3-ton central heat pump · SmartSense 23 VS HP
Tempstar B5H3V36*K*AAA
Excellent cooling efficiency and very good heating efficiency for a 3-ton central heat pump, and certified for cold climates.
Ranks #6 of 302 3 ton central heat pumps for cooling efficiency, and costs about $956 a year to run in a mixed climate like Atlanta.
- SEER2
- 22.5 Cooling efficiency over a seasonExcellent · beats 99%
- HSPF2
- 9.5 Heating efficiency over a seasonVery good · beats 70%
- EER2
- 12.5 Cooling efficiency on a 95°F dayVery good · beats 80%
- Heat at 5°F
- 29,600 BTU/h75% of its 47°F outputAverage · beats 58%
A good fit if…
- You want low cooling bills - its SEER2 beats 99% of central heat pumps.
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 29,600 BTU/h at 5°F.
- It will heat most of the year - its HSPF2 beats 70% of central heat pumps.
- You want steady temperatures and quiet running - the compressor varies its speed.
Think twice if…
- Nothing stands out - its ratings have no weak spot for its class.
Details
Specifications
| General | |
|---|---|
| Brand | Tempstar |
| Also sold as | Kenmore, Keeprite, Day & Night, Comfortmaker, Arcoaire, Airquest, Heil, ACIQ |
| Outdoor unit model | B5H3V36*K*AAA |
| Series | SmartSense 23 VS HP |
| Type | Central heat pump |
| Nominal size | 3 ton |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-454B |
| Connected (smart) capable | No |
| On the market since | November 1, 2024 |
| Last certified | August 5, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 22.5 (range 18.0-22.5) |
| EER2Efficiency at 95°F outdoors | 10.0-12.5 |
| Cooling capacity | 32,000-36,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 8.1-9.5 |
| Capacity at 47°F | 33,400-39,500 BTU/h |
| Capacity at 17°F | 29,200-34,800 BTU/h |
| Capacity at 5°F | 25,200-29,600 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.92-2.10 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with EVM5X61M24A*+WALLCON at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 4,626 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | Furnace | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|---|
| EVM5X61M24A*+WALLCON · cold climate | *80CTL1352422B* | 22.5 | 12.5 | 8.5 | 28,200 | 218411807 |
| EVM5X61M24A*+WALLCON · cold climate | *80CTL1352422B* | 22.5 | 12.5 | 8.5 | 28,200 | 218411806 |
| EVM5X61M24A*+WALLCON · cold climate | *80CTL1352422B* | 22.5 | 12.5 | 8.5 | 28,200 | 218411805 |
| EVM5X61M24A*+WALLCON · cold climate | *80CTL1352422B* | 22.5 | 12.5 | 8.5 | 28,200 | 218411804 |
| EVM5X61M24A*+WALLCON · cold climate | *80CTL1352422B* | 22.5 | 12.5 | 8.5 | 28,200 | 218411803 |
| EVM5X61M24A*+WALLCON · cold climate | *80CTL1352422B* | 22.5 | 12.5 | 8.5 | 28,200 | 218411802 |
| EVM5X61M24A*+WALLCON · cold climate | *80CTL1352422B* | 22.5 | 12.5 | 8.5 | 28,200 | 218411801 |
| EVM5X61M24A*+WALLCON · cold climate | *80CTL1352422B* | 22.5 | 12.5 | 8.5 | 28,200 | 218411800 |
| EVM5X61M24A*+WALLCON · cold climate | *80CTL1102120B* | 22.5 | 12.5 | 8.5 | 28,200 | 218411799 |
| EVM5X61M24A*+WALLCON · cold climate | *80CTL1102120B* | 22.5 | 12.5 | 8.5 | 28,200 | 218411798 |
| EVM5X61M24A*+WALLCON · cold climate | *80CTL1102120B* | 22.5 | 12.5 | 8.5 | 28,200 | 218411797 |
| EVM5X61M24A*+WALLCON · cold climate | *80CTL1102120B* | 22.5 | 12.5 | 8.5 | 28,200 | 218411796 |
