4-ton central heat pump · HSA19 Series
Century HSA1960V1-**A
Average cooling efficiency and below average heating efficiency for a 4-ton central heat pump, but not rated for cold climates.
Ranks #113 of 319 4 ton central heat pumps for cooling efficiency, and costs about $1,467 a year to run in a mixed climate like Atlanta.
- SEER2
- 18.0 Cooling efficiency over a seasonAverage · beats 66%
- HSPF2
- 8.2 Heating efficiency over a seasonBelow average · beats 28%
- EER2
- 11.2 Cooling efficiency on a 95°F dayBelow average · beats 28%
- Heat at 5°F
- 29,600 BTU/h50% of its 47°F outputAverage · beats 51%
A good fit if…
- You want steady temperatures and quiet running - the compressor varies its speed.
- You want a choice of indoor units - 82 certified pairings.
Think twice if…
- You often see nights below 0°F - it is not cold-climate certified.
- You mainly need heat - its HSPF2 is below average for central heat pumps.
Details
Specifications
| General | |
|---|---|
| Brand | Century |
| Also sold as | Comfort-Aire |
| Outdoor unit model | HSA1960V1-**A |
| Series | HSA19 Series |
| Type | Central heat pump |
| Nominal size | 4 ton |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-454B |
| Connected (smart) capable | No |
| On the market since | June 3, 2025 |
| Last certified | May 27, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 18.0 (range 16.5-18.0) |
| EER2Efficiency at 95°F outdoors | 11.0-11.7 |
| Cooling capacity | 46,000-48,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 7.8-8.2 |
| Capacity at 47°F | 45,500-48,000 BTU/h |
| Capacity at 17°F | 27,800-30,200 BTU/h |
| Capacity at 5°F | 21,800-29,600 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.80-2.06 |
| ENERGY STAR cold climate | No |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with 7E[C,U]50/60CX-**+TDR at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 82 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | Furnace | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|---|
| 7E[C,U]50/60CX-**+TDR | GUH80C110C5MP | 18.0 | 11.2 | 8.2 | 23,600 | 217504094 |
| 7E[C,U]50/60CX-**+TDR | GUH92C090C4MP | 18.0 | 11.2 | 8.2 | 23,400 | 217504096 |
| 7E[C,U]50/60CX-**+TDR | GUH96C090C4MP | 18.0 | 11.2 | 8.2 | 23,400 | 217504102 |
| 7E[C,U]50/60CX-**+TDR | GUH80C090B4MP | 18.0 | 11.5 | 8.2 | 23,400 | 217504208 |
| 7E[C,U]50/60CX-**+TDR | GUH80C110C5MP | 18.0 | 11.2 | 8.2 | 23,600 | 217504512 |
| 7E[C,U]50/60CX-**+TDR | GUH92C090C4MP | 18.0 | 11.2 | 8.2 | 23,400 | 217504513 |
| 7E[C,U]50/60CX-**+TDR | GUH96C090C4MP | 18.0 | 11.2 | 8.2 | 23,400 | 217504518 |
| 7E[C,U]50/60CX-**+TDR | GUH80C090B4MP | 18.0 | 11.5 | 8.2 | 23,400 | 217504603 |
| 7ED50/60CX-**+TDR | GDD92C090C4MP | 18.0 | 11.2 | 8.0 | 29,400 | 217504236 |
| 7ED50/60CX-**+TDR | GDD80C110C5MP | 18.0 | 11.7 | 8.0 | 28,800 | 217504628 |
