18,000 BTU mini-split heat pump · T-Pro
TCL TSC-18HA2/I3TI21
Average cooling efficiency and below average heating efficiency for a 18,000 BTU mini-split heat pump, but not rated for cold climates.
Ranks #239 of 465 18,000 BTU mini-splits for cooling efficiency, and costs about $492 a year to run in a mixed climate like Atlanta.
- SEER2
- 22.0 Cooling efficiency over a seasonAverage · beats 48%
- HSPF2
- 9.0 Heating efficiency over a seasonBelow average · beats 10%
- EER2
- 13.0 Cooling efficiency on a 95°F dayAverage · beats 62%
- Heat at 5°F
- 11,900 BTU/h66% of its 47°F outputBelow average · beats 9%
A good fit if…
- You want steady temperatures and quiet running - the compressor varies its speed.
Think twice if…
- You often see nights below 0°F - it is not cold-climate certified.
- You mainly need heat - its HSPF2 is below average for mini-splits.
- You want the newest refrigerant - it uses R-410A, which is being phased down.
Details
Specifications
| General | |
|---|---|
| Brand | TCL |
| Also sold as | ComfortStar, KANIONco, Pioneer, DELLA, ApooDr, AIR-CON, ROVSUN, TURBRO, Live cool, ACEKOOL, FUJIECO, Clima Smart |
| Outdoor unit model | TSC-18HA2/I3TI21 |
| Series | T-Pro |
| Type | Mini-split heat pump |
| Nominal size | 18,000 BTU |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-410A |
| Connected (smart) capable | No |
| On the market since | January 1, 2022 |
| Last certified | May 6, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 22.0 (range 22.0) |
| EER2Efficiency at 95°F outdoors | 13.0 |
| Cooling capacity | 18,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 9.0 |
| Capacity at 47°F | 18,000 BTU/h |
| Capacity at 17°F | 10,000 BTU/h |
| Capacity at 5°F | 11,900 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.80 |
| ENERGY STAR cold climate | No |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with TSC-18HA2/I3TI21-I at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|
| TSC-18HA2/I3TI21-I | 22.0 | 13.0 | 9.0 | 11,900 | 207688891 |
Same unit, other model numbers
These model numbers have exactly the same certified ratings and matchups as the TCL TSC-18HA2/I3TI21: the same equipment under another brand, or a variant code for voltage, colour or market. Everything on this page applies to them.
Yearly running cost in 10 large cities
- Phoenix, AZ$503/yr
- Miami, FL$387/yr
- Houston, TX$452/yr
- Atlanta, GA$492/yr
- Los Angeles, CA$486/yr
- New York, NY$1,218/yr
- Chicago, IL$997/yr
- Denver, CO$836/yr
- Seattle, WA$519/yr
- Minneapolis, MN$1,037/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the TCL TSC-18HA2/I3TI21?
- The TCL TSC-18HA2/I3TI21 is rated at up to 22.0 SEER2 and 13.0 EER2 for cooling and up to 9.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with.
- Is the TCL TSC-18HA2/I3TI21 good for cold climates?
- It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 18,000 BTU model.
- How much does the TCL TSC-18HA2/I3TI21 cost to run per year?
- At its rated efficiency it costs about $387-$1,218 a year in electricity in large U.S. cities, depending on climate and local rates - for example $503 in Phoenix and $1,037 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Is the TCL TSC-18HA2/I3TI21 the same as the ComfortStar CHT18CD-23(O)?
- Yes, as far as the certified ratings go. ENERGY STAR lists 14 model numbers with identical efficiency, capacity and matchups, which means the same outdoor unit sold under a different brand or with a minor variant code (voltage, colour or region). The full list is on this page.
- Which indoor units work with the TCL TSC-18HA2/I3TI21?
- ENERGY STAR lists 1 certified combination for this outdoor unit. The highest-rated one uses TSC-18HA2/I3TI21-I.
- What refrigerant does the TCL TSC-18HA2/I3TI21 use?
- It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 18,000 BTU models
- Deye DWA4-ACDC-18K22.0 SEER2 · 9.0 HSPF2
- Star Air Kontrol SAK-18-OC/220V21.8 SEER2 · 10.7 HSPF2
- DELLA 048-MS-18K2VR-22S-M-OUT · cold climate22.0 SEER2 · 9.5 HSPF2
- MDV MOX430-18HFN10-M1X · cold climate21.7 SEER2 · 12.4 HSPF2
- ComfortStar C32-MZ-2 · cold climate22.0 SEER2 · 9.5 HSPF2
- ACIQ ACIQ-18ZPL-HP230C · cold climate21.7 SEER2 · 12.3 HSPF2
- AUX ASW-H18E3C2/*R3DI-C3 · cold climate22.0 SEER2 · 9.5 HSPF2
- AI AIR CONDITIONING AO25-18N2-M1H · cold climate21.7 SEER2 · 12.3 HSPF2
See all 465 18,000 BTU mini-splits, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of May 6, 2026. How we use the data.