3-ton central heat pump · BH714S Series
AC Pro BH714S36P-**A
Below average cooling and heating efficiency for a 3-ton central heat pump, but not rated for cold climates.
Ranks #252 of 302 3 ton central heat pumps for cooling efficiency, and costs about $1,180 a year to run in a mixed climate like Atlanta.
- SEER2
- 16.0 Cooling efficiency over a seasonBelow average · beats 26%
- HSPF2
- 7.8 Heating efficiency over a seasonBelow average · beats 5%
- EER2
- 13.4 Cooling efficiency on a 95°F dayExcellent · beats 94%
- Heat at 5°F
- 16,900 BTU/h48% of its 47°F outputAverage · beats 51%
A good fit if…
- You want a choice of indoor units - 86 certified pairings.
Think twice if…
- You often see nights below 0°F - it is not cold-climate certified.
- Cooling cost matters most - its SEER2 is below average for central heat pumps.
- You mainly need heat - its HSPF2 is below average for central heat pumps.
- Comfort and noise matter - a single-stage compressor runs only full-on or off.
Details
Specifications
| General | |
|---|---|
| Brand | AC Pro |
| Also sold as | Blueridge, SINCLAIR AIR CONDITIONING |
| Outdoor unit model | BH714S36P-**A |
| Series | BH714S Series |
| Type | Central heat pump |
| Nominal size | 3 ton |
| CompressorVariable-speed units run longer at low power | Single stage |
| Refrigerant | R-454B |
| Connected (smart) capable | No |
| On the market since | October 1, 2024 |
| Last certified | June 29, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 16.0 (range 15.2-16.0) |
| EER2Efficiency at 95°F outdoors | 12.5-13.4 |
| Cooling capacity | 36,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 7.8 |
| Capacity at 47°F | 31,400-35,000 BTU/h |
| Capacity at 17°F | 20,000-21,200 BTU/h |
| Capacity at 5°F | 15,700-16,900 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.90-2.06 |
| ENERGY STAR cold climate | No |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with BC742HCT-**+TDR at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 86 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | Furnace | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|---|
| BC742HCT-**+TDR | B80UR1102E5C | 16.0 | 13.4 | 7.8 | 16,500 | 216371066 |
| BC742HCT-**+TDR | B80UR901E5C | 16.0 | 13.4 | 7.8 | 16,600 | 216371675 |
| BC748[C,U]CT-**+TDR | B80UR1102E5C | 16.0 | 13.4 | 7.8 | 16,500 | 216371036 |
| BC742HCT-**+TDR | B80UR1102E5C | 16.0 | 13.4 | 7.8 | 16,500 | 216371672 |
| BC748[C,U]CT-**+TDR | B80UR1102E5C | 16.0 | 13.4 | 7.8 | 16,500 | 216371642 |
| BC748[C,U]CT-**+TDR | B80UR1102E5C | 16.0 | 13.4 | 7.8 | 16,500 | 216372248 |
| BC742HCT-**+TDR | B80UR1102E5C | 16.0 | 13.4 | 7.8 | 16,500 | 216372278 |
| BC742HCT-**+TDR | B80UR901E5C | 16.0 | 13.4 | 7.8 | 16,600 | 216372281 |
| BC742HCT-**+TDR | B80UR901E5C | 16.0 | 13.4 | 7.8 | 16,600 | 216371069 |
