HVAC Rated

18,000 BTU mini-split heat pump · Apex Multi Match Hyper Heat

TCL H18FMHD3XPC

Excellent cooling efficiency and average heating efficiency for a 18,000 BTU mini-split heat pump, and certified for cold climates.

Ranks #10 of 465 18,000 BTU mini-splits for cooling efficiency, and costs about $453 a year to run in a mixed climate like Atlanta.

SEER2
27.0 Cooling efficiency over a season
Excellent · beats 94%
HSPF2
10.0 Heating efficiency over a season
Average · beats 43%
EER2
15.0 Cooling efficiency on a 95°F day
Excellent · beats 91%
Heat at 5°F
19,800 BTU/h99% of its 47°F output
Average · beats 48%

A good fit if…

  • You want low cooling bills - its SEER2 beats 94% of mini-splits.
  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 19,800 BTU/h at 5°F.
  • You want steady temperatures and quiet running - the compressor varies its speed.

Think twice if…

  • Nothing stands out - its ratings have no weak spot for its class.

Calculate my running cost

Details

Specifications18,000 BTU, R-454B
General
BrandTCL
Outdoor unit modelH18FMHD3XPC
SeriesApex Multi Match Hyper Heat
TypeMini-split heat pump
Nominal size18,000 BTU
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceDecember 3, 2025
Last certifiedAugust 20, 2026
Cooling
SEER2Seasonal efficiency, higher is better27.0 (range 21.5-27.0)
EER2Efficiency at 95°F outdoors13.0-15.0
Cooling capacity18,000-20,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better9.0-10.0
Capacity at 47°F18,000-20,000 BTU/h
Capacity at 17°F21,400-23,000 BTU/h
Capacity at 5°F18,900-19,800 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.80-2.00
ENERGY STAR cold climateYes
Heating output as it gets colder99% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its best matchup at the standard test temperatures, in BTU/h:

Certified matchups3 indoor units

The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitSEER2EER2HSPF2Heat @5°FAHRI ref.
- · cold climate27.015.010.019,800218374501
- · cold climate24.314.09.519,300218644506
- · cold climate21.513.09.018,900218644501
Yearly running cost in 10 large cities$335-$1,140

At each state's average electricity price and the city's typical heating and cooling hours.

Questions4
What is the SEER2 rating of the TCL H18FMHD3XPC?
The TCL H18FMHD3XPC is rated at up to 27.0 SEER2 and 15.0 EER2 for cooling and up to 10.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 3 certified matchups SEER2 ranges from 21.5-27.0.
Is the TCL H18FMHD3XPC good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 19,800 BTU/h at 5°F with a COP of 2.00, so it is still 2.0 times as efficient as electric resistance heat at that temperature.
How much does the TCL H18FMHD3XPC cost to run per year?
At its rated efficiency it costs about $335-$1,140 a year in electricity in large U.S. cities, depending on climate and local rates - for example $446 in Phoenix and $978 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
What refrigerant does the TCL H18FMHD3XPC use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $461/yrYou save $519/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump TCL H18FMHD3XPC
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$461
Current system, per year
$980
You save per year
$519
Payback
13.5 years
Net after 10 years
-$1,808

Cooling $248Heating $213Electricity used: 2,878 kWhSaved vs. a minimum-efficiency heat pump: $291

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 18,000 BTU models

See all 465 18,000 BTU mini-splits, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of August 20, 2026. How we use the data.