Average cooling efficiency and below average heating efficiency for a 4-ton central heat pump, but not rated for cold climates.

Ranks #110 of 319 4 ton central heat pumps for cooling efficiency, and costs about $1,339 a year to run in a mixed climate like Atlanta.

SEER2
18.0 Cooling efficiency over a season
Average · beats 66%
HSPF2
8.5 Heating efficiency over a season
Below average · beats 38%
EER2
12.0 Cooling efficiency on a 95°F day
Average · beats 64%
Heat at 5°F
29,400 BTU/h67% of its 47°F output
Below average · beats 39%

A good fit if…

  • You want steady temperatures and quiet running - the compressor varies its speed.
  • You want a choice of indoor units - 207 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.
  • You want the newest refrigerant - it uses R-410A, which is being phased down.

Calculate my running cost

Details

Specifications4 ton, R-410A
General
BrandTrane
Outdoor unit model4TWV8X48A1
SeriesXV18I
TypeCentral heat pump
Nominal size4 ton
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-410A
Connected (smart) capableNo
On the market sinceJanuary 1, 2023
Last certifiedJuly 9, 2025
Cooling
SEER2Seasonal efficiency, higher is better18.0 (range 18.0)
EER2Efficiency at 95°F outdoors11.0-12.0
Cooling capacity44,000-47,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better8.0-8.5
Capacity at 47°F41,000-46,000 BTU/h
Capacity at 17°F35,200-37,800 BTU/h
Capacity at 5°F27,400-29,400 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.68-2.00
ENERGY STAR cold climateNo
Heating output as it gets colder67% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with TEM8B0C60V51+TDR at the standard test temperatures, in BTU/h:

