HVAC Rated

3-ton central heat pump · VANTIX

Sure SP15AY36AJ2N

Below average cooling and heating efficiency for a 3-ton central heat pump, but not rated for cold climates.

Ranks #259 of 302 3 ton central heat pumps for cooling efficiency, and costs about $1,146 a year to run in a mixed climate like Atlanta.

SEER2
16.0 Cooling efficiency over a season
Below average · beats 26%
HSPF2
7.8 Heating efficiency over a season
Below average · beats 5%
EER2
11.7 Cooling efficiency on a 95°F day
Average · beats 43%
Heat at 5°F
18,900 BTU/h54% of its 47°F output
Average · beats 58%

A good fit if…

  • You want a choice of indoor units - 143 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • Cooling cost matters most - its SEER2 is below average for central heat pumps.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.

Calculate my running cost

Details

Specifications3 ton, R-454B
General
BrandSure
Also sold asRUSSELL
Outdoor unit modelSP15AY36AJ2N
SeriesVANTIX
TypeCentral heat pump
Nominal size3 ton
CompressorVariable-speed units run longer at low powerTwo-stage
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceAugust 13, 2024
Last certifiedJanuary 31, 2025
Cooling
SEER2Seasonal efficiency, higher is better16.0 (range 15.2-16.0)
EER2Efficiency at 95°F outdoors11.7-12.0
Cooling capacity34,200 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8
Capacity at 47°F33,200-34,200 BTU/h
Capacity at 17°F23,400-33,200 BTU/h
Capacity at 5°F17,300-18,900 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.00-2.10
ENERGY STAR cold climateNo
Heating output as it gets colder54% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with TCFY3617STANM at the standard test temperatures, in BTU/h:

Certified matchups143 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 143 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
TCFY3617STANMS801V1004A17UH16.011.77.818,400215656656
TCFY3617STANMS801V1004A17UH16.011.77.818,400215656659
TCFY3617STANMS802V1004A17UH16.011.77.818,400215656750
TCFY3617STANMS802V1004A17UH16.011.77.818,400215656752
SH2VY3621STACN-16.012.07.817,800216030764
SH2VY3617STACN-16.012.07.817,900216030765
SH2VY3621STACN-16.012.07.817,800216030766
SH2VY3617STACN-16.012.07.817,900216030767
TCFY3621STANMS801V1005A21UHU16.011.77.818,400216545279
TCFY3621STANMS801V1004A17UH16.011.77.818,400216545283
TCFY3621STANMS801V0755A21UH16.011.77.818,400216545286
TCFY3621STANMS801V0755A21DZ16.011.77.818,300216545281
TCFY3621STANMS801V1005A21DZ16.011.77.818,200216545291
TCFY3621STANMS801V1005A21UHN16.011.77.818,300216545293
TCFY3621STANMS801V1005A21UHS16.011.77.818,300216545304
RF2TY3624STANS-16.011.77.818,100216533499
SB2CY3621STANM-16.011.77.818,000216533520
TCFY3621STANMS801V0755A21DZ16.011.77.818,300216545030
TCFY3621STANMS801V1004A17UH16.011.77.818,400216545033
TCFY3621STANMS801V0755A21UH16.011.77.818,400216545035
TCFY3621STANMS801V1005A21UHN16.011.77.818,300216545042
TCFY3621STANMS801V1005A21DZ16.011.77.818,200216545040
TCFY3621STANMS801V1005A21UHS16.011.77.818,300216545173
TCFY3621STANMS951V0705A21UHU16.011.77.818,500216545180
TCFY3621STANMS802V1004A17UH16.011.77.818,400216546373
TCFY3621STANMS802V0755A21DZ16.011.77.818,300216546390
TCFY3621STANMS802V0755A21UH16.011.77.818,400216546395
TCFY3621STANMS802V1005A21DZ16.011.77.818,200216546400
TCFY3621STANMS802V1005A21UH16.011.77.818,300216546402
SB2CY3621STANM-16.011.77.818,000216533523
RF2TY3624STANS-16.011.77.818,100216533502
TCFY3621STANMS802V1004A17UH16.011.77.818,400216546421
TCFY3621STANMS802V0755A21DZ16.011.77.818,300216546423
TCFY3621STANMS802V0755A21UH16.011.77.818,400216546428
TCFY3621STANMS802V1005A21DZ16.011.77.818,200216546447
TCFY3621STANMS802V1005A21UH16.011.77.818,300216546449
TCFY3621STANMS951V0705A21UHU16.011.77.818,500216545383
TCFY3621STANMS801V1005A21UHU16.011.77.818,400216545449
SH2CY3617STANN-15.211.77.817,300215415462
SH2CY3617STANN-15.211.77.817,300215415475
TCFY3617STANMS801V0503A14UH15.211.77.818,600215656613
TCFY3617STANMS801V0754A17UH15.211.77.818,300215656630
TCFY3617STANMS801V0754A17DZ15.211.77.818,600215656632
TCFY3617STANMS801V0754A17DZ15.211.77.818,600215656633
TCFY3617STANMS801V0503A14UH15.211.77.818,600215656636
TCFY3617STANMS801V0504A17UHN15.211.77.818,900215656697
TCFY3617STANMS801V0504A17UHN15.211.77.818,900215656699
TCFY3617STANMS801V0503A14DZ15.211.77.818,400215656706
TCFY3617STANMS801V0503A14DZ15.211.77.818,400215656710
TCFY3617STANMS801V0754A17UH15.211.77.818,300215656712
TCFY3617STANMS801V0704A17UH15.211.77.818,700215656729
TCFY3617STANMS801V0704A17UH15.211.77.818,700215656731
TCFY3617STANMS802V0754A17DZ15.211.77.818,600215656747
TCFY3617STANMS802V0503A14DZ15.211.77.818,400215656753
TCFY3617STANMS802V0754A17DZ15.211.77.818,600215656762
TCFY3617STANMS802V0503A14DZ15.211.77.818,400215656777
TCFY3617STANMS802V0754A17UH15.211.77.818,300215656781
TCFY3617STANMS802V0754A17UH15.211.77.818,300215656782
TCFY3617STANMS801V0504A17UHS15.211.77.818,900215656668
TCFY3617STANMS801V0504A17UHS15.211.77.818,900215656669
Yearly running cost in 10 large cities$1,005-$2,754

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Sure SP15AY36AJ2N?
The Sure SP15AY36AJ2N is rated at up to 16.0 SEER2 and 11.7 EER2 for cooling and up to 7.8 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 143 certified matchups SEER2 ranges from 15.2-16.0.
Is the Sure SP15AY36AJ2N good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 3-ton model.
How much does the Sure SP15AY36AJ2N cost to run per year?
At its rated efficiency it costs about $1,005-$2,754 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,248 in Phoenix and $2,307 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Sure SP15AY36AJ2N?
ENERGY STAR lists 143 certified combinations for this outdoor unit. The highest-rated ones use TCFY3617STANM, SH2VY3621STACN, SH2VY3617STACN.
What refrigerant does the Sure SP15AY36AJ2N use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,243/yrYou save $520/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Sure SP15AY36AJ2N
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,243
Current system, per year
$1,763
You save per year
$520
Payback
25.0 years
Net after 10 years
-$7,800

Cooling $752Heating $491Electricity used: 7,772 kWhSaved vs. a minimum-efficiency heat pump: $109

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 3 ton models

See all 302 3 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of January 31, 2025. How we use the data.