18,000 BTU mini-split heat pump · P-Series
Mitsubishi Electric PUZ-A18NKA8
Very good cooling efficiency and below average heating efficiency for a 18,000 BTU mini-split heat pump, but not rated for cold climates.
Ranks #45 of 465 18,000 BTU mini-splits for cooling efficiency, and costs about $555 a year to run in a mixed climate like Atlanta.
- SEER2
- 25.0 Cooling efficiency over a seasonVery good · beats 83%
- HSPF2
- 9.2 Heating efficiency over a seasonBelow average · beats 16%
- EER2
- 14.4 Cooling efficiency on a 95°F dayVery good · beats 87%
- Heat at 5°F
- 7,600 BTU/h27% of its 47°F outputBelow average · beats 0%
A good fit if…
- You want low cooling bills - its SEER2 beats 83% of mini-splits.
- You want steady temperatures and quiet running - the compressor varies its speed.
Think twice if…
- You often see nights below 0°F - it is not cold-climate certified.
- You mainly need heat - its HSPF2 is below average for mini-splits.
- You want the newest refrigerant - it uses R-410A, which is being phased down.
Details
Specifications
| General | |
|---|---|
| Brand | Mitsubishi Electric |
| Also sold as | Trane / Mitsubishi Electric |
| Outdoor unit model | PUZ-A18NKA8 |
| Series | P-Series |
| Type | Mini-split heat pump |
| Nominal size | 18,000 BTU |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-410A |
| Connected (smart) capable | No |
| On the market since | December 1, 2022 |
| Last certified | May 6, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 25.0 (range 20.3-25.0) |
| EER2Efficiency at 95°F outdoors | 11.4-14.4 |
| Cooling capacity | 18,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 9.0-9.2 |
| Capacity at 47°F | 23,000 BTU/h |
| Capacity at 17°F | 11,000-12,000 BTU/h |
| Capacity at 5°F | 6,200-7,600 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.52-1.68 |
| ENERGY STAR cold climate | No |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with PLA-A18EA at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|
| PLA-A18EA | 25.0 | 14.4 | 9.2 | 6,200 | 213249016 |
| TPLA0A0181EA Trane / Mitsubishi Electric | 25.0 | 14.4 | 9.2 | 6,200 | 213307619 |
| PVA-A18AA | 20.3 | 11.4 | 9.0 | 7,600 | 213249017 |
Yearly running cost in 10 large cities
- Phoenix, AZ$500/yr
- Miami, FL$347/yr
- Houston, TX$451/yr
- Atlanta, GA$555/yr
- Los Angeles, CA$563/yr
- New York, NY$1,450/yr
- Chicago, IL$1,201/yr
- Denver, CO$1,017/yr
- Seattle, WA$640/yr
- Minneapolis, MN$1,267/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the Mitsubishi Electric PUZ-A18NKA8?
- The Mitsubishi Electric PUZ-A18NKA8 is rated at up to 25.0 SEER2 and 14.4 EER2 for cooling and up to 9.2 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 3 certified matchups SEER2 ranges from 20.3-25.0.
- Is the Mitsubishi Electric PUZ-A18NKA8 good for cold climates?
- It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 18,000 BTU model.
- How much does the Mitsubishi Electric PUZ-A18NKA8 cost to run per year?
- At its rated efficiency it costs about $347-$1,450 a year in electricity in large U.S. cities, depending on climate and local rates - for example $500 in Phoenix and $1,267 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the Mitsubishi Electric PUZ-A18NKA8?
- ENERGY STAR lists 3 certified combinations for this outdoor unit. The highest-rated ones use PLA-A18EA, Trane / Mitsubishi Electric TPLA0A0181EA, PVA-A18AA.
- What refrigerant does the Mitsubishi Electric PUZ-A18NKA8 use?
- It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 18,000 BTU models
- Trane / Mitsubishi Electric TRUZA0181KA8025.0 SEER2 · 9.2 HSPF2
- TCL TMH18HDI2NAO0U25 · cold climate25.0 SEER2 · 10.0 HSPF2
- TCL H18FMH24XQC · cold climate25.0 SEER2 · 10.0 HSPF2
- DELLA 048-TCQ-MODU-1D2 · cold climate25.0 SEER2 · 10.0 HSPF2
- Kenmore D5CPRAH18AA · cold climate24.5 SEER2 · 15.2 HSPF2
- AUX AMAR18HP230V1CO · cold climate25.0 SEER2 · 10.2 HSPF2
- Fujitsu AOUH18KUAH1 · cold climate24.5 SEER2 · 11.4 HSPF2
- MDV M3OD31-18HFN10-M1X-D · cold climate25.0 SEER2 · 10.4 HSPF2
See all 465 18,000 BTU mini-splits, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of May 6, 2026. How we use the data.