2-ton central heat pump · Performance 19 SEER2 VS HP

Tempstar N5H9V24*K*AAA

Excellent cooling efficiency and very good heating efficiency for a 2-ton central heat pump, and certified for cold climates.

Ranks #42 of 331 2 ton central heat pumps for cooling efficiency, and costs about $654 a year to run in a mixed climate like Atlanta.

SEER2
19.5 Cooling efficiency over a season
Excellent · beats 91%
HSPF2
10.0 Heating efficiency over a season
Very good · beats 84%
EER2
14.0 Cooling efficiency on a 95°F day
Excellent · beats 98%
Heat at 5°F
22,200 BTU/h95% of its 47°F output
Average · beats 47%

A good fit if…

  • You want low cooling bills - its SEER2 beats 91% of central heat pumps.
  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 22,200 BTU/h at 5°F.
  • It will heat most of the year - its HSPF2 beats 84% of central heat pumps.
  • You want steady temperatures and quiet running - the compressor varies its speed.

Think twice if…

  • Nothing stands out - its ratings have no weak spot for its class.

Calculate my running cost

Details

Specifications2 ton, R-454B
General
BrandTempstar
Also sold asKeeprite, Arcoaire, Airquest, Comfortmaker, Day & Night, Heil, ACIQ
Outdoor unit modelN5H9V24*K*AAA
SeriesPerformance 19 SEER2 VS HP
TypeCentral heat pump
Nominal size2 ton
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceJanuary 14, 2025
Last certifiedOctober 7, 2026
Cooling
SEER2Seasonal efficiency, higher is better19.5 (range 15.2-19.5)
EER2Efficiency at 95°F outdoors11.5-14.0
Cooling capacity22,200-25,400 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better8.0-10.0
Capacity at 47°F22,400-25,800 BTU/h
Capacity at 17°F19,800-25,200 BTU/h
Capacity at 5°F20,000-22,200 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.74-2.02
ENERGY STAR cold climateYes
Heating output as it gets colder95% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with QFVA5D3617X at the standard test temperatures, in BTU/h:

