Average cooling efficiency and below average heating efficiency for a 4-ton central heat pump, but not rated for cold climates.

Ranks #107 of 319 4 ton central heat pumps for cooling efficiency, and costs about $1,498 a year to run in a mixed climate like Atlanta.

SEER2
18.0 Cooling efficiency over a season
Average · beats 66%
HSPF2
8.5 Heating efficiency over a season
Below average · beats 38%
EER2
13.5 Cooling efficiency on a 95°F day
Excellent · beats 95%
Heat at 5°F
26,600 BTU/h51% of its 47°F output
Excellent · beats 92%

A good fit if…

  • You want a choice of indoor units - 413 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.

Calculate my running cost

Details

Specifications4 ton, R-454B
General
BrandKenmore
Outdoor unit model(C,H,T)5H8T48*K*AAA
SeriesMainline 18 SEER2 HP
TypeCentral heat pump
Nominal size4 ton
CompressorVariable-speed units run longer at low powerTwo-stage
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceNovember 1, 2024
Last certifiedJune 29, 2026
Cooling
SEER2Seasonal efficiency, higher is better18.0 (range 15.2-18.0)
EER2Efficiency at 95°F outdoors11.7-13.5
Cooling capacity45,500-50,500 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8-8.5
Capacity at 47°F48,500-52,500 BTU/h
Capacity at 17°F29,400-32,400 BTU/h
Capacity at 5°F23,200-26,600 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.10-2.34
ENERGY STAR cold climateNo
Heating output as it gets colder51% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with FTMA5B60L0D at the standard test temperatures, in BTU/h:

