3-ton central heat pump · 15 SEER2 HP
WeatherMaker PH5SAN536**AB
Below average cooling and heating efficiency for a 3-ton central heat pump, but not rated for cold climates.
Ranks #251 of 302 3 ton central heat pumps for cooling efficiency, and costs about $1,131 a year to run in a mixed climate like Atlanta.
- SEER2
- 16.0 Cooling efficiency over a seasonBelow average · beats 26%
- HSPF2
- 8.0 Heating efficiency over a seasonBelow average · beats 12%
- EER2
- 13.0 Cooling efficiency on a 95°F dayVery good · beats 89%
- Heat at 5°F
- 18,100 BTU/h48% of its 47°F outputVery good · beats 80%
A good fit if…
- You want a choice of indoor units - 21 certified pairings.
Think twice if…
- You often see nights below 0°F - it is not cold-climate certified.
- Cooling cost matters most - its SEER2 is below average for central heat pumps.
- You mainly need heat - its HSPF2 is below average for central heat pumps.
- Comfort and noise matter - a single-stage compressor runs only full-on or off.
Details
Specifications
| General | |
|---|---|
| Brand | WeatherMaker |
| Outdoor unit model | PH5SAN536**AB |
| Series | 15 SEER2 HP |
| Type | Central heat pump |
| Nominal size | 3 ton |
| CompressorVariable-speed units run longer at low power | Single stage |
| Refrigerant | R-454B |
| Connected (smart) capable | No |
| On the market since | January 1, 2024 |
| Last certified | September 22, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 16.0 (range 15.2-16.0) |
| EER2Efficiency at 95°F outdoors | 12.0-13.0 |
| Cooling capacity | 33,800-36,800 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 7.8-8.0 |
| Capacity at 47°F | 33,200-36,400 BTU/h |
| Capacity at 17°F | 21,000-22,800 BTU/h |
| Capacity at 5°F | 16,100-18,100 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 2.00-2.22 |
| ENERGY STAR cold climate | No |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with FEVA0048**+NAVA54801CK at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit and furnace. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | Furnace | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|---|
| FEVA0048**+NAVA54801CK | - | 16.0 | 13.0 | 8.0 | 17,400 | 218754062 |
| FJ5AN*C48L | - | 15.5 | 13.0 | 7.8 | 17,400 | 218754746 |
| FMA5X36**AL | - | 15.5 | 12.5 | 7.8 | 17,000 | 218754048 |
| FEVB0048**+NAVA54801CK | - | 15.5 | 12.5 | 7.8 | 17,400 | 218754040 |
| PF5MN*C48L | - | 15.5 | 13.0 | 7.8 | 17,400 | 218753942 |
| PF5TNXC48L | - | 15.5 | 12.5 | 7.8 | 16,700 | 218753938 |
| FM(C,U)5S36**AL | - | 15.2 | 12.0 | 8.0 | 17,300 | 218754756 |
| FJ5AN*C42L | - | 15.2 | 12.5 | 7.8 | 16,100 | 218754744 |
| FM(C,U)5Z36**AL | - | 15.2 | 12.5 | 7.8 | 17,200 | 218754057 |
| PF5MN*C42L | - | 15.2 | 12.5 | 7.8 | 16,100 | 218753937 |
| CVAVA4224XMA | PG80MSUA60100C** | 15.2 | 12.0 | 7.8 | 18,100 | 218753930 |
| CAA**4821AM | PG92MSAA60100C** | 15.2 | 12.0 | 7.8 | 17,600 | 218753929 |
| CAA**4821AM | PG80VTLB60090C** | 15.2 | 12.0 | 7.8 | 17,500 | 218753928 |
| CAA**4821AM | PG80MSUA60080C** | 15.2 | 12.0 | 7.8 | 17,300 | 218753927 |
| CAA**4821AM | PG80MSUA48060B** | 15.2 | 12.0 | 7.8 | 17,600 | 218753926 |
| CAA**4821AM | PG80MS(A,L)A60110C** | 15.2 | 12.0 | 7.8 | 17,600 | 218753925 |
| CAA**4821AM | PG80MS(A,L)A60090C** | 15.2 | 12.0 | 7.8 | 17,500 | 218753924 |
| CAA**4321AM | PG92MSAA60100C** | 15.2 | 12.0 | 7.8 | 17,900 | 218753923 |
| CAA**4321AM | PG80MS(A,L)A60110C** | 15.2 | 12.0 | 7.8 | 18,000 | 218753922 |
| CAA**4321AM | PG80MS(A,L)A60090C** | 15.2 | 12.0 | 7.8 | 17,900 | 218753921 |
| CAA**3721AM | PG80MS(A,L)A60090C** | 15.2 | 12.0 | 7.8 | 17,900 | 218753920 |
Yearly running cost in 10 large cities
- Phoenix, AZ$1,254/yr
- Miami, FL$1,021/yr
- Houston, TX$1,124/yr
- Atlanta, GA$1,131/yr
- Los Angeles, CA$1,099/yr
- New York, NY$2,694/yr
- Chicago, IL$2,186/yr
- Denver, CO$1,816/yr
- Seattle, WA$1,115/yr
- Minneapolis, MN$2,247/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the WeatherMaker PH5SAN536**AB?
- The WeatherMaker PH5SAN536**AB is rated at up to 16.0 SEER2 and 13.0 EER2 for cooling and up to 8.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 21 certified matchups SEER2 ranges from 15.2-16.0.
- Is the WeatherMaker PH5SAN536**AB good for cold climates?
- It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 3-ton model.
- How much does the WeatherMaker PH5SAN536**AB cost to run per year?
- At its rated efficiency it costs about $1,021-$2,694 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,254 in Phoenix and $2,247 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the WeatherMaker PH5SAN536**AB?
- ENERGY STAR lists 21 certified combinations for this outdoor unit. The highest-rated ones use FEVA0048**+NAVA54801CK, FJ5AN*C48L, FMA5X36**AL.
- What refrigerant does the WeatherMaker PH5SAN536**AB use?
- It uses R-454B.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 3 ton models
- NORDYNE SH4BF5M2SX36K16.0 SEER2 · 8.0 HSPF2
- AC Pro BH714S36P-**A16.0 SEER2 · 7.8 HSPF2
- Maytag PSH4BF5M2SX36K16.0 SEER2 · 8.0 HSPF2
- Comfort-Aire HSA1436S1-**A16.0 SEER2 · 7.8 HSPF2
- Lennox EL16KP1-036-230A16.0 SEER2 · 8.0 HSPF2
- DuraSTAR DRHP15B36AJ2AN16.0 SEER2 · 7.8 HSPF2
- Heil R5H5S36*K*AAA16.0 SEER2 · 8.0 HSPF2
- Friedrich FRP15AY36AJ2N16.0 SEER2 · 7.8 HSPF2
See all 302 3 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of September 22, 2026. How we use the data.