| 7ED50/60CX-**+TDR | GDD92C090C4MP | 18.0 | 11.2 | 8.0 | 29,400 | 217504630 |
| 7ED50/60CX-**+TDR | GDD80C110C5MP | 18.0 | 11.7 | 8.0 | 28,800 | 217504235 |
| 7E[C,U]48BX-**+TDR | GUH80C090B4MP | 18.0 | 11.7 | 7.8 | 22,000 | 217504148 |
| 7E[C,U]48CX-**+TDR | GUH80C110C5MP | 18.0 | 11.5 | 7.8 | 22,200 | 217504114 |
| 7E[C,U]48CX-**+TDR | GUH92C090C4MP | 18.0 | 11.5 | 7.8 | 22,000 | 217504116 |
| 7E[C,U]48CX-**+TDR | GUH92C110C4MP | 18.0 | 11.5 | 7.8 | 22,000 | 217504119 |
| 7E[C,U]48CX-**+TDR | GUH96C090C4MP | 18.0 | 11.5 | 7.8 | 22,000 | 217504123 |
| 7E[C,U]48CX-**+TDR | GUH80C090B4MP | 18.0 | 11.7 | 7.8 | 22,000 | 217504213 |
| 7E[C,U]48CX-**+TDR | GUH80C110C5MP | 18.0 | 11.5 | 7.8 | 22,200 | 217504529 |
| 7E[C,U]48CX-**+TDR | GUH92C090C4MP | 18.0 | 11.5 | 7.8 | 22,000 | 217504531 |
| 7E[C,U]48CX-**+TDR | GUH92C110C4MP | 18.0 | 11.5 | 7.8 | 22,000 | 217504532 |
| 7E[C,U]48CX-**+TDR | GUH96C090C4MP | 18.0 | 11.5 | 7.8 | 22,000 | 217504535 |
| 7E[C,U]48BX-**+TDR | GUH80C090B4MP | 18.0 | 11.7 | 7.8 | 22,000 | 217504554 |
| 7E[C,U]48CX-**+TDR | GUH80C090B4MP | 18.0 | 11.7 | 7.8 | 22,000 | 217504608 |
| 7E[C,U]50/60CX-**+TDR | GUH97T090C3MP | 18.0 | 11.2 | 7.8 | 23,200 | 217547461 |
| 7E[C,U]50/60CX-**+TDR | GUH97T090C5MP* | 18.0 | 11.2 | 7.8 | 23,800 | 217547462 |
| 7E[C,U]50/60CX-**+TDR | GUH97T090C3MP | 18.0 | 11.2 | 7.8 | 23,200 | 217547488 |
| 7E[C,U]50/60CX-**+TDR | GUH97T090C5MP* | 18.0 | 11.2 | 7.8 | 23,800 | 217547489 |
| HMA48CX1*- | - | 18.0 | 11.7 | 7.8 | 23,400 | 217662744 |
| HMA48CX1*- | - | 18.0 | 11.7 | 7.8 | 23,400 | 217662747 |
| 7E[C,U]50/60CX-**+TDR | GUH80X100C5MP | 17.5 | 11.0 | 8.2 | 23,800 | 217504090 |
| 7E[C,U]50/60CX-**+TDR | GUH92C110C4MP | 17.5 | 11.5 | 8.2 | 23,400 | 217504098 |
| 7E[C,U]50/60CX-**+TDR | GUH92C110C5MP | 17.5 | 11.2 | 8.2 | 23,600 | 217504100 |
| 7EH51CX-**+TDR | GUH92C110C4MP | 17.5 | 11.2 | 8.2 | 28,600 | 217504223 |
| 7EH51CX-**+TDR | GUH80C110C5MP | 17.5 | 11.2 | 8.2 | 29,000 | 217504219 |
| 7E[C,U]50/60CX-**+TDR | GUH80X100C5MP | 17.5 | 11.0 | 8.2 | 23,800 | 217504509 |
| 7E[C,U]50/60CX-**+TDR | GUH92C110C4MP | 17.5 | 11.5 | 8.2 | 23,400 | 217504515 |
| 7E[C,U]50/60CX-**+TDR | GUH92C110C5MP | 17.5 | 11.2 | 8.2 | 23,600 | 217504517 |
| 7EH51CX-**+TDR | GUH80C110C5MP | 17.5 | 11.2 | 8.2 | 29,000 | 217504613 |
| 7EH51CX-**+TDR | GUH92C110C4MP | 17.5 | 11.2 | 8.2 | 28,600 | 217504617 |
| 7EH51CX-**+TDR | GUH97T110C5MP | 17.5 | 11.2 | 8.1 | 29,000 | 217504231 |
| 7EH51CX-**+TDR | - | 17.5 | 11.0 | 8.1 | 29,000 | 217504388 |
| 7EH51CX-**+TDR | GUH97T110C5MP | 17.5 | 11.2 | 8.1 | 29,000 | 217504624 |
| 7EH51CX-**+TDR | - | 17.5 | 11.0 | 8.1 | 29,000 | 217504761 |
| 7E[C,U]50/60CX-**+TDR | GUH97T110C5MP | 17.5 | 11.2 | 8.0 | 23,600 | 217504106 |
| 7E[C,U]50/60CX-**+TDR | GUH97T110C5MP | 17.5 | 11.2 | 8.0 | 23,600 | 217504522 |
| 7EH51CX-**+TDR | GUH97T090C5MP* | 17.5 | 11.0 | 8.0 | 29,200 | 217547468 |