| EVM5X61M24A*+WALLCON · cold climate | *80CTL1102120B* | 22.5 | 12.5 | 8.5 | 28,200 | 218411795 |
| EVM5X61M24A*+WALLCON · cold climate | *80CTL1102120B* | 22.5 | 12.5 | 8.5 | 28,200 | 218411794 |
| EVM5X61M24A*+WALLCON · cold climate | *80CTL1102120B* | 22.5 | 12.5 | 8.5 | 28,200 | 218411793 |
| EVM5X61M24A*+WALLCON · cold climate | *80CTL1102120B* | 22.5 | 12.5 | 8.5 | 28,200 | 218411792 |
| EVM5X61M24A*+WALLCON · cold climate | *80CTL0902120B* | 22.5 | 12.5 | 8.5 | 28,200 | 218411791 |
| EVM5X61M24A*+WALLCON · cold climate | *80CTL0902120B* | 22.5 | 12.5 | 8.5 | 28,200 | 218411790 |
| EVM5X61M24A*+WALLCON · cold climate | *80CTL0902120B* | 22.5 | 12.5 | 8.5 | 28,200 | 218411789 |
| EVM5X61M24A*+WALLCON · cold climate | *80CTL0902120B* | 22.5 | 12.5 | 8.5 | 28,200 | 218411788 |
| EVM5X61M24A*+WALLCON · cold climate | *80CTL0902120B* | 22.5 | 12.5 | 8.5 | 28,200 | 218411787 |
| EVM5X61M24A*+WALLCON · cold climate | *80CTL0902120B* | 22.5 | 12.5 | 8.5 | 28,200 | 218411786 |
| EVM5X61M24A*+WALLCON · cold climate | *80CTL0902120B* | 22.5 | 12.5 | 8.5 | 28,200 | 218411785 |
| EVM5X61M24A*+WALLCON · cold climate | *80CTL0902120B* | 22.5 | 12.5 | 8.5 | 28,200 | 218411784 |
| EVD5X61M24A*+WALLCON · cold climate | *95CSU1002122B* | 22.5 | 12.5 | 8.5 | 28,200 | 218413151 |
| EVD5X61M24A*+WALLCON · cold climate | *95CSU1002122B* | 22.5 | 12.5 | 8.5 | 28,200 | 218413150 |
| EVD5X61M24A*+WALLCON · cold climate | *95CSU1002122B* | 22.5 | 12.5 | 8.5 | 28,200 | 218413149 |
| EVD5X61M24A*+WALLCON · cold climate | *95CSU1002122B* | 22.5 | 12.5 | 8.5 | 28,200 | 218413148 |
| EVD5X61M24A*+WALLCON · cold climate | *95CSU1002122B* | 22.5 | 12.5 | 8.5 | 28,200 | 218413147 |
| EVD5X61M24A*+WALLCON · cold climate | *95CSU1002122B* | 22.5 | 12.5 | 8.5 | 28,200 | 218413146 |
| EVD5X61M24A*+WALLCON · cold climate | *95CSU1002122B* | 22.5 | 12.5 | 8.5 | 28,200 | 218413145 |
| EVD5X61M24A*+WALLCON · cold climate | *95CSU1002122B* | 22.5 | 12.5 | 8.5 | 28,200 | 218413144 |
| EVD5X61M24A*+WALLCON · cold climate | *80CTL1102120B* | 22.5 | 12.5 | 8.5 | 28,200 | 218413143 |
| EVD5X61M24A*+WALLCON · cold climate | *80CTL1102120B* | 22.5 | 12.5 | 8.5 | 28,200 | 218413142 |
| EVD5X61M24A*+WALLCON · cold climate | *80CTL1102120B* | 22.5 | 12.5 | 8.5 | 28,200 | 218413141 |
| EVD5X61M24A*+WALLCON · cold climate | *80CTL1102120B* | 22.5 | 12.5 | 8.5 | 28,200 | 218413140 |
| EVD5X61M24A*+WALLCON · cold climate | *80CTL1102120B* | 22.5 | 12.5 | 8.5 | 28,200 | 218413139 |
| EVD5X61M24A*+WALLCON · cold climate | *80CTL1102120B* | 22.5 | 12.5 | 8.5 | 28,200 | 218413138 |
| EVD5X61M24A*+WALLCON · cold climate | *80CTL1102120B* | 22.5 | 12.5 | 8.5 | 28,200 | 218413137 |
| EVD5X61M24A*+WALLCON · cold climate | *80CTL1102120B* | 22.5 | 12.5 | 8.5 | 28,200 | 218413136 |
| EVD5X61M24A*+WALLCON · cold climate | *80CTL0902120B* | 22.5 | 12.5 | 8.5 | 28,200 | 218413135 |
| EVD5X61M24A*+WALLCON · cold climate | *80CTL0902120B* | 22.5 | 12.5 | 8.5 | 28,200 | 218413134 |
| EVD5X61M24A*+WALLCON · cold climate | *80CTL0902120B* | 22.5 | 12.5 | 8.5 | 28,200 | 218413133 |
| EVD5X61M24A*+WALLCON · cold climate | *80CTL0902120B* | 22.5 | 12.5 | 8.5 | 28,200 | 218413132 |
| EVD5X61M24A*+WALLCON · cold climate | *80CTL0902120B* | 22.5 | 12.5 | 8.5 | 28,200 | 218413131 |
| EVD5X61M24A*+WALLCON · cold climate | *80CTL0902120B* | 22.5 | 12.5 | 8.5 | 28,200 | 218413130 |