Certified matchups207 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 207 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
TEM8B0C60V51+TDR-18.012.08.528,600207820955
4PX*DU60BS3+P0V0C000M50SC+RP-18.012.08.527,600207805619
4PX*CU60BS3+P0V0C000M50SC+RP-18.012.08.528,600207805607
4TXCD010DS3+P0V0C000M50SC+RP-18.012.08.527,600207805625
4PX*DU60BS3S8V2C080M5PDA18.011.78.527,400211088972
4TXCD010DS3S8V2C080M5PDA18.011.78.527,400211088977
4TXCC009DS3+P0V0C000M50SC+RP-18.012.08.528,600207805622
4PX*DU60BS3+P0V0D000M50SC+RP-18.012.08.528,400207805618
4TXCD010DS3+P0V0D000M50SC+RP-18.012.08.528,400207805626
4PX*CD60BS3+P0V0C000M50SC+RP-18.012.08.528,400207805603
4TXCD008DS3+P0V0D000M50SC+RP-18.012.08.528,800207805623
4TXCD010DS3S9V2C100U5PSB+RP18.011.78.528,000207599993
4TXCC009DS3S8V2C080M5PDA18.011.78.528,400211081277
4TXCC009DS3S8V2C100M5PDA18.011.78.528,600211081278
4TXCD010DS3S8V2C100M5PDA18.011.78.527,600211081280
4PX*DU60BS3S8V2C100M5PDA18.011.78.527,600211081272
4TXCD010DS3S8V2D120M5PDA18.012.08.528,400211081281
4PX*CU60BS3S8V2C080M5PDA18.011.78.528,400211081266
4PX*DU48BS3S8V2D120M5PDA18.011.78.528,800211081270
4PX*CU60BS3S8V2C100M5PDA18.011.78.528,600211081267
4PX*DU60BS3S9V2C100U5PSB+RP18.011.78.528,000207599984
4PX*CD60BS3S8V2C100M5PDA18.011.78.528,600211081261
4TXCD008DS3S8V2D120M5PDA18.011.78.528,800211081279
4PX*DU60BS3S8V2D120M5PDA18.012.08.528,400211081271
4PX*CD60BS3S8V2C080M5PDA18.011.78.528,400211081260
4TXCD010DS3L8V1C100U5VSA+RP18.012.08.527,400207526904
4PX*DU60BS3L8V1C100U5VSA+RP18.012.08.527,400207526902
4TXCD010DS3S9V2D120U5VSA+RP18.012.08.528,600207526494
4TXCD010DS3S8V2C080M5PCA18.011.78.527,400210692197
4PX*DU60BS3S9V2D120U5VSA+RP18.012.08.528,600207526487
4PX*DU60BS3S8V2C080M5PCA18.011.78.527,400210692192
4TXCC009DS3*UD2C080ACV418.011.78.528,600207526295
4PX*DU60BS3*UD2D120ACV518.011.78.528,400207526273
4PX*CU60BS3*UD2C080ACV418.011.78.528,600207526270
TEM8A0C48V41+TDR-18.012.08.528,600207526358
4TXCD010DS3*UD2D120ACV518.011.78.528,400207526300
4TXCD010DS3S8V2C100M5PCA18.011.78.527,600210691919
4TXCD010DS3S8V2D120M5PCA18.012.08.528,400210691920
4PX*DU48BS3S8V2D120M5PCA18.011.78.528,800210691909
4TXCC009DS3S8V2C080M5PCA18.011.78.528,400210691916
4PX*DU60BS3S8V2D120M5PCA18.012.08.528,400210691911
4PX*CD60BS3S8V2C080M5PCA18.011.78.528,400210691899
4PX*CU60BS3S8V2C080M5PCA18.011.78.528,400210691905
4TXCC009DS3S8V2C100M5PCA18.011.78.528,600210691917
4PX*CD60BS3S8V2C100M5PCA18.011.78.528,600210691900
4PX*CU60BS3S8V2C100M5PCA18.011.78.528,600210691906
4PX*DU60BS3S8V2C100M5PCA18.011.78.527,600210691910
4TXCD008DS3S8V2D120M5PCA18.011.78.528,800210691918
4TXCB006DS3+P0V0B000M40SC+RP-18.011.78.528,200211289108
4PX*BU48BS3+P0V0B000M40SC+RP-18.011.78.528,200211289107
4TXCD010DS3S9V2C080U5PSB+RP18.011.78.528,000208185414
4PX*DU60BS3S9V2C100U4VSA+RP18.011.78.527,800207526488
4TXCD010DS3S9V2C100U4VSA+RP18.011.78.527,800207526495
4PX*CU42BS3L8V1C100U5VSA+RP18.011.78.528,800210653669
4PX*DU60BS3S9V2C080U5PSB+RP18.011.78.528,000210653686
4PX*CU60BS3S9V2C100U5PSB+RP18.011.78.528,800208121978
4TXCC009DS3S9V2C080U5PSB+RP18.011.78.529,000208185412
4TXCC009DS3S9V2C100U5PSB+RP18.011.78.528,800208185413
4TXCD010DS3S9V2D120U5PSB+RP18.012.08.528,600208185415
4PX*CD60BS3S9V2C100D4VSA+RP18.011.78.528,800207526480
Yearly running cost in 10 large cities$1,201-$3,198

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Trane 4TWV8X48A1?
The Trane 4TWV8X48A1 is rated at up to 18.0 SEER2 and 12.0 EER2 for cooling and up to 8.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with.
Is the Trane 4TWV8X48A1 good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 4-ton model.
How much does the Trane 4TWV8X48A1 cost to run per year?
At its rated efficiency it costs about $1,201-$3,198 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,478 in Phoenix and $2,671 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Trane 4TWV8X48A1?
ENERGY STAR lists 207 certified combinations for this outdoor unit. The highest-rated ones use TEM8B0C60V51+TDR, 4PX*DU60BS3+P0V0C000M50SC+RP, 4PX*CU60BS3+P0V0C000M50SC+RP.
What refrigerant does the Trane 4TWV8X48A1 use?
It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,466/yrYou save $857/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Trane 4TWV8X48A1
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,466
Current system, per year
$2,323
You save per year
$857
Payback
20.4 years
Net after 10 years
-$8,934

Cooling $900Heating $567Electricity used: 9,163 kWhSaved vs. a minimum-efficiency heat pump: $308

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 4 ton models

See all 319 4 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of July 9, 2025. How we use the data.