3-ton central heat pump · 7HP14F Seies
Ducane 7HP14F36P-**A
Below average cooling and heating efficiency for a 3-ton central heat pump, but not rated for cold climates.
Ranks #244 of 302 3 ton central heat pumps for cooling efficiency, and costs about $1,162 a year to run in a mixed climate like Atlanta.
- SEER2
- 16.0 Cooling efficiency over a seasonBelow average · beats 26%
- HSPF2
- 8.0 Heating efficiency over a seasonBelow average · beats 12%
- EER2
- 13.4 Cooling efficiency on a 95°F dayExcellent · beats 94%
- Heat at 5°F
- 16,800 BTU/h48% of its 47°F outputAverage · beats 51%
A good fit if…
- You want a choice of indoor units - 135 certified pairings.
Think twice if…
- You often see nights below 0°F - it is not cold-climate certified.
- Cooling cost matters most - its SEER2 is below average for central heat pumps.
- You mainly need heat - its HSPF2 is below average for central heat pumps.
- Comfort and noise matter - a single-stage compressor runs only full-on or off.
Details
Specifications
| General | |
|---|---|
| Brand | Ducane |
| Also sold as | ALLIED, Concord, Breeze33 |
| Outdoor unit model | 7HP14F36P-**A |
| Series | 7HP14F Seies |
| Type | Central heat pump |
| Nominal size | 3 ton |
| CompressorVariable-speed units run longer at low power | Single stage |
| Refrigerant | R-454B |
| Connected (smart) capable | No |
| On the market since | October 1, 2024 |
| Last certified | June 29, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 16.0 (range 15.2-16.0) |
| EER2Efficiency at 95°F outdoors | 12.5-13.4 |
| Cooling capacity | 35,400-36,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 7.8-8.0 |
| Capacity at 47°F | 31,400-35,600 BTU/h |
| Capacity at 17°F | 20,000-21,200 BTU/h |
| Capacity at 5°F | 15,700-16,800 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.90-2.06 |
| ENERGY STAR cold climate | No |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with 7E[C,U]48CX-**+TDR at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 135 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | Furnace | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|---|
| 7E[C,U]48CX-**+TDR | 80G2UH110CE20* | 16.0 | 13.4 | 7.8 | 16,500 | 215736008 |
| 7E[C,U]48CX-**+TDR | 80G2UH110CE20L* | 16.0 | 13.4 | 7.8 | 16,500 | 215736009 |
| 7E[C,U]48CX-**+TDR | 80G2UH110CE20L* | 16.0 | 13.4 | 7.8 | 16,500 | 215736083 |
| 7EH42CX-**+TDR | 80G2UH110CE16* | 16.0 | 13.2 | 7.8 | 16,400 | 215735963 |
| 7EH42CX-**+TDR | 80G2UH110CE20* | 16.0 | 13.4 | 7.8 | 16,500 | 215735964 |
| 7EH42CX-**+TDR | 80G2UH110CE20L* | 16.0 | 13.4 | 7.8 | 16,500 | 215735965 |
| 7EH42CX-**+TDR | 80G1UH090CE20* | 16.0 | 13.4 | 7.8 | 16,600 | 215735968 |
| 7E[C,U]48CX-**+TDR | 80G2UH110CE20* | 16.0 | 13.4 | 7.8 | 16,500 | 215736082 |
| 7EH42CX-**+TDR | 80G2UH110CE16* | 16.0 | 13.2 | 7.8 | 16,400 | 215736111 |
