HVAC Rated

5-ton central heat pump · LX SERIES

York YH2F60TB21

Below average cooling and heating efficiency for a 5-ton central heat pump, but not rated for cold climates.

Ranks #59 of 100 5 ton central heat pumps for cooling efficiency, and costs about $1,840 a year to run in a mixed climate like Atlanta.

SEER2
16.0 Cooling efficiency over a season
Below average · beats 26%
HSPF2
8.1 Heating efficiency over a season
Below average · beats 20%
EER2
11.7 Cooling efficiency on a 95°F day
Average · beats 43%
Heat at 5°F
32,800 BTU/h53% of its 47°F output
Excellent · beats 97%

A good fit if…

  • You want a choice of indoor units - 177 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • Cooling cost matters most - its SEER2 is below average for central heat pumps.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.
  • You want the newest refrigerant - it uses R-410A, which is being phased down.

Calculate my running cost

Details

Specifications5 ton, R-410A
General
BrandYork
Outdoor unit modelYH2F60TB21
SeriesLX SERIES
TypeCentral heat pump
Nominal size5 ton
CompressorVariable-speed units run longer at low powerTwo-stage
RefrigerantR-410A
Connected (smart) capableNo
On the market sinceMay 18, 2023
Last certifiedAugust 12, 2026
Cooling
SEER2Seasonal efficiency, higher is better16.0 (range 15.2-16.0)
EER2Efficiency at 95°F outdoors11.0-12.0
Cooling capacity53,000-57,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8-8.1
Capacity at 47°F55,000-59,500 BTU/h
Capacity at 17°F37,400-39,000 BTU/h
Capacity at 5°F29,200-32,800 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.00-2.46
ENERGY STAR cold climateNo
Heating output as it gets colder53% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with XAHD60JBCN1 at the standard test temperatures, in BTU/h:

Certified matchups177 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 177 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
XAHD60JBCN1Y82E100C20LMPS116.011.78.131,200212413581
XAFD60JXXN1+JMET18DS2N1+TXV-16.011.78.130,600210338149
XAFD60HXXN1+JMVT20DC2N1+TXV-16.011.78.130,800210341455
XAFD60HXXN1+JMET18DS2N1+TXV-16.011.78.130,800210340718
XAFD60JXXN1+JMVT20DC2N1+TXV-16.011.78.130,800210338822
JHVTD60HBCC2N1-16.011.78.130,600210338003
JHETD60HBCS2N1-16.011.78.130,600210338004
JHETD60JBCS2N1-16.011.78.130,800210338151
JHVTD60JBCC2N1-16.011.78.130,600210338824
XAFD60JBCN1+JMET18DS2N1-16.011.78.130,600210338150
XAFD60HBCN1+JMVT20DC2N1-16.011.78.130,800210341456
XAFD60JBCN1+JMVT20DC2N1-16.011.78.130,800210338823
XAFD60HBCN1+JMET18DS2N1-16.011.78.130,800210340719
XAHD60JXXN1+TXVY81E100C16LMPS115.211.78.131,200212475127
XAFD60JBCN1Y81E120C16SMPS115.211.78.131,400212413593
XAHD60JXXN1+TXVY81E120C20LMPS115.211.78.131,200212475122
XAHD60JBCN1Y81E100C20SMPS115.211.78.131,200212413595
XAHD60JXXN1+TXVY81E080C20SMPS115.211.78.131,200212413598
XAFD60JXXN1+TXVY81E080C16LMPS115.211.78.131,400212475344
XAHD60JBCN1Y81E120C20SMPS115.211.78.131,200212413589
XAHD60JBCN1Y81E100C20LMPS115.211.78.131,200212475342
XAFD60JBCN1Y81E080C16LMPS115.211.78.131,400212475346
XAFD60JXXN1+TXVY81E130D20SMPS115.211.78.131,400212413586
XAHD60JXXN1+TXVY81E120C16LMPS115.211.78.131,000212476169
XAHD60JXXN1+TXVY81E130D20LMPS115.211.78.131,000212475336
XAHD60JBCN1Y81E080C20SMPS115.211.78.131,200212413599
XAHD60JXXN1+TXVY81E080C20LMPS115.211.78.131,200212476173
XAHD60JBCN1Y81E100C16LMPS115.211.78.131,200212475129
XAHD60JBCN1Y81E120C20LMPS115.211.78.131,200212475124
XAHD60JBCN1Y81E130D20SMPS115.211.78.131,000212413585
XAHD60JXXN1+TXVY81E130D20SMPS115.211.78.131,000212413584
XAHD60JBCN1Y82E100C16LMPS115.211.78.131,200212413583
XAHD60JBCN1Y82E120C20LMPS115.211.78.131,200212413579
XAFD60JBCN1Y81E130D20SMPS115.211.78.131,400212413587
XAHD60JBCN1Y81E120C16SMPS115.211.78.131,000212413591
XAHD60JXXN1+TXVY81E120C16SMPS115.211.78.131,000212413590
XAFD60JXXN1+TXVY81E120C16SMPS115.211.78.131,400212413592
XAHD60JBCN1Y81E120C16LMPS115.211.78.131,000212476171
XAHD60JBCN1Y81E080C20LMPS115.211.78.131,200212476175
XAHD60JXXN1+TXVY81E100C20LMPS115.211.78.131,200212475340
XAHD60JBCN1Y81E130D20LMPS115.211.78.131,000212475338
XAHD60JXXN1+TXVY81E120C20SMPS115.211.78.131,200212413588
XAHD60JXXN1+TXVY81E100C20SMPS115.211.78.131,200212413594
XAHD60JXXN1+TXVY81E100C16SMPS115.211.78.131,200212413596
XAHD60JBCN1Y81E100C16SMPS115.211.78.131,200212413597
XAFD60JXXN1+TXVY81E080C16SMPS115.211.78.131,400212413600
XAFD60JBCN1Y81E080C16SMPS115.211.78.131,400212413601
XAFD60JBCN1Y81E130D20LMPS115.211.78.131,400212475806
XAFD60JXXN1+TXVY81E130D20LMPS115.211.78.131,400212475804
XAFD60JBCN1Y81E120C16LMPS115.211.78.131,400212476014
XAFD60JXXN1+TXVY81E120C16LMPS115.211.78.131,400212476012
XAFD60JXXN1+TXVTM9V120D20MP1215.211.78.130,800210341550
XAFD60JXXN1+TXVTP9C120D20MP1315.211.78.130,800210341551
XAFD60JXXN1+TXVYP9C120D20MP1315.211.78.130,800210341552
XAFD60JXXN1+TXVTL8E100C20UH1115.211.78.131,000210341558
XAFC60HXXN1+TXVTL8E100C20UH1115.211.78.131,000210340836
XAHD60JXXN1+JMVT20DC2N1+TXV-15.211.78.129,200210340810
XAFD60HBCN1TM8E130D20MP1115.211.78.131,000210338846
XAHD60HXXN1+JMVT20DC2N1+TXV-15.211.78.129,400210338765
XAFD60HBCN1TMLE130D20MP1115.211.78.131,000210338848
Yearly running cost in 10 large cities$1,617-$4,421

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the York YH2F60TB21?
The York YH2F60TB21 is rated at up to 16.0 SEER2 and 11.7 EER2 for cooling and up to 8.1 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 177 certified matchups SEER2 ranges from 15.2-16.0.
Is the York YH2F60TB21 good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 5-ton model.
How much does the York YH2F60TB21 cost to run per year?
At its rated efficiency it costs about $1,617-$4,421 a year in electricity in large U.S. cities, depending on climate and local rates - for example $2,007 in Phoenix and $3,704 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the York YH2F60TB21?
ENERGY STAR lists 177 certified combinations for this outdoor unit. The highest-rated ones use XAHD60JBCN1, XAFD60JXXN1+JMET18DS2N1+TXV, XAFD60HXXN1+JMVT20DC2N1+TXV.
What refrigerant does the York YH2F60TB21 use?
It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,998/yrYou save $871/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump York YH2F60TB21
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,998
Current system, per year
$2,869
You save per year
$871
Payback
23.5 years
Net after 10 years
-$11,795

Cooling $1,210Heating $788Electricity used: 12,488 kWhSaved vs. a minimum-efficiency heat pump: $207

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 5 ton models

See all 100 5 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of August 12, 2026. How we use the data.