| 7EH51CX-**+TDR | GUH97T090C5MP* | 17.5 | 11.0 | 8.0 | 29,200 | 217547495 |
| 7E[C,U]48CX-**+TDR | GUH80X100C5MP | 17.5 | 11.2 | 7.8 | 22,400 | 217504110 |
| 7EH48CX-**+TDR | GUH80C090C5MP | 17.5 | 11.2 | 7.8 | 23,800 | 217504131 |
| 7EH48CX-**+TDR | GUH80C110C5MP | 17.5 | 11.5 | 7.8 | 23,600 | 217504134 |
| 7E[C,U]48CX-**+TDR | GUH80X100C5MP | 17.5 | 11.2 | 7.8 | 22,400 | 217504527 |
| 7EH48CX-**+TDR | GUH80C090C5MP | 17.5 | 11.2 | 7.8 | 23,800 | 217504541 |
| 7EH48CX-**+TDR | GUH80C110C5MP | 17.5 | 11.5 | 7.8 | 23,600 | 217504543 |
| 7E[C,U]50/60CX-**+TDR | GUH96C110C5MP | 17.0 | 11.5 | 8.2 | 23,400 | 217504104 |
| 7E[C,U]50/60CX-**+TDR | GUH80C090C5MP | 17.0 | 11.5 | 8.2 | 23,200 | 217504092 |
| 7EH51CX-**+TDR | GUH80C090C5MP | 17.0 | 11.2 | 8.2 | 28,600 | 217504217 |
| 7EH51CX-**+TDR | GUH92C090C4MP | 17.0 | 11.0 | 8.2 | 28,800 | 217504221 |
| 7EH51CX-**+TDR | GUH92C110C5MP | 17.0 | 11.0 | 8.2 | 29,000 | 217504225 |
| 7EH51CX-**+TDR | GUH96C090C4MP | 17.0 | 11.0 | 8.2 | 28,800 | 217504228 |
Yearly running cost in 10 large cities
- Phoenix, AZ$1,566/yr
- Miami, FL$1,244/yr
- Houston, TX$1,405/yr
- Atlanta, GA$1,467/yr
- Los Angeles, CA$1,438/yr
- New York, NY$3,562/yr
- Chicago, IL$2,903/yr
- Denver, CO$2,422/yr
- Seattle, WA$1,495/yr
- Minneapolis, MN$3,001/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the Century HSA1960V1-**A?
- The Century HSA1960V1-**A is rated at up to 18.0 SEER2 and 11.2 EER2 for cooling and up to 8.2 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 82 certified matchups SEER2 ranges from 16.5-18.0.
- Is the Century HSA1960V1-**A good for cold climates?
- It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 4-ton model.
- How much does the Century HSA1960V1-**A cost to run per year?
- At its rated efficiency it costs about $1,244-$3,562 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,566 in Phoenix and $3,001 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the Century HSA1960V1-**A?
- ENERGY STAR lists 82 certified combinations for this outdoor unit. The highest-rated ones use 7E[C,U]50/60CX-**+TDR, 7ED50/60CX-**+TDR, 7E[C,U]48BX-**+TDR.
- What refrigerant does the Century HSA1960V1-**A use?
- It uses R-454B.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 4 ton models
- WeatherMaker PH8TAN548**AB18.0 SEER2 · 8.5 HSPF2
- MDV MOX630-48HFN8-M3F · cold climate17.8 SEER2 · 8.7 HSPF2
- Trane 4TWV8X60A1 · cold climate18.0 SEER2 · 8.5 HSPF2
- UTL UCHA-48HDCSN2 · cold climate17.5 SEER2 · 9.8 HSPF2
- Trane 4TWV8X48A118.0 SEER2 · 8.5 HSPF2
- UTL UCHA-48HDCSN4 · cold climate17.5 SEER2 · 9.8 HSPF2
- Tempstar T5H8T48*K*AAA18.0 SEER2 · 8.5 HSPF2
- VillaTherm VHPSD-UCHA-48HDCSN · cold climate17.5 SEER2 · 9.8 HSPF2
See all 319 4 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of May 27, 2026. How we use the data.