| 7AH2AE42PX | - | 16.0 | 13.2 | 7.8 | 16,300 | 218066444 |
| BC742HCT-**+TDR | B80UR802V4BX | 15.5 | 13.2 | 7.8 | 16,600 | 216371077 |
| BC742HCT-**+TDR | B80UR1002V5CX | 15.5 | 13.0 | 7.8 | 16,800 | 216371078 |
| BC742HBT-**+TDR | B80UR701E3B | 15.5 | 13.0 | 7.8 | 16,600 | 216371055 |
| BC742HBT-**+TDR | B80UR901E4B | 15.5 | 13.2 | 7.8 | 16,600 | 216371056 |
| BC742HCT-**+TDR | B97UR902E4C | 15.5 | 13.0 | 7.8 | 16,800 | 216371067 |
| BC748[C,U]CT-**+TDR | B97UR902E4C | 15.5 | 13.0 | 7.8 | 16,600 | 216371037 |
| BC748[C,U]CT-**+TDR | B80UR901E5C | 15.5 | 13.2 | 7.8 | 16,600 | 216371038 |
| BC748[C,U]CT-**+TDR | B80UR1101E5C | 15.5 | 13.4 | 7.8 | 16,600 | 216371039 |
| BC742HCT-**+TDR | B92UR901E4C | 15.5 | 13.0 | 7.8 | 16,700 | 216371072 |
| BC742HCT-**+TDR | B92UR1101E5C | 15.5 | 13.0 | 7.8 | 16,800 | 216371074 |
| BC748[C,U]CT-**+TDR | B80UR802V4BX | 15.5 | 13.2 | 7.8 | 16,600 | 216371046 |
| BC742HBT-**+TDR | B80UR902E3B | 15.5 | 13.0 | 7.8 | 16,800 | 216371051 |
| BC742HBT-**+TDR | B80UR902E4B | 15.5 | 13.2 | 7.8 | 16,700 | 216371052 |
| BC742HCT-**+TDR | B80UR1101E5C | 15.5 | 13.2 | 7.8 | 16,600 | 216371676 |
| BC742HCT-**+TDR | B92UR901E4C | 15.5 | 13.0 | 7.8 | 16,700 | 216371678 |
| BC742HCT-**+TDR | B92UR1101E4C | 15.5 | 13.2 | 7.8 | 16,400 | 216371679 |
| BC742HCT-**+TDR | B92UR1101E5C | 15.5 | 13.0 | 7.8 | 16,800 | 216371680 |
| BC742HCT-**+TDR | B96UR901E4C | 15.5 | 13.0 | 7.8 | 16,700 | 216371681 |
| BC742HCT-**+TDR | B80UR1002V5CX | 15.5 | 13.0 | 7.8 | 16,800 | 216371684 |
| BC742HCT-**+TDR | B97UR902E4C | 15.5 | 13.0 | 7.8 | 16,800 | 216371673 |
| BC748[C,U]CT-**+TDR | B80UR802V4BX | 15.5 | 13.2 | 7.8 | 16,600 | 216371652 |
| BC748[C,U]CT-**+TDR | B80UR1002V5CX | 15.5 | 13.2 | 7.8 | 16,800 | 216371653 |
| BC742HBT-**+TDR | B80UR902E3B | 15.5 | 13.0 | 7.8 | 16,800 | 216371657 |
| BC748[C,U]CT-**+TDR | B97UR902E4C | 15.5 | 13.0 | 7.8 | 16,600 | 216371643 |
| BC748[C,U]CT-**+TDR | B80UR901E5C | 15.5 | 13.2 | 7.8 | 16,600 | 216371644 |
| BC748[C,U]CT-**+TDR | B80UR1101E5C | 15.5 | 13.4 | 7.8 | 16,600 | 216371645 |
| BC748[C,U]CT-**+TDR | B92UR1101E4C | 15.5 | 13.2 | 7.8 | 16,600 | 216371648 |
| BC742HBT-**+TDR | B80UR902E4B | 15.5 | 13.2 | 7.8 | 16,700 | 216371658 |
| BC742HBT-**+TDR | B80UR701E3B | 15.5 | 13.0 | 7.8 | 16,600 | 216371661 |
| BC742HBT-**+TDR | B80UR901E4B | 15.5 | 13.2 | 7.8 | 16,600 | 216371662 |
| BC748[C,U]CT-**+TDR | B92UR1101E4C | 15.5 | 13.2 | 7.8 | 16,600 | 216372254 |
| BC748[C,U]CT-**+TDR | B80UR1002V5CX | 15.5 | 13.2 | 7.8 | 16,800 | 216372259 |
| BC748[C,U]CT-**+TDR | B80UR802V4BX | 15.5 | 13.2 | 7.8 | 16,600 | 216372258 |
| BC748[C,U]CT-**+TDR | B80UR901E5C | 15.5 | 13.2 | 7.8 | 16,600 | 216372250 |
| BC748[C,U]CT-**+TDR | B80UR1101E5C | 15.5 | 13.4 | 7.8 | 16,600 | 216372251 |
| BC742HBT-**+TDR | B80UR902E3B | 15.5 | 13.0 | 7.8 | 16,800 | 216372263 |
