Ranks #25 of 100 5 ton central heat pumps for cooling efficiency, and costs about $1,699 a year to run in a mixed climate like Atlanta.
- SEER2
- 17.5 Cooling efficiency over a seasonAverage · beats 58%
- HSPF2
- 9.0 Heating efficiency over a seasonAverage · beats 54%
- EER2
- 12.0 Cooling efficiency on a 95°F dayAverage · beats 64%
- Heat at 5°F
- 42,000 BTU/h71% of its 47°F outputVery good · beats 70%
A good fit if…
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 42,000 BTU/h at 5°F.
- You want steady temperatures and quiet running - the compressor varies its speed.
- You want a choice of indoor units - 1,484 certified pairings.
Think twice if…
- Nothing stands out - its ratings have no weak spot for its class.
Details
Specifications
| General | |
|---|---|
| Brand | Tempstar |
| Also sold as | Arcoaire, Airquest, Comfortmaker, Day & Night, Keeprite, Heil |
| Outdoor unit model | Q5H9V60*K*AAA |
| Series | QuietComfort 19 SEER2 VS HP |
| Type | Central heat pump |
| Nominal size | 5 ton |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-454B |
| Connected (smart) capable | No |
| On the market since | October 15, 2025 |
| Last certified | September 30, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 17.5 (range 15.2-17.5) |
| EER2Efficiency at 95°F outdoors | 10.0-12.0 |
| Cooling capacity | 54,000-57,500 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 8.0-9.0 |
| Capacity at 47°F | 56,500-62,000 BTU/h |
| Capacity at 17°F | 48,000-50,500 BTU/h |
| Capacity at 5°F | 39,000-42,000 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.94-2.16 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with QFVA5D6021X at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 1,484 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | Furnace | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|---|
| QFVA5D6021X · cold climate | - | 17.5 | 12.0 | 8.1 | 40,000 | 218695584 |
| QFVA5D6021X · cold climate | - | 17.5 | 12.0 | 8.1 | 40,000 | 218695582 |
| QFVA5D6021X · cold climate | - | 17.5 | 12.0 | 8.1 | 40,000 | 218695580 |
| QFVA5D6021X · cold climate | - | 17.5 | 12.0 | 8.1 | 40,000 | 218695578 |
| QFVA5D6021X · cold climate | - | 17.5 | 12.0 | 8.1 | 40,000 | 218695576 |
| QFVA5D6021X · cold climate | - | 17.5 | 12.0 | 8.1 | 40,000 | 218695574 |
| QFVA5D6021X · cold climate | - | 17.5 | 12.0 | 8.1 | 40,000 | 218695572 |
| FTMA5B60L0D · cold climate | - | 17.0 | 12.0 | 9.0 | 41,000 | 217918392 |
| FTMA5B60L0D · cold climate | - | 17.0 | 12.0 | 9.0 | 41,000 | 217918393 |
| FTMA5B60L0D · cold climate | - | 17.0 | 12.0 | 9.0 | 41,000 | 217918394 |
| FTMA5B60L0D · cold climate | - | 17.0 | 12.0 | 9.0 | 41,000 | 217918395 |
| FTMA5B60L0D · cold climate | - | 17.0 | 12.0 | 9.0 | 41,000 | 217918396 |
| FTMA5B60L0D · cold climate | - | 17.0 | 12.0 | 9.0 | 41,000 | 217918398 |