| 7EH42CX-**+TDR | 80G2UH110CE20* | 16.0 | 13.4 | 7.8 | 16,500 | 215736112 |
| 7EH42CX-**+TDR | 80G1UH090CE20* | 16.0 | 13.4 | 7.8 | 16,600 | 215736116 |
| 7E[C,U]48CX-**+TDR | 80G2UH110CE20* | 16.0 | 13.4 | 7.8 | 16,500 | 215735934 |
| 7E[C,U]48CX-**+TDR | 80G2UH110CE20L* | 16.0 | 13.4 | 7.8 | 16,500 | 215735935 |
| 7EH42CX-**+TDR | 80G2UH110CE20* | 16.0 | 13.4 | 7.8 | 16,500 | 215736038 |
| 7EH42CX-**+TDR | 80G1UH090CE20* | 16.0 | 13.4 | 7.8 | 16,600 | 215736042 |
| 7EH42CX-**+TDR | 80G2UH110CE20L* | 16.0 | 13.4 | 7.8 | 16,500 | 215736039 |
| 7EH42CX-**+TDR | 80G2UH110CE20L* | 16.0 | 13.4 | 7.8 | 16,500 | 215736113 |
| 7EH42CX-**+TDR | 80G2UH110CE16* | 16.0 | 13.2 | 7.8 | 16,400 | 215736037 |
| 7E[C,U]48CX-**+TDR | 80G2UH110CE20* | 16.0 | 13.4 | 7.8 | 16,500 | 215792647 |
| 7E[C,U]48CX-**+TDR | 80G2UH110CE20L* | 16.0 | 13.4 | 7.8 | 16,500 | 215792648 |
| 7EH42CX-**+TDR | 80G1UH090CE20* | 16.0 | 13.4 | 7.8 | 16,600 | 215792681 |
| 7EH42CX-**+TDR | 80G2UH110CE16* | 16.0 | 13.2 | 7.8 | 16,400 | 215792676 |
| 7EH42CX-**+TDR | 80G2UH110CE20* | 16.0 | 13.4 | 7.8 | 16,500 | 215792677 |
| 7EH42CX-**+TDR | 80G2UH110CE20L* | 16.0 | 13.4 | 7.8 | 16,500 | 215792678 |
| 7AH2AE42PX | - | 16.0 | 13.2 | 7.8 | 16,300 | 215867865 |
| 7AH2AV42PXC | - | 16.0 | 13.4 | 7.8 | 16,300 | 215867866 |
| 7AH2AE42PX | - | 16.0 | 13.2 | 7.8 | 16,300 | 215867870 |
| 7AH2AV42PXC | - | 16.0 | 13.4 | 7.8 | 16,300 | 215867871 |
| 7AH2AE42PX | - | 16.0 | 13.2 | 7.8 | 16,300 | 215867875 |
| 7AH2AV42PXC | - | 16.0 | 13.4 | 7.8 | 16,300 | 215867876 |
| 7AH2AV42PXC | - | 16.0 | 13.4 | 7.8 | 16,300 | 215867881 |
| 7AH2AE42PX | - | 16.0 | 13.2 | 7.8 | 16,300 | 215867880 |
| 7E[C,U]48CX-**+TDR | 80G1UH090CE20* | 15.5 | 13.2 | 7.8 | 16,600 | 215736011 |
| 7E[C,U]48CX-**+TDR | 80G1UH110CE20* | 15.5 | 13.4 | 7.8 | 16,600 | 215736012 |
| 7E[C,U]48CX-**+TDR | 80G2UH110CE16* | 15.5 | 13.4 | 7.8 | 16,500 | 215736007 |
| 7E[C,U]48CX-**+TDR | 97G2UH090CE16* | 15.5 | 13.0 | 7.8 | 16,600 | 215736010 |
| 7E[C,U]48CX-**+TDR | 97G2UH090CE16* | 15.5 | 13.0 | 7.8 | 16,600 | 215736084 |
| 7E[C,U]48CX-**+TDR | 80G1UH090CE20* | 15.5 | 13.2 | 7.8 | 16,600 | 215736085 |
| 7E[C,U]48CX-**+TDR | 92G1UH110CE16* | 15.5 | 13.2 | 7.8 | 16,600 | 215736089 |
| 7EH42CX-**+TDR | 80G1UH110CE20L* | 15.5 | 13.2 | 7.8 | 16,600 | 215735970 |
| 7EH42CX-**+TDR | 80G1UH110CE20* | 15.5 | 13.2 | 7.8 | 16,600 | 215736043 |
| 7EH42CX-**+TDR | 80G1UH110CE20L* | 15.5 | 13.2 | 7.8 | 16,600 | 215736044 |
| 7EH42CX-**+TDR | 92G1UH090CE16* | 15.5 | 13.0 | 7.8 | 16,700 | 215736046 |
| 7EH42CX-**+TDR | 92G1UH110CE16* | 15.5 | 13.2 | 7.8 | 16,400 | 215736047 |
| 7EH42CX-**+TDR | 92G1UH110CE20* | 15.5 | 13.0 | 7.8 | 16,800 | 215736048 |
| 7EH42CX-**+TDR | 96G1UH090CE16* | 15.5 | 13.0 | 7.8 | 16,700 | 215736049 |
