HVAC Rated

24,000 BTU mini-split heat pump · M series

Mitsubishi Electric SUZ-AA24NL

Below average cooling efficiency and average heating efficiency for a 24,000 BTU mini-split heat pump, but not rated for cold climates.

Ranks #257 of 430 24,000 BTU mini-splits for cooling efficiency, and costs about $636 a year to run in a mixed climate like Atlanta.

SEER2
21.2 Cooling efficiency over a season
Below average · beats 35%
HSPF2
10.0 Heating efficiency over a season
Average · beats 43%
EER2
12.2 Cooling efficiency on a 95°F day
Below average · beats 33%
Heat at 5°F
14,000 BTU/h56% of its 47°F output
Excellent · beats 100%

A good fit if…

  • You want steady temperatures and quiet running - the compressor varies its speed.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • Cooling cost matters most - its SEER2 is below average for mini-splits.

Calculate my running cost

Details

Specifications24,000 BTU, R-454B
General
BrandMitsubishi Electric
Outdoor unit modelSUZ-AA24NL
SeriesM series
TypeMini-split heat pump
Nominal size24,000 BTU
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceFebruary 3, 2025
Last certifiedJuly 29, 2025
Cooling
SEER2Seasonal efficiency, higher is better21.2 (range 19.5-21.2)
EER2Efficiency at 95°F outdoors11.8-12.2
Cooling capacity22,800-24,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better9.4-10.0
Capacity at 47°F25,000 BTU/h
Capacity at 17°F17,100 BTU/h
Capacity at 5°F13,900-14,000 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater3.00
ENERGY STAR cold climateNo
Heating output as it gets colder56% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with PEAD-AA24NL at the standard test temperatures, in BTU/h:

Certified matchups2 indoor units

The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitSEER2EER2HSPF2Heat @5°FAHRI ref.
PEAD-AA24NL21.212.210.013,900215734904
SVZ-AP24NL19.511.89.414,000215734905
Yearly running cost in 10 large cities$534-$1,549

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Mitsubishi Electric SUZ-AA24NL?
The Mitsubishi Electric SUZ-AA24NL is rated at up to 21.2 SEER2 and 12.2 EER2 for cooling and up to 10.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 2 certified matchups SEER2 ranges from 19.5-21.2.
Is the Mitsubishi Electric SUZ-AA24NL good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 24,000 BTU model.
How much does the Mitsubishi Electric SUZ-AA24NL cost to run per year?
At its rated efficiency it costs about $534-$1,549 a year in electricity in large U.S. cities, depending on climate and local rates - for example $675 in Phoenix and $1,307 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Mitsubishi Electric SUZ-AA24NL?
ENERGY STAR lists 2 certified combinations for this outdoor unit. The highest-rated ones use PEAD-AA24NL, SVZ-AP24NL.
What refrigerant does the Mitsubishi Electric SUZ-AA24NL use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $678/yrYou save $575/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Mitsubishi Electric SUZ-AA24NL
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$678
Current system, per year
$1,254
You save per year
$575
Payback
15.6 years
Net after 10 years
-$3,246

Cooling $398Heating $280Electricity used: 4,241 kWhSaved vs. a minimum-efficiency heat pump: $286

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 24,000 BTU models

See all 430 24,000 BTU mini-splits, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of July 29, 2025. How we use the data.