2-ton central heat pump · MVP-series
MRCOOL MVP-24-HP-C-230-25
Average cooling and heating efficiency for a 2-ton central heat pump, and certified for cold climates.
Ranks #245 of 331 2 ton central heat pumps for cooling efficiency, and costs about $719 a year to run in a mixed climate like Atlanta.
- SEER2
- 16.7 Cooling efficiency over a seasonAverage · beats 43%
- HSPF2
- 9.1 Heating efficiency over a seasonAverage · beats 60%
- EER2
- 11.7 Cooling efficiency on a 95°F dayAverage · beats 43%
- Heat at 5°F
- 18,100 BTU/h75% of its 47°F outputVery good · beats 86%
A good fit if…
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 18,100 BTU/h at 5°F.
- You want steady temperatures and quiet running - the compressor varies its speed.
Think twice if…
- You want the newest refrigerant - it uses R-410A, which is being phased down.
Details
Specifications
| General | |
|---|---|
| Brand | MRCOOL |
| Outdoor unit model | MVP-24-HP-C-230-25 |
| Series | MVP-series |
| Type | Central heat pump |
| Nominal size | 2 ton |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-410A |
| Connected (smart) capable | No |
| On the market since | January 1, 2023 |
| Last certified | June 3, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 16.7 (range 16.7) |
| EER2Efficiency at 95°F outdoors | 11.7 |
| Cooling capacity | 24,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 9.1 |
| Capacity at 47°F | 24,000 BTU/h |
| Capacity at 17°F | 18,000 BTU/h |
| Capacity at 5°F | 18,100 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 2.29 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with MVP-24-HP-MUAH-230-25 at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|
| MVP-24-HP-MUAH-230-25 · cold climate | 16.7 | 11.7 | 9.1 | 18,100 | 211644118 |
Same unit, other model numbers
These model numbers have exactly the same certified ratings and matchups as the MRCOOL MVP-24-HP-C-230-25: the same equipment under another brand, or a variant code for voltage, colour or market. Everything on this page applies to them.
- MRCOOL CENTRAL-24-HP-C-23025
Yearly running cost in 10 large cities
- Phoenix, AZ$815/yr
- Miami, FL$674/yr
- Houston, TX$730/yr
- Atlanta, GA$719/yr
- Los Angeles, CA$695/yr
- New York, NY$1,693/yr
- Chicago, IL$1,370/yr
- Denver, CO$1,135/yr
- Seattle, WA$694/yr
- Minneapolis, MN$1,403/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the MRCOOL MVP-24-HP-C-230-25?
- The MRCOOL MVP-24-HP-C-230-25 is rated at up to 16.7 SEER2 and 11.7 EER2 for cooling and up to 9.1 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with.
- Is the MRCOOL MVP-24-HP-C-230-25 good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 18,100 BTU/h at 5°F with a COP of 2.29, so it is still 2.3 times as efficient as electric resistance heat at that temperature.
- How much does the MRCOOL MVP-24-HP-C-230-25 cost to run per year?
- At its rated efficiency it costs about $674-$1,693 a year in electricity in large U.S. cities, depending on climate and local rates - for example $815 in Phoenix and $1,403 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Is the MRCOOL MVP-24-HP-C-230-25 the same as the MRCOOL CENTRAL-24-HP-C-23025?
- Yes, as far as the certified ratings go. ENERGY STAR lists both model numbers with identical efficiency, capacity and matchups, which means the same outdoor unit sold under a different brand or with a minor variant code (voltage, colour or region). The full list is on this page.
- Which indoor units work with the MRCOOL MVP-24-HP-C-230-25?
- ENERGY STAR lists 1 certified combination for this outdoor unit. The highest-rated one uses MVP-24-HP-MUAH-230-25.
- What refrigerant does the MRCOOL MVP-24-HP-C-230-25 use?
- It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 2 ton models
- Lennox ML15KSPV-024-230A · cold climate16.8 SEER2 · 8.9 HSPF2
- MOOVAIR DMA24HOS20230E · cold climate16.5 SEER2 · 9.5 HSPF2
- GE Appliances NS15H24HA5 · cold climate16.9 SEER2 · 8.9 HSPF2
- Friedrich WFPU17Z243C · cold climate16.5 SEER2 · 9.0 HSPF2
- Ducane 7SHP15V24P-**A · cold climate16.9 SEER2 · 8.9 HSPF2
- Hisense AUWR-24U3SF2 · cold climate16.5 SEER2 · 9.0 HSPF2
- WeatherMaker PH7TAN424**AA17.0 SEER2 · 7.8 HSPF2
- MDV MOX330-24HFN8-M3 · cold climate16.5 SEER2 · 9.0 HSPF2
See all 331 2 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of June 3, 2026. How we use the data.