4-ton central heat pump · DYR Inverter Plus
Pioneer YH4248GHFD18R2
Average cooling efficiency and below average heating efficiency for a 4-ton central heat pump, and certified for cold climates.
Ranks #153 of 319 4 ton central heat pumps for cooling efficiency, and costs about $1,473 a year to run in a mixed climate like Atlanta.
- SEER2
- 17.5 Cooling efficiency over a seasonAverage · beats 58%
- HSPF2
- 8.5 Heating efficiency over a seasonBelow average · beats 38%
- EER2
- 10.1 Cooling efficiency on a 95°F dayBelow average · beats 14%
- Heat at 5°F
- 33,000 BTU/h69% of its 47°F outputBelow average · beats 20%
A good fit if…
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 33,000 BTU/h at 5°F.
- You want steady temperatures and quiet running - the compressor varies its speed.
Think twice if…
- You mainly need heat - its HSPF2 is below average for central heat pumps.
- You want the newest refrigerant - it uses R-410A, which is being phased down.
Details
Specifications
| General | |
|---|---|
| Brand | Pioneer |
| Also sold as | AIR-CON, DIAL |
| Outdoor unit model | YH4248GHFD18R2 |
| Series | DYR Inverter Plus |
| Type | Central heat pump |
| Nominal size | 4 ton |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-410A |
| Connected (smart) capable | No |
| On the market since | March 2, 2023 |
| Last certified | January 27, 2025 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 17.5 (range 17.5) |
| EER2Efficiency at 95°F outdoors | 10.1 |
| Cooling capacity | 48,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 8.5 |
| Capacity at 47°F | 48,000 BTU/h |
| Capacity at 17°F | 31,000 BTU/h |
| Capacity at 5°F | 33,000 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.90 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with DR048GHFD18HT2 at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|
| DR048GHFD18HT2 · cold climate | 17.5 | 10.1 | 8.5 | 33,000 | 207028597 |
Same unit, other model numbers
Yearly running cost in 10 large cities
- Phoenix, AZ$1,604/yr
- Miami, FL$1,290/yr
- Houston, TX$1,438/yr
- Atlanta, GA$1,473/yr
- Los Angeles, CA$1,438/yr
- New York, NY$3,544/yr
- Chicago, IL$2,882/yr
- Denver, CO$2,399/yr
- Seattle, WA$1,477/yr
- Minneapolis, MN$2,971/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the Pioneer YH4248GHFD18R2?
- The Pioneer YH4248GHFD18R2 is rated at up to 17.5 SEER2 and 10.1 EER2 for cooling and up to 8.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with.
- Is the Pioneer YH4248GHFD18R2 good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 33,000 BTU/h at 5°F with a COP of 1.90, so it is still 1.9 times as efficient as electric resistance heat at that temperature.
- How much does the Pioneer YH4248GHFD18R2 cost to run per year?
- At its rated efficiency it costs about $1,290-$3,544 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,604 in Phoenix and $2,971 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Is the Pioneer YH4248GHFD18R2 the same as the AIR-CON ASDDI4H4S48?
- Yes, as far as the certified ratings go. ENERGY STAR lists 3 model numbers with identical efficiency, capacity and matchups, which means the same outdoor unit sold under a different brand or with a minor variant code (voltage, colour or region). The full list is on this page.
- Which indoor units work with the Pioneer YH4248GHFD18R2?
- ENERGY STAR lists 1 certified combination for this outdoor unit. The highest-rated one uses DR048GHFD18HT2.
- What refrigerant does the Pioneer YH4248GHFD18R2 use?
- It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 4 ton models
- OLMO OS-EAH48-230VO · cold climate17.5 SEER2 · 8.5 HSPF2
- Armstrong Air 4SHP18LX160P17.5 SEER2 · 7.8 HSPF2
- Hisense AUWR-48U3SP2 · cold climate17.5 SEER2 · 8.6 HSPF2
- DuraSTAR DRU1H49S2A · cold climate17.1 SEER2 · 9.1 HSPF2
- Friedrich WFPU18Z483C · cold climate17.5 SEER2 · 8.6 HSPF2
- American Standard 5A6H7060A1 · cold climate17.1 SEER2 · 9.0 HSPF2
- Invertercool COH17S-60AD · cold climate17.5 SEER2 · 8.8 HSPF2
- Panasonic CU-HM55BAHU · cold climate17.1 SEER2 · 9.0 HSPF2
See all 319 4 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of January 27, 2025. How we use the data.