| 7EH42BX-**+TDR | 80G1UH070BE12* | 15.5 | 13.0 | 7.8 | 16,600 | 215736100 |
| 7EH42BX-**+TDR | 80G1UH070BE12L* | 15.5 | 13.0 | 7.8 | 16,600 | 215736101 |
| 7EH42BX-**+TDR | 80G1UH090BE16* | 15.5 | 13.2 | 7.8 | 16,600 | 215736102 |
| 7EH42BX-**+TDR | 80G1UH090BE16L* | 15.5 | 13.2 | 7.8 | 16,600 | 215736103 |
| 7E[C,U]48CX-**+TDR | 80G2UH110CE16* | 15.5 | 13.4 | 7.8 | 16,500 | 215736081 |
| 7EH42BX-**+TDR | 80G2UH090BE12* | 15.5 | 13.0 | 7.8 | 16,800 | 215736021 |
| 7EH42BX-**+TDR | 80G2UH090BE16* | 15.5 | 13.2 | 7.8 | 16,700 | 215736022 |
| 7EH42BX-**+TDR | 80G2UH090BE16L* | 15.5 | 13.2 | 7.8 | 16,700 | 215736023 |
| 7EH42BX-**+TDR | 80G1UH070BE12* | 15.5 | 13.0 | 7.8 | 16,600 | 215736026 |
| 7EH42CX-**+TDR | 92G1UH090CE16* | 15.5 | 13.0 | 7.8 | 16,700 | 215736120 |
| 7EH42CX-**+TDR | 92G1UH110CE16* | 15.5 | 13.2 | 7.8 | 16,400 | 215736121 |
| 7EH42CX-**+TDR | 92G1UH110CE20* | 15.5 | 13.0 | 7.8 | 16,800 | 215736122 |
| 7EH42CX-**+TDR | 96G1UH090CE16* | 15.5 | 13.0 | 7.8 | 16,700 | 215736123 |
| 7EH42CX-**+TDR | 97G2UH090CE16* | 15.5 | 13.0 | 7.8 | 16,800 | 215736114 |
Yearly running cost in 10 large cities
- Phoenix, AZ$1,294/yr
- Miami, FL$1,056/yr
- Houston, TX$1,159/yr
- Atlanta, GA$1,162/yr
- Los Angeles, CA$1,128/yr
- New York, NY$2,763/yr
- Chicago, IL$2,241/yr
- Denver, CO$1,861/yr
- Seattle, WA$1,142/yr
- Minneapolis, MN$2,302/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the Ducane 7HP14F36P-**A?
- The Ducane 7HP14F36P-**A is rated at up to 16.0 SEER2 and 13.4 EER2 for cooling and up to 8.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 135 certified matchups SEER2 ranges from 15.2-16.0.
- Is the Ducane 7HP14F36P-**A good for cold climates?
- It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 3-ton model.
- How much does the Ducane 7HP14F36P-**A cost to run per year?
- At its rated efficiency it costs about $1,056-$2,763 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,294 in Phoenix and $2,302 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the Ducane 7HP14F36P-**A?
- ENERGY STAR lists 135 certified combinations for this outdoor unit. The highest-rated ones use 7E[C,U]48CX-**+TDR, 7EH42CX-**+TDR, 7AH2AE42PX.
- What refrigerant does the Ducane 7HP14F36P-**A use?
- It uses R-454B.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 3 ton models
- Carrier 27SCA536A**3016.0 SEER2 · 8.0 HSPF2
- Frigidaire FSH4BF5M2SX36K16.0 SEER2 · 8.0 HSPF2
- Bryant PH5SAN536**AA16.0 SEER2 · 8.0 HSPF2
- Grandaire W5H5S36*K*AAA16.0 SEER2 · 8.0 HSPF2
- Bryant GH5SAN536**AA16.0 SEER2 · 8.0 HSPF2
- Heil R5H5S36*K*AAA16.0 SEER2 · 8.0 HSPF2
- Bryant 235SAN036**AA16.0 SEER2 · 8.0 HSPF2
- Lennox EL16KP1-036-230A16.0 SEER2 · 8.0 HSPF2
See all 302 3 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of June 29, 2026. How we use the data.