HVAC Rated

3-ton central heat pump · 15 SEER2 HP

Heil R5H5S36*K*AAA

Below average cooling and heating efficiency for a 3-ton central heat pump, but not rated for cold climates.

Ranks #247 of 302 3 ton central heat pumps for cooling efficiency, and costs about $1,147 a year to run in a mixed climate like Atlanta.

SEER2
16.0 Cooling efficiency over a season
Below average · beats 26%
HSPF2
8.0 Heating efficiency over a season
Below average · beats 12%
EER2
13.0 Cooling efficiency on a 95°F day
Very good · beats 89%
Heat at 5°F
18,100 BTU/h48% of its 47°F output
Very good · beats 80%

A good fit if…

  • You want a choice of indoor units - 312 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • Cooling cost matters most - its SEER2 is below average for central heat pumps.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.
  • Comfort and noise matter - a single-stage compressor runs only full-on or off.

Calculate my running cost

Details

Specifications3 ton, R-454B
General
BrandHeil
Also sold asAirquest, Arcoaire, Comfortmaker, Day & Night, Keeprite, Tempstar, Kenmore, Smart Comfort, MARATHERM, ACIQ
Outdoor unit modelR5H5S36*K*AAA
Series15 SEER2 HP
TypeCentral heat pump
Nominal size3 ton
CompressorVariable-speed units run longer at low powerSingle stage
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceJanuary 1, 2024
Last certifiedJuly 16, 2026
Cooling
SEER2Seasonal efficiency, higher is better16.0 (range 15.2-16.0)
EER2Efficiency at 95°F outdoors11.7-13.0
Cooling capacity33,800-36,800 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8-8.0
Capacity at 47°F33,200-36,400 BTU/h
Capacity at 17°F21,000-22,800 BTU/h
Capacity at 5°F16,100-18,100 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.00-2.22
ENERGY STAR cold climateNo
Heating output as it gets colder48% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with FEVA0048**+NAVA54801CK at the standard test temperatures, in BTU/h:

Certified matchups312 indoor units

The same outdoor unit scores differently with each indoor unit. The 60 highest-rated of 312 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitSEER2EER2HSPF2Heat @5°FAHRI ref.
FEVA0048**+NAVA54801CK16.013.08.017,400217051642
FEVA0048**+NAVA54801CK16.013.08.017,400217051644
FEVA0048**+NAVA54801CK16.013.08.017,400217051646
FEVA0048**+NAVA54801CK16.013.08.017,400217051648
FEVA0048**+NAVA54801CK16.013.08.017,400217051650
FEVA0048**+NAVA54801CK16.013.08.017,400217051652
FEVA0048**+NAVA54801CK16.013.08.017,400217051654
FEVA0048**+NAVA54801CK16.013.08.017,400217051656
FEVA0048**+NAVA54801CK16.013.08.017,400217051658
FEVA0048**+NAVA54801CK16.013.08.017,400217051660
FTMA5B48L0C15.512.57.816,700214179942
FTMA5B48L0C15.512.57.816,700214179944
FTMA5B48L0C15.512.57.816,700214179946
FTMA5B48L0C15.512.57.816,700214179948
FTMA5B48L0C15.512.57.816,700214179950
FTMA5B48L0C15.512.57.816,700214179952
FTMA5B48L0C15.512.57.816,700214179954
FTMA5B48L0C15.512.57.816,700214179956
FTMA5B48L0C15.512.57.816,700214179958
FTMA5B48L0C15.512.57.816,700214179960
FHMA5*48L*C15.513.07.817,400214180184
FHMA5*48L*C15.513.07.817,400214180186
FHMA5*48L*C15.513.07.817,400214180188
FHMA5*48L*C15.513.07.817,400214180192
FHMA5*48L*C15.513.07.817,400214180190
FHMA5*48L*C15.513.07.817,400214180194
FHMA5*48L*C15.513.07.817,400214180198
FHMA5*48L*C15.513.07.817,400214180196
FHMA5*48L*C15.513.07.817,400214180202
FHMA5*48L*C15.513.07.817,400214180200
FEVB0048**+NAVA54801CK15.512.57.817,400214277604
FEVB0048**+NAVA54801CK15.512.57.817,400214277607
FEVB0048**+NAVA54801CK15.512.57.817,400214277610
FEVB0048**+NAVA54801CK15.512.57.817,400214277613
FEVB0048**+NAVA54801CK15.512.57.817,400214277616
FEVB0048**+NAVA54801CK15.512.57.817,400214277619
FEVB0048**+NAVA54801CK15.512.57.817,400214277621
FEVB0048**+NAVA54801CK15.512.57.817,400214277624
FEVB0048**+NAVA54801CK15.512.57.817,400214277627
FEVB0048**+NAVA54801CK15.512.57.817,400214277630
FMA5X36**AL15.512.57.817,000214424302
FMA5X36**AL15.512.57.817,000214424294
FMA5X36**AL15.512.57.817,000214424296
FMA5X36**AL15.512.57.817,000214424298
FMA5X36**AL15.512.57.817,000214424300
FMA5X36**AL15.512.57.817,000214424304
FMA5X36**AL15.512.57.817,000214424306
FMA5X36**AL15.512.57.817,000214424308
FMA5X36**AL15.512.57.817,000214424310
FMA5X36**AL15.512.57.817,000214424312
F5MA5*48L*C15.513.07.817,400216464015
F5MA5*48L*C15.513.07.817,400216464003
F5MA5*48L*C15.513.07.817,400216464005
F5MA5*48L*C15.513.07.817,400216464007
F5MA5*48L*C15.513.07.817,400216464009
F5MA5*48L*C15.513.07.817,400216464011
F5MA5*48L*C15.513.07.817,400216464013
F5MA5*48L*C15.513.07.817,400216464017
F5MA5*48L*C15.513.07.817,400216464019
F5MA5*48L*C15.513.07.817,400216464021
Same unit, other model numbers1

These model numbers have exactly the same certified ratings and matchups as the Heil R5H5S36*K*AAA: the same equipment under another brand, or a variant code for voltage, colour or market. Everything on this page applies to them.

Yearly running cost in 10 large cities$1,022-$2,745

At each state's average electricity price and the city's typical heating and cooling hours.

Questions6
What is the SEER2 rating of the Heil R5H5S36*K*AAA?
The Heil R5H5S36*K*AAA is rated at up to 16.0 SEER2 and 13.0 EER2 for cooling and up to 8.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 312 certified matchups SEER2 ranges from 15.2-16.0.
Is the Heil R5H5S36*K*AAA good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 3-ton model.
How much does the Heil R5H5S36*K*AAA cost to run per year?
At its rated efficiency it costs about $1,022-$2,745 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,262 in Phoenix and $2,295 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Is the Heil R5H5S36*K*AAA the same as the Airquest N5H5S36*K*AAA?
Yes, as far as the certified ratings go. ENERGY STAR lists both model numbers with identical efficiency, capacity and matchups, which means the same outdoor unit sold under a different brand or with a minor variant code (voltage, colour or region). The full list is on this page.
Which indoor units work with the Heil R5H5S36*K*AAA?
ENERGY STAR lists 312 certified combinations for this outdoor unit. The highest-rated ones use FEVA0048**+NAVA54801CK, FTMA5B48L0C, FHMA5*48L*C.
What refrigerant does the Heil R5H5S36*K*AAA use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,253/yrYou save $542/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Heil R5H5S36*K*AAA
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,253
Current system, per year
$1,794
You save per year
$542
Payback
24.0 years
Net after 10 years
-$7,584

Cooling $766Heating $487Electricity used: 7,830 kWhSaved vs. a minimum-efficiency heat pump: $123

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 3 ton models

See all 302 3 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of July 16, 2026. How we use the data.