| FTMA5B60L0D · cold climate | - | 17.0 | 12.0 | 9.0 | 41,000 | 217918397 |
| EA*5X61M24A | *80MSU0802120A* | 16.5 | 11.0 | 8.5 | 40,500 | 217932521 |
| EA*5X61M24A | *80MSU0802120A* | 16.5 | 11.0 | 8.5 | 40,500 | 217932522 |
| EA*5X61M24A | *80MSU0802120A* | 16.5 | 11.0 | 8.5 | 40,500 | 217932523 |
| EA*5X61M24A | *80MSU0802120A* | 16.5 | 11.0 | 8.5 | 40,500 | 217932524 |
| EA*5X61M24A | *80MSU0802120A* | 16.5 | 11.0 | 8.5 | 40,500 | 217932525 |
| EA*5X61M24A | *80MSU0802120A* | 16.5 | 11.0 | 8.5 | 40,500 | 217932526 |
| EA*5X61M24A | *80MSU0802120A* | 16.5 | 11.0 | 8.5 | 40,500 | 217932527 |
| EA*5X61M24A | *80CSU0802120B* | 16.5 | 11.0 | 8.5 | 40,500 | 217932448 |
| EA*5X61M24A | *80CSU0802120B* | 16.5 | 11.0 | 8.5 | 40,500 | 217932449 |
| EA*5X61M24A | *80CSU0802120B* | 16.5 | 11.0 | 8.5 | 40,500 | 217932450 |
| EA*5X61M24A | *80CSU0802120B* | 16.5 | 11.0 | 8.5 | 40,500 | 217932451 |
| EA*5X61M24A | *80CSU0802120B* | 16.5 | 11.0 | 8.5 | 40,500 | 217932452 |
| EA*5X61M24A | *80CSU0802120B* | 16.5 | 11.0 | 8.5 | 40,500 | 217932446 |
| EA*5X61M24A | *80CSU0802120B* | 16.5 | 11.0 | 8.5 | 40,500 | 217932447 |
| EA*5X61M24A | *80VSL1352422B* | 16.0 | 11.0 | 9.0 | 40,500 | 217932506 |
| EA*5X61M24A | *80VSL1352422B* | 16.0 | 11.0 | 9.0 | 40,500 | 217932507 |
| EA*5X61M24A | *80VSL1352422B* | 16.0 | 11.0 | 9.0 | 40,500 | 217932508 |
| EA*5X61M24A | *80VSL1352422B* | 16.0 | 11.0 | 9.0 | 40,500 | 217932509 |
| EA*5X61M24A | *80VSL1352422B* | 16.0 | 11.0 | 9.0 | 40,500 | 217932510 |
| EA*5X61M24A | *80VSL1352422B* | 16.0 | 11.0 | 9.0 | 40,500 | 217932511 |
| EA*5X61M24A | *80VSL1352422B* | 16.0 | 11.0 | 9.0 | 40,500 | 217932512 |
| EA*5X61M24A · cold climate | OLV154F20A | 16.0 | 11.0 | 9.0 | 41,000 | 217933008 |
| EA*5X61M21A · cold climate | *80VSL0902120B* | 16.0 | 11.0 | 9.0 | 41,000 | 217932041 |
| EA*5X61M21A · cold climate | *80VSL0902120B* | 16.0 | 11.0 | 9.0 | 41,000 | 217932043 |
| EA*5X61M21A · cold climate | *80VSL0902120B* | 16.0 | 11.0 | 9.0 | 41,000 | 217932042 |
| EA*5X61M21A · cold climate | *80VSL0902120B* | 16.0 | 11.0 | 9.0 | 41,000 | 217932044 |
| EA*5X61M21A · cold climate | *80VSL0902120B* | 16.0 | 11.0 | 9.0 | 41,000 | 217932045 |
| EA*5X60M24A | *97VTN1002122A* | 16.0 | 11.0 | 9.0 | 40,000 | 217931970 |
| EA*5X60M24A | *97VTN1002122A* | 16.0 | 11.0 | 9.0 | 40,000 | 217931969 |
| EA*5X60M24A | *97VTN1002122A* | 16.0 | 11.0 | 9.0 | 40,000 | 217931971 |
| EA*5X60M24A | *97VTN1002122A* | 16.0 | 11.0 | 9.0 | 40,000 | 217931972 |
| EA*5X61M21A · cold climate | *80VSL0902120B* | 16.0 | 11.0 | 9.0 | 41,000 | 217932046 |
| EA*5X61M21A · cold climate | *80VSL0902120B* | 16.0 | 11.0 | 9.0 | 41,000 | 217932047 |
| EA*5X60M24A · cold climate | *97CTN1202422A* | 16.0 | 11.0 | 9.0 | 40,500 | 217931861 |
| EA*5X60M24A · cold climate | *97CTN1202422A* | 16.0 | 11.0 | 9.0 | 40,500 | 217931862 |
