Below average cooling and heating efficiency for a 2.5-ton central heat pump, and certified for cold climates.

Ranks #139 of 199 2.5 ton central heat pumps for cooling efficiency, and costs about $1,120 a year to run in a mixed climate like Atlanta.

SEER2
16.0 Cooling efficiency over a season
Below average · beats 26%
HSPF2
8.1 Heating efficiency over a season
Below average · beats 20%
EER2
11.7 Cooling efficiency on a 95°F day
Average · beats 43%
Heat at 5°F
30,000 BTU/h79% of its 47°F output
Below average · beats 5%

A good fit if…

  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 30,000 BTU/h at 5°F.
  • You want a choice of indoor units - 60 certified pairings.

Think twice if…

  • Cooling cost matters most - its SEER2 is below average for central heat pumps.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.

Calculate my running cost

Details

Specifications2.5 ton, R-454B
General
BrandRunTru
Also sold asAmeristar
Outdoor unit modelA5HL5036A1
SeriesA5HL5
TypeCentral heat pump
Nominal size2.5 ton
CompressorVariable-speed units run longer at low powerTwo-stage
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceJanuary 25, 2025
Last certifiedApril 9, 2025
Cooling
SEER2Seasonal efficiency, higher is better16.0 (range 15.2-16.0)
EER2Efficiency at 95°F outdoors11.0-11.7
Cooling capacity33,000-34,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better8.1
Capacity at 47°F34,000-35,000 BTU/h
Capacity at 17°F30,000-32,000 BTU/h
Capacity at 5°F27,000-30,000 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.75-1.80
ENERGY STAR cold climateYes
Heating output as it gets colder79% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with A5AHV004A1D3 at the standard test temperatures, in BTU/h:

