5-ton central heat pump · W Series
Rheem WP15AZ60AJ2N
Below average cooling and heating efficiency for a 5-ton central heat pump, and certified for cold climates.
Ranks #55 of 100 5 ton central heat pumps for cooling efficiency, and costs about $1,864 a year to run in a mixed climate like Atlanta.
- SEER2
- 16.0 Cooling efficiency over a seasonBelow average · beats 26%
- HSPF2
- 8.1 Heating efficiency over a seasonBelow average · beats 20%
- EER2
- 11.7 Cooling efficiency on a 95°F dayAverage · beats 43%
- Heat at 5°F
- 30,600 BTU/h54% of its 47°F outputVery good · beats 88%
A good fit if…
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 30,600 BTU/h at 5°F.
Think twice if…
- Cooling cost matters most - its SEER2 is below average for central heat pumps.
- You mainly need heat - its HSPF2 is below average for central heat pumps.
- You want the newest refrigerant - it uses R-410A, which is being phased down.
Details
Specifications
| General | |
|---|---|
| Brand | Rheem |
| Also sold as | Ruud, Fujitsu, WeatherKing |
| Outdoor unit model | WP15AZ60AJ2N |
| Series | W Series |
| Type | Central heat pump |
| Nominal size | 5 ton |
| CompressorVariable-speed units run longer at low power | Two-stage |
| Refrigerant | R-410A |
| Connected (smart) capable | No |
| On the market since | March 2, 2023 |
| Last certified | June 3, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 16.0 (range 15.2-16.0) |
| EER2Efficiency at 95°F outdoors | 11.7 |
| Cooling capacity | 56,500-57,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 8.1 |
| Capacity at 47°F | 56,500-57,000 BTU/h |
| Capacity at 17°F | 37,400-38,500 BTU/h |
| Capacity at 5°F | 29,600-30,600 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 2.20-2.30 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with FHRNTT6024S*ZTNA at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|
| FHRNTT6024S*ZTNA · cold climate | 16.0 | 11.7 | 8.1 | 30,600 | 211641691 |
| RH2TZ6024STANN · cold climate | 16.0 | 11.7 | 8.1 | 30,600 | 211627530 |
| RH2TZ6024STANN · cold climate | 16.0 | 11.7 | 8.1 | 30,600 | 211627531 |
| WH2TZ6024STANN · cold climate | 16.0 | 11.7 | 8.1 | 30,600 | 211627532 |
| WH2TZ6024STANN · cold climate | 16.0 | 11.7 | 8.1 | 30,600 | 213318043 |
| WH2TZ6024STANN · cold climate | 16.0 | 11.7 | 8.1 | 30,600 | 213318053 |
| RH3VZ6024STACN | 15.2 | 11.7 | 8.1 | 29,600 | 214664628 |
| RH3VZ6024STACN | 15.2 | 11.7 | 8.1 | 29,600 | 214664623 |
Yearly running cost in 10 large cities
- Phoenix, AZ$2,060/yr
- Miami, FL$1,674/yr
- Houston, TX$1,846/yr
- Atlanta, GA$1,864/yr
- Los Angeles, CA$1,813/yr
- New York, NY$4,451/yr
- Chicago, IL$3,613/yr
- Denver, CO$3,003/yr
- Seattle, WA$1,845/yr
- Minneapolis, MN$3,716/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the Rheem WP15AZ60AJ2N?
- The Rheem WP15AZ60AJ2N is rated at up to 16.0 SEER2 and 11.7 EER2 for cooling and up to 8.1 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 8 certified matchups SEER2 ranges from 15.2-16.0.
- Is the Rheem WP15AZ60AJ2N good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 30,600 BTU/h at 5°F with a COP of 2.30, so it is still 2.3 times as efficient as electric resistance heat at that temperature.
- How much does the Rheem WP15AZ60AJ2N cost to run per year?
- At its rated efficiency it costs about $1,674-$4,451 a year in electricity in large U.S. cities, depending on climate and local rates - for example $2,060 in Phoenix and $3,716 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the Rheem WP15AZ60AJ2N?
- ENERGY STAR lists 8 certified combinations for this outdoor unit. The highest-rated ones use FHRNTT6024S*ZTNA, RH2TZ6024STANN, WH2TZ6024STANN.
- What refrigerant does the Rheem WP15AZ60AJ2N use?
- It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 5 ton models
- Samsung AC060FCUDCG · cold climate16.0 SEER2 · 8.1 HSPF2
- Mainline MPP15AZ60AJ2N · cold climate16.0 SEER2 · 8.1 HSPF2
- Sure SP15AZ60AJ2N · cold climate16.0 SEER2 · 8.1 HSPF2
- LPS Legacy H4H7T60*K*AAA16.0 SEER2 · 8.1 HSPF2
- Thermal Zone TZPLAD1560AJN · cold climate16.0 SEER2 · 8.1 HSPF2
- Fujitsu FOP1560TJAZNA · cold climate16.0 SEER2 · 8.1 HSPF2
- York YH2F60TB2116.0 SEER2 · 8.1 HSPF2
- Friedrich FWP15AZ60AJ2N · cold climate16.0 SEER2 · 8.1 HSPF2
See all 100 5 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of June 3, 2026. How we use the data.