3-ton central heat pump · HSA14 Series
Comfort-Aire HSA1436S1-**A
Below average cooling and heating efficiency for a 3-ton central heat pump, but not rated for cold climates.
Ranks #253 of 302 3 ton central heat pumps for cooling efficiency, and costs about $1,180 a year to run in a mixed climate like Atlanta.
- SEER2
- 16.0 Cooling efficiency over a seasonBelow average · beats 26%
- HSPF2
- 7.8 Heating efficiency over a seasonBelow average · beats 5%
- EER2
- 13.4 Cooling efficiency on a 95°F dayExcellent · beats 94%
- Heat at 5°F
- 16,800 BTU/h48% of its 47°F outputBelow average · beats 39%
A good fit if…
- You want a choice of indoor units - 32 certified pairings.
Think twice if…
- You often see nights below 0°F - it is not cold-climate certified.
- Cooling cost matters most - its SEER2 is below average for central heat pumps.
- You mainly need heat - its HSPF2 is below average for central heat pumps.
- Comfort and noise matter - a single-stage compressor runs only full-on or off.
Details
Specifications
| General | |
|---|---|
| Brand | Comfort-Aire |
| Also sold as | Century |
| Outdoor unit model | HSA1436S1-**A |
| Series | HSA14 Series |
| Type | Central heat pump |
| Nominal size | 3 ton |
| CompressorVariable-speed units run longer at low power | Single stage |
| Refrigerant | R-454B |
| Connected (smart) capable | No |
| On the market since | October 1, 2024 |
| Last certified | June 29, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 16.0 (range 15.2-16.0) |
| EER2Efficiency at 95°F outdoors | 12.5-13.4 |
| Cooling capacity | 36,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 7.8 |
| Capacity at 47°F | 31,400-35,000 BTU/h |
| Capacity at 17°F | 20,000-21,200 BTU/h |
| Capacity at 5°F | 15,700-16,800 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.90-2.00 |
| ENERGY STAR cold climate | No |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with 7EH42CX-**+TDR at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit and furnace. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | Furnace | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|---|
| 7EH42CX-**+TDR | GUH80C090C5MP* | 16.0 | 13.4 | 7.8 | 16,600 | 216372716 |
| 7EH42CX-**+TDR | GUH80C090C5MP* | 16.0 | 13.4 | 7.8 | 16,600 | 216372610 |
| 7E[C,U]48CX-**+TDR | GUH80C090C5MP* | 15.5 | 13.2 | 7.8 | 16,600 | 216372711 |
| 7E[C,U]48CX-**+TDR | GUH80C110C5MP* | 15.5 | 13.4 | 7.8 | 16,600 | 216372712 |
| 7E[C,U]48CX-**+TDR | GUH92C110C4MP* | 15.5 | 13.2 | 7.8 | 16,600 | 216372713 |
| 7EH42BX-**+TDR | GUH80C070B3MP* | 15.5 | 13.0 | 7.8 | 16,600 | 216372714 |
| 7EH42CX-**+TDR | GUH80C110C5MP* | 15.5 | 13.2 | 7.8 | 16,600 | 216372611 |
| 7EH42CX-**+TDR | GUH92C110C4MP* | 15.5 | 13.2 | 7.8 | 16,400 | 216372613 |
| 7EH42CX-**+TDR | GUH92C110C5MP* | 15.5 | 13.0 | 7.8 | 16,800 | 216372614 |
| 7EH42CX-**+TDR | GUH96C090C4MP* | 15.5 | 13.0 | 7.8 | 16,700 | 216372615 |
| 7EH42CX-**+TDR | GUH92C090C4MP* | 15.5 | 13.0 | 7.8 | 16,700 | 216372612 |
| 7EH42BX-**+TDR | GUH80C090B4MP* | 15.5 | 13.2 | 7.8 | 16,600 | 216372715 |
| 7EH42CX-**+TDR | GUH80C110C5MP* | 15.5 | 13.2 | 7.8 | 16,600 | 216372717 |