| BC742HBT-**+TDR | B80UR902E4B | 15.5 | 13.2 | 7.8 | 16,700 | 216372264 |
| BC742HBT-**+TDR | B80UR701E3B | 15.5 | 13.0 | 7.8 | 16,600 | 216372267 |
| BC742HBT-**+TDR | B80UR901E4B | 15.5 | 13.2 | 7.8 | 16,600 | 216372268 |
| BC742HCT-**+TDR | B97UR902E4C | 15.5 | 13.0 | 7.8 | 16,800 | 216372279 |
| BC742HCT-**+TDR | B92UR901E4C | 15.5 | 13.0 | 7.8 | 16,700 | 216372284 |
| BC742HCT-**+TDR | B92UR1101E4C | 15.5 | 13.2 | 7.8 | 16,400 | 216372285 |
| BC742HCT-**+TDR | B92UR1101E5C | 15.5 | 13.0 | 7.8 | 16,800 | 216372286 |
| BC742HCT-**+TDR | B80UR802V4BX | 15.5 | 13.2 | 7.8 | 16,600 | 216372289 |
| BC742HCT-**+TDR | B80UR1002V5CX | 15.5 | 13.0 | 7.8 | 16,800 | 216372290 |
| BC742HCT-**+TDR | B80UR1101E5C | 15.5 | 13.2 | 7.8 | 16,600 | 216372282 |
| BC742HCT-**+TDR | B96UR901E4C | 15.5 | 13.0 | 7.8 | 16,700 | 216372287 |
| BC742HCT-**+TDR | B80UR802V4BX | 15.5 | 13.2 | 7.8 | 16,600 | 216371683 |
| BC748[C,U]CT-**+TDR | B92UR1101E4C | 15.5 | 13.2 | 7.8 | 16,600 | 216371042 |
| BC742HCT-**+TDR | B80UR1101E5C | 15.5 | 13.2 | 7.8 | 16,600 | 216371070 |
Yearly running cost in 10 large cities
- Phoenix, AZ$1,302/yr
- Miami, FL$1,057/yr
- Houston, TX$1,167/yr
- Atlanta, GA$1,180/yr
- Los Angeles, CA$1,148/yr
- New York, NY$2,820/yr
- Chicago, IL$2,289/yr
- Denver, CO$1,903/yr
- Seattle, WA$1,169/yr
- Minneapolis, MN$2,355/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the AC Pro BH714S36P-**A?
- The AC Pro BH714S36P-**A is rated at up to 16.0 SEER2 and 13.4 EER2 for cooling and up to 7.8 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 86 certified matchups SEER2 ranges from 15.2-16.0.
- Is the AC Pro BH714S36P-**A good for cold climates?
- It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 3-ton model.
- How much does the AC Pro BH714S36P-**A cost to run per year?
- At its rated efficiency it costs about $1,057-$2,820 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,302 in Phoenix and $2,355 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the AC Pro BH714S36P-**A?
- ENERGY STAR lists 86 certified combinations for this outdoor unit. The highest-rated ones use BC742HCT-**+TDR, BC748[C,U]CT-**+TDR, 7AH2AE42PX.
- What refrigerant does the AC Pro BH714S36P-**A use?
- It uses R-454B.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 3 ton models
- WeatherMaker PH5SAN536**AB16.0 SEER2 · 8.0 HSPF2
- Comfort-Aire HSA1436S1-**A16.0 SEER2 · 7.8 HSPF2
- NORDYNE SH4BF5M2SX36K16.0 SEER2 · 8.0 HSPF2
- DuraSTAR DRHP15B36AJ2AN16.0 SEER2 · 7.8 HSPF2
- Maytag PSH4BF5M2SX36K16.0 SEER2 · 8.0 HSPF2
- Friedrich FRP15AY36AJ2N16.0 SEER2 · 7.8 HSPF2
- Lennox EL16KP1-036-230A16.0 SEER2 · 8.0 HSPF2
- Friedrich FWP15AY36AJ2N16.0 SEER2 · 7.8 HSPF2
See all 302 3 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of June 29, 2026. How we use the data.