved vs. a minimum-efficiency heat pump: $364

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 4 ton models

See all 319 4 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of September 24, 2025. How we use the data.