| EA*5X60M24A · cold climate | *97CTN1202422A* | 16.0 | 11.0 | 9.0 | 40,500 | 217931863 |
| EA*5X60M24A · cold climate | *97CTN1202422A* | 16.0 | 11.0 | 9.0 | 40,500 | 217931864 |
| EA*5X60M24A · cold climate | *97CTN1202422A* | 16.0 | 11.0 | 9.0 | 40,500 | 217931865 |
| EA*5X60M24A · cold climate | *97CTN1202422A* | 16.0 | 11.0 | 9.0 | 40,500 | 217931866 |
| EA*5X60M24A · cold climate | *97CTN1202422A* | 16.0 | 11.0 | 9.0 | 40,500 | 217931867 |
| EA*5X61M21A · cold climate | *80VSL1102122B* | 16.0 | 11.0 | 9.0 | 41,000 | 217932060 |
| EA*5X61M21A · cold climate | *80VSL1102122B* | 16.0 | 11.0 | 9.0 | 41,000 | 217932056 |
| EA*5X61M21A · cold climate | *80VSL1102122B* | 16.0 | 11.0 | 9.0 | 41,000 | 217932057 |
| EA*5X61M21A · cold climate | *80VSL1102122B* | 16.0 | 11.0 | 9.0 | 41,000 | 217932058 |
| EA*5X61M21A · cold climate | *80VSL1102122B* | 16.0 | 11.0 | 9.0 | 41,000 | 217932059 |
| EA*5X61M21A · cold climate | *80VSL1102122B* | 16.0 | 11.0 | 9.0 | 41,000 | 217932061 |
Yearly running cost in 10 large cities
- Phoenix, AZ$1,852/yr
- Miami, FL$1,492/yr
- Houston, TX$1,660/yr
- Atlanta, GA$1,699/yr
- Los Angeles, CA$1,657/yr
- New York, NY$4,083/yr
- Chicago, IL$3,319/yr
- Denver, CO$2,763/yr
- Seattle, WA$1,701/yr
- Minneapolis, MN$3,421/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the Tempstar Q5H9V60*K*AAA?
- The Tempstar Q5H9V60*K*AAA is rated at up to 17.5 SEER2 and 12.0 EER2 for cooling and up to 9.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 1484 certified matchups SEER2 ranges from 15.2-17.5.
- Is the Tempstar Q5H9V60*K*AAA good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 42,000 BTU/h at 5°F with a COP of 2.16, so it is still 2.2 times as efficient as electric resistance heat at that temperature.
- How much does the Tempstar Q5H9V60*K*AAA cost to run per year?
- At its rated efficiency it costs about $1,492-$4,083 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,852 in Phoenix and $3,421 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the Tempstar Q5H9V60*K*AAA?
- ENERGY STAR lists 1484 certified combinations for this outdoor unit. The highest-rated ones use QFVA5D6021X, FTMA5B60L0D, EA*5X61M24A.
- What refrigerant does the Tempstar Q5H9V60*K*AAA use?
- It uses R-454B.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 5 ton models
- Samsung AC060BXUPCH · cold climate17.5 SEER2 · 9.0 HSPF2
- Bryant 248TAN060**AA17.5 SEER2 · 8.5 HSPF2
- Innovair GOV60H2BA · cold climate17.5 SEER2 · 9.0 HSPF2
- Bryant PH8TAN560**AA17.5 SEER2 · 8.5 HSPF2
- Carrier 27VPA960A*030 · cold climate17.5 SEER2 · 9.0 HSPF2
- Carrier 27TPA860A**3017.5 SEER2 · 8.5 HSPF2
- Bryant 249VAN060**AA · cold climate17.5 SEER2 · 9.0 HSPF2
- Carrier GH8TAN560**AA17.5 SEER2 · 8.5 HSPF2
See all 100 5 ton central heat pumps, ranked