2-ton central heat pump · MHP170 SERIES
MRCOOL MHP17024A-**A
Average cooling efficiency and below average heating efficiency for a 2-ton central heat pump, but not rated for cold climates.
Ranks #240 of 331 2 ton central heat pumps for cooling efficiency, and costs about $717 a year to run in a mixed climate like Atlanta.
- SEER2
- 17.0 Cooling efficiency over a seasonAverage · beats 49%
- HSPF2
- 8.0 Heating efficiency over a seasonBelow average · beats 12%
- EER2
- 14.0 Cooling efficiency on a 95°F dayExcellent · beats 98%
- Heat at 5°F
- 10,800 BTU/h48% of its 47°F outputAverage · beats 67%
A good fit if…
- You want a choice of indoor units - 22 certified pairings.
Think twice if…
- You often see nights below 0°F - it is not cold-climate certified.
- You mainly need heat - its HSPF2 is below average for central heat pumps.
- You want the newest refrigerant - it uses R-410A, which is being phased down.
- Comfort and noise matter - a single-stage compressor runs only full-on or off.
Details
Specifications
| General | |
|---|---|
| Brand | MRCOOL |
| Outdoor unit model | MHP17024A-**A |
| Series | MHP170 SERIES |
| Type | Central heat pump |
| Nominal size | 2 ton |
| CompressorVariable-speed units run longer at low power | Single stage |
| Refrigerant | R-410A |
| Connected (smart) capable | No |
| On the market since | October 25, 2022 |
| Last certified | October 27, 2025 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 17.0 (range 15.6-17.0) |
| EER2Efficiency at 95°F outdoors | 12.5-14.0 |
| Cooling capacity | 22,600-23,800 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 7.8-8.0 |
| Capacity at 47°F | 21,200-22,000 BTU/h |
| Capacity at 17°F | 13,400-14,000 BTU/h |
| Capacity at 5°F | 10,200-10,800 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 2.00-2.14 |
| ENERGY STAR cold climate | No |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with MCHP30BNPA*+TDR+TXV at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit and furnace. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | Furnace | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|---|
| MCHP30BNPA*+TDR+TXV | MGM80SE090B4A | 17.0 | 14.0 | 8.0 | 10,400 | 211735228 |
| MCVP30ANPA+TDR+TXV | MGM80SE090B4A | 16.6 | 13.5 | 8.0 | 10,400 | 210326175 |
| MCVP30BNPA+TDR+TXV | MGM80SE090B4A | 16.6 | 13.5 | 8.0 | 10,400 | 210441056 |
| MCHP30ANPA*+TDR+TXV | MGM80SE070B3A | 16.4 | 13.5 | 8.0 | 10,400 | 211735083 |
| MCHP30ANPA*+TDR+TXV | MGM80SE045A3A | 16.4 | 13.5 | 8.0 | 10,200 | 211735069 |
| MCHP24ANPA*+TDR+TXV | MGM80SE070B3A | 16.4 | 13.5 | 7.8 | 10,400 | 211734979 |
| MCVP24ANPA+TDR+TXV | MGM80SE090B4A | 16.4 | 13.5 | 7.8 | 10,400 | 210326163 |
| MCVP24BNPA+TDR+TXV | MGM80SE090B4A | 16.4 | 13.5 | 7.8 | 10,400 | 210441052 |
| MCVP30ANPA+TDR+TXV | MGM80SE070B3A | 16.2 | 13.5 | 7.8 | 10,400 | 210326169 |
| MCVP30ANPA+TDR+TXV | MGM80SE045A3A | 16.2 | 13.5 | 7.8 | 10,200 | 210326167 |
| MCVP24ANPA+TDR+TXV | MGM80SE070B3A | 16.2 | 13.0 | 7.8 | 10,400 | 210326155 |
| MCHP24ANPA*+TDR+TXV | MGM80SE045A3A | 16.2 | 13.5 | 7.8 | 10,200 | 211734965 |
| MCHP30BNPA*+TDR+TXV | MGM96SE045B3XA | 16.0 | 13.0 | 7.8 | 10,800 | 211735303 |
| MCHP30BNPA*+TDR+TXV | MGM96SE070B3XA | 16.0 | 13.0 | 7.8 | 10,800 | 211735320 |
| MCVP24BNPA+TDR+TXV | MGM96SE045B3XA | 15.6 | 12.5 | 7.8 | 10,800 | 210441053 |
| MCVP24BNPA+TDR+TXV | MGM96SE070B3XA | 15.6 | 12.5 | 7.8 | 10,800 | 210441054 |
| MCVP24ANPA+TDR+TXV | MGM96SE070B3XA | 15.6 | 12.5 | 7.8 | 10,800 | 210326161 |
| MCVP24ANPA+TDR+TXV | MGM96SE045B3XA | 15.6 | 12.5 | 7.8 | 10,800 | 210326159 |
| MCVP30ANPA+TDR+TXV | MGM96SE070B3XA | 15.6 | 13.0 | 7.8 | 10,600 | 210326173 |
| MCVP30ANPA+TDR+TXV | MGM96SE045B3XA | 15.6 | 13.0 | 7.8 | 10,600 | 210326171 |
| MCVP30BNPA+TDR+TXV | MGM96SE045B3XA | 15.6 | 13.0 | 7.8 | 10,600 | 210441057 |
| MCVP30BNPA+TDR+TXV | MGM96SE070B3XA | 15.6 | 13.0 | 7.8 | 10,600 | 210441058 |
Yearly running cost in 10 large cities
- Phoenix, AZ$794/yr
- Miami, FL$647/yr
- Houston, TX$712/yr
- Atlanta, GA$717/yr
- Los Angeles, CA$697/yr
- New York, NY$1,710/yr
- Chicago, IL$1,388/yr
- Denver, CO$1,153/yr
- Seattle, WA$708/yr
- Minneapolis, MN$1,427/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the MRCOOL MHP17024A-**A?
- The MRCOOL MHP17024A-**A is rated at up to 17.0 SEER2 and 14.0 EER2 for cooling and up to 8.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 22 certified matchups SEER2 ranges from 15.6-17.0.
- Is the MRCOOL MHP17024A-**A good for cold climates?
- It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 2-ton model.
- How much does the MRCOOL MHP17024A-**A cost to run per year?
- At its rated efficiency it costs about $647-$1,710 a year in electricity in large U.S. cities, depending on climate and local rates - for example $794 in Phoenix and $1,427 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the MRCOOL MHP17024A-**A?
- ENERGY STAR lists 22 certified combinations for this outdoor unit. The highest-rated ones use MCHP30BNPA*+TDR+TXV, MCVP30ANPA+TDR+TXV, MCVP30BNPA+TDR+TXV.
- What refrigerant does the MRCOOL MHP17024A-**A use?
- It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 2 ton models
- Trane 5TWX6024A117.0 SEER2 · 8.1 HSPF2
- WeatherMaker PH7TAN424**AA17.0 SEER2 · 7.8 HSPF2
- Trane 5TWR6024A117.0 SEER2 · 8.1 HSPF2
- Ducane 7SHP15V24P-**A · cold climate16.9 SEER2 · 8.9 HSPF2
- Lennox ML17XP1-024-230A17.0 SEER2 · 8.2 HSPF2
- GE Appliances NS15H24HA5 · cold climate16.9 SEER2 · 8.9 HSPF2
- Lennox EL17XP1-024-230A17.0 SEER2 · 8.2 HSPF2
- Lennox ML15KSPV-024-230A · cold climate16.8 SEER2 · 8.9 HSPF2
See all 331 2 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of October 27, 2025. How we use the data.