Certified matchups8,720 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 8,720 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
QFVA5D3617X · cold climate-19.514.08.621,200218695503
QFVA5D3617X · cold climate-19.514.08.621,200218695501
QFVA5D3617X · cold climate-19.514.08.621,200218695499
QFVA5D3617X · cold climate-19.514.08.621,200218695497
QFVA5D3617X · cold climate-19.514.08.621,200218695495
QFVA5D3617X · cold climate-19.514.08.621,200218695493
QFVA5D3617X · cold climate-19.514.08.621,200218695491
QFVA5D3617X · cold climate-19.514.08.621,200218822093
EA*5X37M21A · cold climate*80MSU0802120A*19.014.010.021,000217949609
EA*5X37M21A · cold climate*80MSU0802120A*19.014.010.021,000217949611
EA*5X37M21A · cold climate*80MSU0802120A*19.014.010.021,000217949612
EA*5X37M21A · cold climate*80MSU0802120A*19.014.010.021,000217949610
EA*5X37M21A · cold climate*80MSU0802120A*19.014.010.021,000217949613
EA*5X37M21A · cold climate*80MSU0802120A*19.014.010.021,000217949614
EA*5X37M21A · cold climate*80MSU0802120A*19.014.010.021,000217949615
EA*5X37M21A · cold climate*97VTN1002122A*19.014.010.021,000217945525
EA*5X37M21A · cold climate*97VTN1002122A*19.014.010.021,000217945526
EA*5X37M21A · cold climate*97VTN1002122A*19.014.010.021,000217945527
EA*5X37M21A · cold climate*97VTN1002122A*19.014.010.021,000217945528
EA*5X37M21A · cold climate*96VTN1002122B*19.014.010.021,000217945510
EA*5X37M21A · cold climate*96VTN1002122B*19.014.010.021,000217945511
EA*5X37M21A · cold climate*96VTN1002122B*19.014.010.021,000217945512
EA*5X37M21A · cold climate*96VTN1002122B*19.014.010.021,000217945513
EA*5X37M21A · cold climate*96VTN1002122B*19.014.010.021,000217945514
EA*5X37M21A · cold climate*96VTN1002122B*19.014.010.021,000217945515
EA*5X37M21A · cold climate*96VTN1002122B*19.014.010.021,000217945516
EA*5X37M21A · cold climate*97VTN1002122A*19.014.010.021,000217945529
EA*5X37M21A · cold climate*97VTN1002122A*19.014.010.021,000217945530
EA*5X37M21A · cold climate*97VTN1002122A*19.014.010.021,000217945531
EA*5X37M21A · cold climate*80VSL1102122B*19.014.010.021,200217944909
EA*5X37M21A · cold climate*80VSL1102122B*19.014.010.021,200217944910
EA*5X37M21A · cold climate*80VSL1102122B*19.014.010.021,200217944912
EA*5X37M21A · cold climate*80VSL1102122B*19.014.010.021,200217944913
EA*5X37M21A · cold climate*80VSL1102122B*19.014.010.021,200217944911
EA*5X37M21A · cold climate*80VSL1102122B*19.014.010.021,200217944914
EA*5X37M21A · cold climate*80VSL1102122B*19.014.010.021,200217944915
EA*5X37M21A · cold climate*80MSU0601716A*19.014.010.021,000217950977
EA*5X37M21A · cold climate*80MSU0601716A*19.014.010.021,000217950978
EA*5X37M21A · cold climate*80MSU0601716A*19.014.010.021,000217950979
EA*5X37M21A · cold climate*80MSU0601716A*19.014.010.021,000217950980
EA*5X37M21A · cold climate*80MSU0601716A*19.014.010.021,000217950981
EA*5X37M21A · cold climate*80MSU0601716A*19.014.010.021,000217950982
EA*5X37M21A · cold climate*80MSU0601716A*19.014.010.021,000217950983
EA*5X37M21A · cold climate*80MSU0802120A*19.014.010.021,000218019211
EA*5X37M21A · cold climate*80MSU0601716A*19.014.010.021,000218019359
EA*5X37M21A · cold climate*80VSL1102122B*19.014.010.021,200218020551
EA*5X37M21A · cold climate*97VTN1002122A*19.014.010.021,000218020622
EA*5X37M21A · cold climate*96VTN1002122B*19.014.010.021,000218020620
QFVA5D2417X · cold climate-19.013.58.620,800218695487
QFVA5D2417X · cold climate-19.013.58.620,800218695485
QFVA5D2417X · cold climate-19.013.58.620,800218695483
QFVA5D2417X · cold climate-19.013.58.620,800218695481
QFVA5D2417X · cold climate-19.013.58.620,800218695479
QFVA5D2417X · cold climate-19.013.58.620,800218695477
QFVA5D2417X · cold climate-19.013.58.620,800218695475
QFVA5D2417X · cold climate-19.013.58.620,800218822092
EVD5X37M21A · cold climate*80CTL0901716B*19.014.08.521,400217943061
EVD5X37M21A · cold climate*80CTL0901716B*19.014.08.521,400217943062
EVD5X37M21A · cold climate*80CTL0901716B*19.014.08.521,400217943063
EVD5X37M21A · cold climate*80CTL0901716B*19.014.08.521,400217943064
Yearly running cost in 10 large cities$583-$1,565

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Tempstar N5H9V24*K*AAA?
The Tempstar N5H9V24*K*AAA is rated at up to 19.5 SEER2 and 14.0 EER2 for cooling and up to 10.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 8720 certified matchups SEER2 ranges from 15.2-19.5.
Is the Tempstar N5H9V24*K*AAA good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 22,200 BTU/h at 5°F with a COP of 2.02, so it is still 2.0 times as efficient as electric resistance heat at that temperature.
How much does the Tempstar N5H9V24*K*AAA cost to run per year?
At its rated efficiency it costs about $583-$1,565 a year in electricity in large U.S. cities, depending on climate and local rates - for example $720 in Phoenix and $1,308 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Tempstar N5H9V24*K*AAA?
ENERGY STAR lists 8720 certified combinations for this outdoor unit. The highest-rated ones use QFVA5D3617X, EA*5X37M21A, QFVA5D2417X.
What refrigerant does the Tempstar N5H9V24*K*AAA use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $715/yrYou save $543/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Tempstar N5H9V24*K*AAA
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$715
Current system, per year
$1,258
You save per year
$543
Payback
16.6 years
Net after 10 years
-$3,570

Cooling $437Heating $278Electricity used: 4,466 kWhSaved vs. a minimum-efficiency heat pump: $251

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 2 ton models

See all 331 2 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of October 7, 2026. How we use the data.