HVAC Rated

18,000 BTU mini-split heat pump · free matcht 24S R32

TCL H18FMH24XQC

Very good cooling efficiency and average heating efficiency for a 18,000 BTU mini-split heat pump, and certified for cold climates.

Ranks #42 of 465 18,000 BTU mini-splits for cooling efficiency, and costs about $439 a year to run in a mixed climate like Atlanta.

SEER2
25.0 Cooling efficiency over a season
Very good · beats 83%
HSPF2
10.0 Heating efficiency over a season
Average · beats 43%
EER2
11.7 Cooling efficiency on a 95°F day
Below average · beats 16%
Heat at 5°F
14,000 BTU/h78% of its 47°F output
Average · beats 48%

A good fit if…

  • You want low cooling bills - its SEER2 beats 83% of mini-splits.
  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 14,000 BTU/h at 5°F.
  • You want steady temperatures and quiet running - the compressor varies its speed.

Think twice if…

  • Nothing stands out - its ratings have no weak spot for its class.

Calculate my running cost

Details

Specifications18,000 BTU, R-32
General
BrandTCL
Also sold asZERO, iFFALCON, Cozeware, ALBOTT
Outdoor unit modelH18FMH24XQC
Seriesfree matcht 24S R32
TypeMini-split heat pump
Nominal size18,000 BTU
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-32
Connected (smart) capableNo
On the market sinceApril 16, 2026
Last certifiedAugust 20, 2026
Cooling
SEER2Seasonal efficiency, higher is better25.0 (range 25.0)
EER2Efficiency at 95°F outdoors11.7
Cooling capacity18,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better10.0
Capacity at 47°F18,000 BTU/h
Capacity at 17°F14,000 BTU/h
Capacity at 5°F14,000 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.00
ENERGY STAR cold climateYes
Heating output as it gets colder78% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its best matchup at the standard test temperatures, in BTU/h:

Certified matchups1 indoor units

The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitSEER2EER2HSPF2Heat @5°FAHRI ref.
- · cold climate25.011.710.014,000218451113
Same unit, other model numbers5

These model numbers have exactly the same certified ratings and matchups as the TCL H18FMH24XQC: the same equipment under another brand, or a variant code for voltage, colour or market. Everything on this page applies to them.

Yearly running cost in 10 large cities$341-$1,092

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the TCL H18FMH24XQC?
The TCL H18FMH24XQC is rated at up to 25.0 SEER2 and 11.7 EER2 for cooling and up to 10.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with.
Is the TCL H18FMH24XQC good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 14,000 BTU/h at 5°F with a COP of 2.00, so it is still 2.0 times as efficient as electric resistance heat at that temperature.
How much does the TCL H18FMH24XQC cost to run per year?
At its rated efficiency it costs about $341-$1,092 a year in electricity in large U.S. cities, depending on climate and local rates - for example $446 in Phoenix and $932 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Is the TCL H18FMH24XQC the same as the TCL TMH18HDI2NAO0U?
Yes, as far as the certified ratings go. ENERGY STAR lists 6 model numbers with identical efficiency, capacity and matchups, which means the same outdoor unit sold under a different brand or with a minor variant code (voltage, colour or region). The full list is on this page.
What refrigerant does the TCL H18FMH24XQC use?
It uses R-32.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $455/yrYou save $473/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump TCL H18FMH24XQC
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$455
Current system, per year
$928
You save per year
$473
Payback
14.8 years
Net after 10 years
-$2,269

Cooling $253Heating $202Electricity used: 2,844 kWhSaved vs. a minimum-efficiency heat pump: $257

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 18,000 BTU models

See all 465 18,000 BTU mini-splits, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of August 20, 2026. How we use the data.