18,000 BTU mini-split heat pump · MSAG series
MDV MOX430-18HFN10-M1X
Average cooling efficiency and excellent heating efficiency for a 18,000 BTU mini-split heat pump, and certified for cold climates.
Ranks #242 of 465 18,000 BTU mini-splits for cooling efficiency, and costs about $407 a year to run in a mixed climate like Atlanta.
- SEER2
- 21.7 Cooling efficiency over a seasonAverage · beats 42%
- HSPF2
- 12.4 Heating efficiency over a seasonExcellent · beats 93%
- EER2
- 13.0 Cooling efficiency on a 95°F dayAverage · beats 62%
- Heat at 5°F
- 18,000 BTU/h100% of its 47°F outputVery good · beats 78%
A good fit if…
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 18,000 BTU/h at 5°F.
- It will heat most of the year - its HSPF2 beats 93% of mini-splits.
- You want steady temperatures and quiet running - the compressor varies its speed.
- You want a choice of indoor units - 17 certified pairings.
Think twice if…
- Nothing stands out - its ratings have no weak spot for its class.
Details
Specifications
| General | |
|---|---|
| Brand | MDV |
| Outdoor unit model | MOX430-18HFN10-M1X |
| Series | MSAG series |
| Type | Mini-split heat pump |
| Nominal size | 18,000 BTU |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-454B |
| Connected (smart) capable | No |
| On the market since | October 12, 2022 |
| Last certified | May 6, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 21.7 (range 18.0-21.7) |
| EER2Efficiency at 95°F outdoors | 12.0-13.0 |
| Cooling capacity | 16,000-18,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 10.0-12.4 |
| Capacity at 47°F | 17,000-20,000 BTU/h |
| Capacity at 17°F | 14,000-18,000 BTU/h |
| Capacity at 5°F | 17,000-18,000 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.86-2.20 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with MSAG11D-18HRFN10-M1 at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|
| MSAG11D-18HRFN10-M1 · cold climate | 21.7 | 13.0 | 10.8 | 18,000 | 214311117 |
| MSEPC-18HRFN10-M1 · cold climate | 21.5 | 12.5 | 11.0 | 18,000 | 214311116 |
| MSEPC-18HRFN10-M1-D · cold climate | 21.4 | 12.5 | 11.0 | 18,000 | 214855567 |
| MCB-18HRFN10-M1 · cold climate | 20.7 | 12.5 | 12.2 | 17,500 | 214855414 |
| MCB-18HRFN10-M1-D · cold climate | 20.6 | 12.5 | 12.2 | 17,500 | 214855568 |
| MUE-18HRFN10-M1 · cold climate | 20.5 | 12.6 | 10.3 | 17,000 | 214855483 |
| MUE-18HRFN10-M1-D · cold climate | 20.4 | 12.5 | 10.3 | 17,000 | 214855571 |
| MFA2-16HRFN10-M1 · cold climate | 20.2 | 12.5 | 10.3 | 17,500 | 214855416 |
| MCA4-18HRFN10-M1 · cold climate | 20.0 | 12.5 | 12.4 | 17,000 | 214855415 |
| MCA4-18HRFN10-M1-D · cold climate | 20.0 | 12.5 | 12.3 | 17,000 | 214855569 |
| MFA2-16HRFN10-M1-D · cold climate | 20.0 | 12.5 | 10.3 | 17,500 | 214855570 |
| MTJ-18HWFN10-M1 · cold climate | 18.5 | 12.1 | 11.1 | 18,000 | 214861928 |
| MTJ-18HWFN10-M1-D · cold climate | 18.4 | 12.0 | 11.1 | 18,000 | 214861943 |
| MVBC-18HWFN10-MB1 · cold climate | 18.2 | 12.0 | 10.1 | 18,000 | 214861528 |
| MTI-18HWFN10-M1 · cold climate | 18.0 | 12.0 | 10.8 | 18,000 | 214855417 |
| MTI-18HWFN10-M1-D · cold climate | 18.0 | 12.0 | 10.5 | 18,000 | 214861942 |
| MVBC-18HWFN10-MB1-D · cold climate | 18.0 | 12.0 | 10.0 | 18,000 | 214861572 |
Yearly running cost in 10 large cities
- Phoenix, AZ$452/yr
- Miami, FL$368/yr
- Houston, TX$405/yr
- Atlanta, GA$407/yr
- Los Angeles, CA$396/yr
- New York, NY$971/yr
- Chicago, IL$788/yr
- Denver, CO$655/yr
- Seattle, WA$402/yr
- Minneapolis, MN$810/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the MDV MOX430-18HFN10-M1X?
- The MDV MOX430-18HFN10-M1X is rated at up to 21.7 SEER2 and 13.0 EER2 for cooling and up to 12.4 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 17 certified matchups SEER2 ranges from 18.0-21.7.
- Is the MDV MOX430-18HFN10-M1X good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 18,000 BTU/h at 5°F with a COP of 2.20, so it is still 2.2 times as efficient as electric resistance heat at that temperature.
- How much does the MDV MOX430-18HFN10-M1X cost to run per year?
- At its rated efficiency it costs about $368-$971 a year in electricity in large U.S. cities, depending on climate and local rates - for example $452 in Phoenix and $810 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the MDV MOX430-18HFN10-M1X?
- ENERGY STAR lists 17 certified combinations for this outdoor unit. The highest-rated ones use MSAG11D-18HRFN10-M1, MSEPC-18HRFN10-M1, MSEPC-18HRFN10-M1-D.
- What refrigerant does the MDV MOX430-18HFN10-M1X use?
- It uses R-454B.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 18,000 BTU models
- Star Air Kontrol SAK-18-OC/220V21.8 SEER2 · 10.7 HSPF2
- ACIQ ACIQ-18ZPL-HP230C · cold climate21.7 SEER2 · 12.3 HSPF2
- TCL TUM-18HA2/I2I22-21ES · cold climate22.0 SEER2 · 9.0 HSPF2
- AI AIR CONDITIONING AO25-18N2-M1H · cold climate21.7 SEER2 · 12.3 HSPF2
- TCL TSC-18HA2/I3TI2122.0 SEER2 · 9.0 HSPF2
- CanAir 4C28SCH18H21 · cold climate21.7 SEER2 · 12.3 HSPF2
- Deye DWA4-ACDC-18K22.0 SEER2 · 9.0 HSPF2
- Cooper&Hunter CH-RHP18-230VO · cold climate21.7 SEER2 · 12.3 HSPF2
See all 465 18,000 BTU mini-splits, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of May 6, 2026. How we use the data.