Certified matchups60 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
A5AHV004A1D3 · cold climate-16.011.78.127,000216776157
A5AHV004A1D3 · cold climate-16.011.78.127,000216776161
5TXCB006AS3 · cold climateA952V040BD3SB16.011.08.130,000217194700
5TXCB006AS3 · cold climateA952V040BU3SB16.011.08.130,000217194701
5TXCB006AS3 · cold climateA952V060BD3SB16.011.08.130,000217194702
5TXCB006AS3 · cold climateA952V060BU4SB16.011.08.130,000217194703
5TXCB006AS3 · cold climateA952V080BU4SB16.011.08.130,000217194705
5TXCC007AS3 · cold climateA952V080CU5SB16.011.08.130,000217194706
5TXCC007AS3 · cold climateA952V100CD5SB16.011.78.130,000217194707
5TXCC007AS3 · cold climateA952V100CU5SB16.011.78.130,000217194708
5TXCB006AS3 · cold climateA952V040BD3SB16.011.08.130,000217194709
5TXCB006AS3 · cold climateA952V040BU3SB16.011.08.130,000217194710
5TXCB006AS3 · cold climateA952V060BD3SB16.011.08.130,000217194711
5TXCB006AS3 · cold climateA952V060BU4SB16.011.08.130,000217194712
5TXCB006AS3 · cold climateA952V080BD4SB16.011.08.130,000217194713
5TXCB006AS3 · cold climateA952V080BU4SB16.011.08.130,000217194714
5TXCC007AS3 · cold climateA952V080CU5SB16.011.08.130,000217194715
5TXCC007AS3 · cold climateA952V100CD5SB16.011.78.130,000217194716
5TXCB006AS3 · cold climateA952V080BD4SB16.011.08.130,000217194704
5TXCC007AS3 · cold climateA952V100CU5SB16.011.78.130,000217194717
5TXCB006AS3 · cold climateA801X060BM4SD15.211.08.130,000217194829
5TXCB006AS3 · cold climateA801X080BM4SD15.211.08.130,000217194830
5TXCB006AS3 · cold climateA801X060BM4TD15.211.08.130,000217194831
5TXCB006AS3 · cold climateA801X080BM4TD15.211.08.130,000217194832
5TXCC007AS3 · cold climateA801X080CM5SD15.211.08.130,000217194833
5TXCC007AS3 · cold climateA801X100CM5SD15.211.08.130,000217194834
5TXCC007AS3 · cold climateA801X080CM5TD15.211.08.130,000217194835
5TXCC007AS3 · cold climateA801X100CM5TD15.211.08.130,000217194836
5TXCC007AS3 · cold climateA801X100CM5SD15.211.08.130,000217194854
5TXCC007AS3 · cold climateA801X080CM5TD15.211.08.130,000217194855
5TXCC007AS3 · cold climateA801X100CM5TD15.211.08.130,000217194856
5TXCD008AS3 · cold climateA801X120DM5SD15.211.08.129,000217194857
5TXCD008AS3 · cold climateA801X120DM5TD15.211.08.129,000217194858
5TXCB006AS3 · cold climateA951X060BD3SA15.211.08.130,000217194860
5TXCB006AS3 · cold climateA951X040BU3SA15.211.08.130,000217194859
5TXCC007AS3 · cold climateL9X1C100U5VSA15.211.08.130,000217194828
5TXCC007AS3 · cold climateA951X100CD5SA15.211.08.130,000217194845
5TXCC007AS3 · cold climateA951X100CU5SA15.211.08.130,000217194846
5TXCD008AS3 · cold climateS9X1D120D5PSB15.211.78.129,000217194847
5TXCC007AS3 · cold climateL9X1C100U5VSA15.211.08.130,000217194848
5TXCB006AS3 · cold climateA801X060BM4SD15.211.08.130,000217194849
5TXCB006AS3 · cold climateA801X080BM4SD15.211.08.130,000217194850
5TXCB006AS3 · cold climateA801X060BM4TD15.211.08.130,000217194851
5TXCB006AS3 · cold climateA801X080BM4TD15.211.08.130,000217194852
5TXCD008AS3 · cold climateA801X120DM5SD15.211.08.129,000217194837
5TXCD008AS3 · cold climateA801X120DM5TD15.211.08.129,000217194838
5TXCB006AS3 · cold climateA951X040BU3SA15.211.08.130,000217194839
5TXCB006AS3 · cold climateA951X060BU4SA15.211.08.130,000217194841
5TXCB006AS3 · cold climateA951X080BD4SA15.211.08.130,000217194842
5TXCB006AS3 · cold climateA951X080BU4SA15.211.08.130,000217194843
5TXCC007AS3 · cold climateA951X080CU5SA15.211.08.130,000217194844
5TXCB006AS3 · cold climateA951X060BU4SA15.211.08.130,000217194861
5TXCB006AS3 · cold climateA951X080BU4SA15.211.08.130,000217194863
5TXCC007AS3 · cold climateA951X080CU5SA15.211.08.130,000217194864
5TXCC007AS3 · cold climateA951X100CU5SA15.211.08.130,000217194866
5TXCD008AS3 · cold climateS9X1D120D5PSB15.211.78.129,000217194867
5TXCC007AS3 · cold climateA951X100CD5SA15.211.08.130,000217194865
5TXCC007AS3 · cold climateA801X080CM5SD15.211.08.130,000217194853
5TXCB006AS3 · cold climateA951X060BD3SA15.211.08.130,000217194840
5TXCB006AS3 · cold climateA951X080BD4SA15.211.08.130,000217194862
Yearly running cost in 10 large cities$971-$2,703

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the RunTru A5HL5036A1?
The RunTru A5HL5036A1 is rated at up to 16.0 SEER2 and 11.7 EER2 for cooling and up to 8.1 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 60 certified matchups SEER2 ranges from 15.2-16.0.
Is the RunTru A5HL5036A1 good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 30,000 BTU/h at 5°F with a COP of 1.80, so it is still 1.8 times as efficient as electric resistance heat at that temperature.
How much does the RunTru A5HL5036A1 cost to run per year?
At its rated efficiency it costs about $971-$2,703 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,212 in Phoenix and $2,270 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the RunTru A5HL5036A1?
ENERGY STAR lists 60 certified combinations for this outdoor unit. The highest-rated ones use A5AHV004A1D3, 5TXCB006AS3, 5TXCC007AS3.
What refrigerant does the RunTru A5HL5036A1 use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,210/yrYou save $524/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump RunTru A5HL5036A1
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,210
Current system, per year
$1,734
You save per year
$524
Payback
23.8 years
Net after 10 years
-$7,257

Cooling $726Heating $484Electricity used: 7,562 kWhSaved vs. a minimum-efficiency heat pump: $125

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 2.5 ton models

See all 199 2.5 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of April 9, 2025. How we use the data.