| EVD5X61M24A*+WALLCON · cold climate | *80CTL0902120B* | 22.5 | 12.5 | 8.5 | 28,200 | 218413129 |
| EVD5X61M24A*+WALLCON · cold climate | *80CTL0902120B* | 22.5 | 12.5 | 8.5 | 28,200 | 218413128 |
| EVD5X61M24A*+WALLCON · cold climate | *95CSU1002122B* | 22.5 | 12.5 | 8.5 | 28,200 | 218629661 |
| EVD5X61M24A*+WALLCON · cold climate | *80CTL1102120B* | 22.5 | 12.5 | 8.5 | 28,200 | 218629660 |
| EVD5X61M24A*+WALLCON · cold climate | *80CTL0902120B* | 22.5 | 12.5 | 8.5 | 28,200 | 218629659 |
| EVM5X61M24A*+WALLCON · cold climate | *80CTL1352422B* | 22.5 | 12.5 | 8.5 | 28,200 | 218629494 |
| EVM5X61M24A*+WALLCON · cold climate | *80CTL1102120B* | 22.5 | 12.5 | 8.5 | 28,200 | 218629493 |
| EVM5X61M24A*+WALLCON · cold climate | *80CTL0902120B* | 22.5 | 12.5 | 8.5 | 28,200 | 218629492 |
| FCMA5B60L0D*+WALLCON · cold climate | - | 22.0 | 12.5 | 9.5 | 25,200 | 218405887 |
| FCMA5B60L0D*+WALLCON · cold climate | - | 22.0 | 12.5 | 9.5 | 25,200 | 218405886 |
| FCMA5B60L0D*+WALLCON · cold climate | - | 22.0 | 12.5 | 9.5 | 25,200 | 218405885 |
| FCMA5B60L0D*+WALLCON · cold climate | - | 22.0 | 12.5 | 9.5 | 25,200 | 218405884 |
| FCMA5B60L0D*+WALLCON · cold climate | - | 22.0 | 12.5 | 9.5 | 25,200 | 218405883 |
| FCMA5B60L0D*+WALLCON · cold climate | - | 22.0 | 12.5 | 9.5 | 25,200 | 218405882 |
Yearly running cost in 10 large cities
- Phoenix, AZ$957/yr
- Miami, FL$726/yr
- Houston, TX$860/yr
- Atlanta, GA$956/yr
- Los Angeles, CA$949/yr
- New York, NY$2,389/yr
- Chicago, IL$1,960/yr
- Denver, CO$1,646/yr
- Seattle, WA$1,024/yr
- Minneapolis, MN$2,044/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the Tempstar B5H3V36*K*AAA?
- The Tempstar B5H3V36*K*AAA is rated at up to 22.5 SEER2 and 12.5 EER2 for cooling and up to 9.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 4626 certified matchups SEER2 ranges from 18.0-22.5.
- Is the Tempstar B5H3V36*K*AAA good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 29,600 BTU/h at 5°F with a COP of 2.10, so it is still 2.1 times as efficient as electric resistance heat at that temperature.
- How much does the Tempstar B5H3V36*K*AAA cost to run per year?
- At its rated efficiency it costs about $726-$2,389 a year in electricity in large U.S. cities, depending on climate and local rates - for example $957 in Phoenix and $2,044 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the Tempstar B5H3V36*K*AAA?
- ENERGY STAR lists 4626 certified combinations for this outdoor unit. The highest-rated ones use EVM5X61M24A*+WALLCON, EVD5X61M24A*+WALLCON, FCMA5B60L0D*+WALLCON.
- What refrigerant does the Tempstar B5H3V36*K*AAA use?
- It uses R-454B.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 3 ton models
- Heil H5H3V36*K*AAA · cold climate22.5 SEER2 · 9.5 HSPF2
- Comfortmaker C5H3V36*K*AAA · cold climate22.5 SEER2 · 9.5 HSPF2
- LG KUSXB361A · cold climate22.0 SEER2 · 10.3 HSPF2
- Carrier 27VNA336A*030 · cold climate22.5 SEER2 · 9.5 HSPF2
- Trane/American Standard 5HCL9036A1000A · cold climate21.2 SEER2 · 9.2 HSPF2
- LG KUSXA361A · cold climate23.5 SEER2 · 10.5 HSPF2
- Trane 5TWV0X36A1 · cold climate21.0 SEER2 · 10.5 HSPF2
- TOSHIBA CARRIER MCY-MUB0368HS2P-UL · cold climate29.7 SEER2 · 12.2 HSPF2
See all 302 3 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of August 5, 2026. How we use the data.