| 7EH42CX-**+TDR | GUH92C090C4MP* | 15.5 | 13.0 | 7.8 | 16,700 | 216372718 |
| 7EH42CX-**+TDR | GUH92C110C4MP* | 15.5 | 13.2 | 7.8 | 16,400 | 216372719 |
| 7EH42CX-**+TDR | GUH92C110C5MP* | 15.5 | 13.0 | 7.8 | 16,800 | 216372720 |
| 7EH42CX-**+TDR | GUH96C090C4MP* | 15.5 | 13.0 | 7.8 | 16,700 | 216372721 |
| 7E[C,U]48CX-**+TDR | GUH80C090C5MP* | 15.5 | 13.2 | 7.8 | 16,600 | 216372605 |
| 7E[C,U]48CX-**+TDR | GUH80C110C5MP* | 15.5 | 13.4 | 7.8 | 16,600 | 216372606 |
| 7E[C,U]48CX-**+TDR | GUH92C110C4MP* | 15.5 | 13.2 | 7.8 | 16,600 | 216372607 |
| 7EH42BX-**+TDR | GUH80C070B3MP* | 15.5 | 13.0 | 7.8 | 16,600 | 216372608 |
| 7EH42BX-**+TDR | GUH80C090B4MP* | 15.5 | 13.2 | 7.8 | 16,600 | 216372609 |
| 7EH42CX-**+TDR | GUH97T110C5MP* | 15.5 | 13.2 | 7.8 | 16,500 | 216498795 |
| 7EH42CX-**+TDR | GUH97T110C5MP* | 15.5 | 13.2 | 7.8 | 16,500 | 216498826 |
| HMA36VX1*- | - | 15.2 | 13.0 | 7.8 | 15,700 | 216372709 |
| HMA36VX1*- | - | 15.2 | 13.0 | 7.8 | 15,700 | 216372603 |
| 7E[C,U]48CX-**+TDR | GUH80X100C5MP* | 15.2 | 13.0 | 7.8 | 16,800 | 216372604 |
| 7E[C,U]48CX-**+TDR | GUH80X100C5MP* | 15.2 | 13.0 | 7.8 | 16,800 | 216372710 |
| HMA36CX1*- | - | 15.2 | 13.0 | 7.8 | 15,900 | 217662731 |
| HMA36CX1*- | - | 15.2 | 13.0 | 7.8 | 15,900 | 217662737 |
| HMAS42CX1S- | - | 15.2 | 12.5 | 7.8 | 16,500 | 218499738 |
| HMAS42CX1S- | - | 15.2 | 12.5 | 7.8 | 16,500 | 218499736 |
Yearly running cost in 10 large cities
- Phoenix, AZ$1,302/yr
- Miami, FL$1,057/yr
- Houston, TX$1,167/yr
- Atlanta, GA$1,180/yr
- Los Angeles, CA$1,148/yr
- New York, NY$2,820/yr
- Chicago, IL$2,289/yr
- Denver, CO$1,903/yr
- Seattle, WA$1,169/yr
- Minneapolis, MN$2,355/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the Comfort-Aire HSA1436S1-**A?
- The Comfort-Aire HSA1436S1-**A is rated at up to 16.0 SEER2 and 13.4 EER2 for cooling and up to 7.8 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 32 certified matchups SEER2 ranges from 15.2-16.0.
- Is the Comfort-Aire HSA1436S1-**A good for cold climates?
- It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 3-ton model.
- How much does the Comfort-Aire HSA1436S1-**A cost to run per year?
- At its rated efficiency it costs about $1,057-$2,820 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,302 in Phoenix and $2,355 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the Comfort-Aire HSA1436S1-**A?
- ENERGY STAR lists 32 certified combinations for this outdoor unit. The highest-rated ones use 7EH42CX-**+TDR, 7E[C,U]48CX-**+TDR, 7EH42BX-**+TDR.
- What refrigerant does the Comfort-Aire HSA1436S1-**A use?
- It uses R-454B.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 3 ton models
- AC Pro BH714S36P-**A16.0 SEER2 · 7.8 HSPF2
- DuraSTAR DRHP15B36AJ2AN16.0 SEER2 · 7.8 HSPF2
- WeatherMaker PH5SAN536**AB16.0 SEER2 · 8.0 HSPF2
- Friedrich FRP15AY36AJ2N16.0 SEER2 · 7.8 HSPF2
- NORDYNE SH4BF5M2SX36K16.0 SEER2 · 8.0 HSPF2
- Friedrich FWP15AY36AJ2N16.0 SEER2 · 7.8 HSPF2
- Maytag PSH4BF5M2SX36K16.0 SEER2 · 8.0 HSPF2
- GE NS16H36SA5-**A16.0 SEER2 · 7.8 HSPF2
See all 302 3 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of June 29, 2026. How we use the data.