Certified matchups413 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 413 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
FTMA5B60L0D-18.013.58.124,600216152752
EVD5X61M21A*+WALLCON*80CSU0802120B*18.013.08.023,400216351213
EVD5X61M24A*+WALLCON*97CMN1002122B*18.013.08.023,600216351349
EVD5X61M24A*+WALLCON*80CTL0902120B*18.013.08.023,400216351301
EVD5X61M24A*+WALLCON*80CTL1352422B*18.013.08.023,400216351309
EVD5X61M24A*+WALLCON*80CSU1002120B*18.013.08.023,600216351477
EVD5X61M24A*+WALLCON*96CTN1002122B*18.013.08.023,600216351421
EVD5X61M24A*+WALLCON*96CTN1202422B*18.013.08.023,600216351429
EVD5X61M24A*+WALLCON*80CSU0802120B*18.013.08.023,400216351469
EVD5X61M24A*+WALLCON*97CTN1002122A*18.013.08.023,600216351493
EVD5X61M24A*+WALLCON*97CTN1202422A*18.013.08.023,600216351501
EVD5X61M21A*+WALLCON*80CTL0902120B*18.013.08.023,600216351060
EVD5X61M21A*+WALLCON*80CSU1002120A*18.012.08.025,200216351004
EVD5X61M21A*+WALLCON*80CTL1102120B*18.013.08.023,600216351068
EVD5X61M21A*97VTN1002122A*17.512.58.524,600216351261
EVD5X61M24A*95MSU1002122A*17.512.58.525,000216351405
EVD5X61M24A*80VSL1102122B*17.512.58.525,000216351277
EVD5X61M24A*96VTN1002122B*17.512.58.524,800216351453
EVD5X61M24A*97VTN1002122A*17.512.58.524,800216351525
EVD5X61M21A*80MSU0802120A*17.513.08.524,400216351036
EVD5X61M24A*80VTL1102122B*17.512.58.524,800216351325
EVD5X61M21A*96VTN1002122B*17.512.58.524,600216351205
EVD5X61M21A*80VSL1102122B*17.512.58.524,800216351020
EVD5X61M21A*80MSU1002120A*17.512.58.525,000216351044
EVD5X61M21A*95MSU1002122A*17.512.58.124,400216351165
EVD5X49M24A*80MSU0802120A*17.512.58.124,600216350572
EVM5X60M21A*80MSU0802120A*17.512.58.124,400216350020
EVM5X60M21A*96VTN1002122B*17.512.58.124,400216350188
EVD5X60M21A*96VTN1002122B*17.512.58.124,400216350932
EVD5X61M21A*80MSU0601716A*17.512.08.125,000216351028
EVD5X61M21A*80VTL1102122B*17.512.58.124,600216351084
EVM5X49M21A*80MSU0802120A*17.512.58.124,400216349764
EVD5X61M21A*+WALLCON*97CMN0802120B*17.512.58.023,800216351117
EVD5X61M21A*+WALLCON*97CMN1002122B*17.513.08.023,600216351125
EVD5X61M21A*+WALLCON*96CTN0802120B*17.512.58.023,800216351173
EVM5X49M21A*+WALLCON*95CSU1002122B*17.512.58.023,600216349820
EVD5X61M21A*+WALLCON*80CSU1002120B*17.513.08.023,600216351221
EVD5X61M21A*+WALLCON*97CTN0802120A*17.512.58.023,800216351229
EVD5X61M21A*+WALLCON*97CTN1002122A*17.513.08.023,600216351237
EVD5X61M24A*+WALLCON*97CMN1202422B*17.513.08.023,600216351357
EVD5X49M24A*+WALLCON*80CTL0902120B*17.512.58.023,400216350580
EVD5X49M24A*+WALLCON*96CTN1202422B*17.512.58.023,400216350668
EVD5X61M24A*+WALLCON*96CTN0802120B*17.512.58.023,600216351413
EVD5X61M24A*+WALLCON*80CTL0702120B*17.512.58.023,800216351293
EVM5X49M21A*+WALLCON*96CTN1002122B*17.512.58.023,600216349900
EVM5X49M21A*+WALLCON*80CSU0802120B*17.513.08.023,400216349932
EVD5X49M24A*+WALLCON*97CTN1202422A*17.512.58.023,400216350708
EVM5X49M21A*+WALLCON*80CSU1002120B*17.512.58.023,600216349940
EVM5X49M21A*+WALLCON*97CTN1002122A*17.512.58.023,600216349956
EVM5X60M21A*+WALLCON*80CSU1002120A*17.512.08.025,200216349988
EVD5X60M21A*80MSU0802120A*17.512.58.024,400216350772
EVD5X60M21A*+WALLCON*80CSU1002120A*17.512.08.025,200216350740
EVM5X60M21A*+WALLCON*80CTL0902120B*17.512.58.023,600216350044
EVM5X60M21A*+WALLCON*80CTL1102120B*17.512.58.023,600216350052
EVM5X60M21A*+WALLCON*95CSU1002122B*17.512.58.023,600216350084
EVD5X61M24A*+WALLCON*97CTN0802120A*17.512.58.023,600216351485
EVD5X60M21A*+WALLCON*80CTL0902120B*17.512.58.023,600216350796
EVD5X60M21A*+WALLCON*80CTL1102120B*17.512.58.023,600216350804
EVD5X60M21A*+WALLCON*95CSU1002122B*17.512.58.023,400216350836
EVM5X60M21A*+WALLCON*96CTN1002122B*17.512.58.023,600216350164
Yearly running cost in 10 large cities$1,258-$3,646

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Kenmore (C,H,T)5H8T48*K*AAA?
The Kenmore (C,H,T)5H8T48*K*AAA is rated at up to 18.0 SEER2 and 13.5 EER2 for cooling and up to 8.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 413 certified matchups SEER2 ranges from 15.2-18.0.
Is the Kenmore (C,H,T)5H8T48*K*AAA good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 4-ton model.
How much does the Kenmore (C,H,T)5H8T48*K*AAA cost to run per year?
At its rated efficiency it costs about $1,258-$3,646 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,589 in Phoenix and $3,076 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Kenmore (C,H,T)5H8T48*K*AAA?
ENERGY STAR lists 413 certified combinations for this outdoor unit. The highest-rated ones use FTMA5B60L0D, EVD5X61M21A*+WALLCON, EVD5X61M24A*+WALLCON.
What refrigerant does the Kenmore (C,H,T)5H8T48*K*AAA use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,597/yrYou save $910/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Kenmore (C,H,T)5H8T48*K*AAA
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,597
Current system, per year
$2,508
You save per year
$910
Payback
19.8 years
Net after 10 years
-$8,898

Cooling $939Heating $659Electricity used: 9,984 kWhSaved vs. a minimum-efficiency heat pump: $331

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 4 ton models

See all 319 4 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of June 29, 2026. How we use the data.