HVAC Rated

3-ton central heat pump · F-SERIES

Friedrich FRP15AY36AJ2N

Below average cooling and heating efficiency for a 3-ton central heat pump, but not rated for cold climates.

Ranks #255 of 302 3 ton central heat pumps for cooling efficiency, and costs about $1,146 a year to run in a mixed climate like Atlanta.

SEER2
16.0 Cooling efficiency over a season
Below average · beats 26%
HSPF2
7.8 Heating efficiency over a season
Below average · beats 5%
EER2
11.7 Cooling efficiency on a 95°F day
Average · beats 43%
Heat at 5°F
18,900 BTU/h54% of its 47°F output
Average · beats 58%

A good fit if…

  • You want a choice of indoor units - 138 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • Cooling cost matters most - its SEER2 is below average for central heat pumps.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.

Calculate my running cost

Details

Specifications3 ton, R-454B
General
BrandFriedrich
Outdoor unit modelFRP15AY36AJ2N
SeriesF-SERIES
TypeCentral heat pump
Nominal size3 ton
CompressorVariable-speed units run longer at low powerTwo-stage
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceAugust 13, 2024
Last certifiedJanuary 31, 2025
Cooling
SEER2Seasonal efficiency, higher is better16.0 (range 15.2-16.0)
EER2Efficiency at 95°F outdoors11.7-12.0
Cooling capacity34,200 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8
Capacity at 47°F33,200-34,200 BTU/h
Capacity at 17°F23,400-33,200 BTU/h
Capacity at 5°F17,300-18,900 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.00-2.10
ENERGY STAR cold climateNo
Heating output as it gets colder54% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with TCFY3617STANM at the standard test temperatures, in BTU/h:

Certified matchups138 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 138 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
TCFY3617STANMFR801V1004A17UH16.011.77.818,400215656640
TCFY3617STANMFR802V1004A17UH16.011.77.818,400215656794
FRH2VY3621STACN-16.012.07.817,800216030718
FRH2VY3617STACN-16.012.07.817,900216030719
RCFY3621STANMFR951V0705A21UHU16.011.77.818,500216545729
RCFY3621STANMFR801V1005A21UHU16.011.77.818,400216545796
FRB2TY3621STANM-16.011.77.818,000216533363
RF2TY3624STANS-16.011.77.818,100216533489
RCFY3617STANMFR801V1004A17UH16.011.77.818,400216544304
RCFY3617STANMFR802V1004A17UH16.011.77.818,400216544708
RCFY3621STANMFR801V1004A17UH16.011.77.818,400216545629
TCFY3621STANMFR801V1005A21UHU16.011.77.818,400216545624
RCFY3621STANMFR801V0755A21DZ16.011.77.818,300216545627
RCFY3621STANMFR801V0755A21UH16.011.77.818,400216545631
RCFY3621STANMFR801V1005A21DZ16.011.77.818,200216545636
RCFY3621STANMFR801V1005A21UHN16.011.77.818,300216545638
RCFY3621STANMFR801V1005A21UHS16.011.77.818,300216545650
TCFY3621STANMFR802V1004A17UH16.011.77.818,400216546454
TCFY3621STANMFR802V0755A21DZ16.011.77.818,300216546456
TCFY3621STANMFR802V0755A21UH16.011.77.818,400216546461
TCFY3621STANMFR802V1005A21DZ16.011.77.818,200216546485
TCFY3621STANMFR802V1005A21UH16.011.77.818,300216546487
RCFY3621STANMFR802V1004A17UH16.011.77.818,400216546492
RCFY3621STANMFR802V0755A21DZ16.011.77.818,300216546495
RCFY3621STANMFR802V0755A21UH16.011.77.818,400216546500
RCFY3621STANMFR802V1005A21DZ16.011.77.818,200216546523
RCFY3621STANMFR802V1005A21UH16.011.77.818,300216546526
TCFY3621STANMFR801V0755A21UH16.011.77.818,400216545456
TCFY3621STANMFR801V0755A21DZ16.011.77.818,300216545451
TCFY3621STANMFR801V1004A17UH16.011.77.818,400216545454
TCFY3621STANMFR801V1005A21DZ16.011.77.818,200216545461
TCFY3621STANMFR801V1005A21UHN16.011.77.818,300216545463
TCFY3621STANMFR801V1005A21UHS16.011.77.818,300216545475
TCFY3621STANMFR951V0705A21UHU16.011.77.818,500216545557
FRH2TY3617STANN-15.211.77.817,300215415472
TCFY3617STANMFR801V0504A17UHN15.211.77.818,900215656608
TCFY3617STANMFR801V0704A17UH15.211.77.818,700215656609
TCFY3617STANMFR801V0504A17UHS15.211.77.818,900215656634
TCFY3617STANMFR801V0754A17UH15.211.77.818,300215656658
TCFY3617STANMFR801V0754A17DZ15.211.77.818,600215656679
TCFY3617STANMFR801V0503A14UH15.211.77.818,600215656682
TCFY3617STANMFR802V0754A17DZ15.211.77.818,600215656742
TCFY3617STANMFR802V0503A14UH15.211.77.818,600215656766
TCFY3617STANMFR801V0503A14DZ15.211.77.818,400215656671
TCFY3617STANMFR802V0503A14DZ15.211.77.818,400215656793
TCFY3617STANMFR802V0754A17UH15.211.77.818,300215656798
TCFY3617STANMFR951V0603A17M415.211.77.818,600215656874
TCFY3617STANMFR921V0703A17M415.211.77.818,400215656881
TCFY3617STANMFR951V0703A17M415.211.77.818,400215656895
TCFY3617STANMFR951V0403A17M415.211.77.818,600215656897
TCFY3617STANMFR921V0603A17M415.211.77.818,600215656954
TCFY3617STANMFR921V0403A17M415.211.77.818,600215656934
TCFY3617STANMFR962V0403A17M415.211.77.818,600215657091
TCFY3617STANMFR962V0603A17M415.211.77.818,600215657149
TCFY3617STANMFR962V0703A17M415.211.77.818,400215657239
TCFY3617STANMFR802V0504A17UH15.211.77.818,900215657427
TCFY3617STANMFR801V0504A17UHU15.211.77.818,700215657510
TCFY3621STANMFR962V0603A17M415.211.77.818,600216546242
TCFY3621STANMFR962V1005A21M415.211.77.818,500216546244
TCFY3621STANMFR962V0403A17M415.211.77.818,600216546247
Yearly running cost in 10 large cities$1,005-$2,754

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Friedrich FRP15AY36AJ2N?
The Friedrich FRP15AY36AJ2N is rated at up to 16.0 SEER2 and 11.7 EER2 for cooling and up to 7.8 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 138 certified matchups SEER2 ranges from 15.2-16.0.
Is the Friedrich FRP15AY36AJ2N good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 3-ton model.
How much does the Friedrich FRP15AY36AJ2N cost to run per year?
At its rated efficiency it costs about $1,005-$2,754 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,248 in Phoenix and $2,307 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Friedrich FRP15AY36AJ2N?
ENERGY STAR lists 138 certified combinations for this outdoor unit. The highest-rated ones use TCFY3617STANM, FRH2VY3621STACN, FRH2VY3617STACN.
What refrigerant does the Friedrich FRP15AY36AJ2N use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,243/yrYou save $520/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Friedrich FRP15AY36AJ2N
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,243
Current system, per year
$1,763
You save per year
$520
Payback
25.0 years
Net after 10 years
-$7,800

Cooling $752Heating $491Electricity used: 7,772 kWhSaved vs. a minimum-efficiency heat pump: $109

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 3 ton models

See all 302 3 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of January 31, 2025. How we use the data.