2-ton central heat pump · G Series
TOSOT TUD30-24W2/NHG-D(U)
Very good cooling efficiency and below average heating efficiency for a 2-ton central heat pump, but not rated for cold climates.
Ranks #132 of 331 2 ton central heat pumps for cooling efficiency, and costs about $830 a year to run in a mixed climate like Atlanta.
- SEER2
- 18.2 Cooling efficiency over a seasonVery good · beats 73%
- HSPF2
- 8.3 Heating efficiency over a seasonBelow average · beats 30%
- EER2
- 11.2 Cooling efficiency on a 95°F dayBelow average · beats 28%
- Heat at 5°F
- 19,500 BTU/h79% of its 47°F outputAverage · beats 67%
A good fit if…
- You want low cooling bills - its SEER2 beats 73% of central heat pumps.
- You want steady temperatures and quiet running - the compressor varies its speed.
Think twice if…
- You often see nights below 0°F - it is not cold-climate certified.
- You mainly need heat - its HSPF2 is below average for central heat pumps.
Details
Specifications
| General | |
|---|---|
| Brand | TOSOT |
| Also sold as | GREE, Kinghome, BOREAL, AIR-CON |
| Outdoor unit model | TUD30-24W2/NHG-D(U) |
| Series | G Series |
| Type | Central heat pump |
| Nominal size | 2 ton |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-32 |
| Connected (smart) capable | No |
| On the market since | March 17, 2026 |
| Last certified | September 16, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 18.2 (range 17.5-18.2) |
| EER2Efficiency at 95°F outdoors | 11.2 |
| Cooling capacity | 24,000-27,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 8.3 |
| Capacity at 47°F | 24,000-27,000 BTU/h |
| Capacity at 17°F | 19,600-23,000 BTU/h |
| Capacity at 5°F | 19,000-19,500 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.75-2.14 |
| ENERGY STAR cold climate | No |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with TUD24AH2/NHG-D(U) at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|
| TUD24AH2/NHG-D(U) | 18.2 | 11.2 | 8.3 | 19,000 | 218330465 |
| TUD30AH2/NHG-D(U) | 17.5 | 11.2 | 8.3 | 19,500 | 218330464 |
Same unit, other model numbers
These model numbers have exactly the same certified ratings and matchups as the TOSOT TUD30-24W2/NHG-D(U): the same equipment under another brand, or a variant code for voltage, colour or market. Everything on this page applies to them.
Yearly running cost in 10 large cities
- Phoenix, AZ$883/yr
- Miami, FL$699/yr
- Houston, TX$792/yr
- Atlanta, GA$830/yr
- Los Angeles, CA$814/yr
- New York, NY$2,018/yr
- Chicago, IL$1,645/yr
- Denver, CO$1,373/yr
- Seattle, WA$848/yr
- Minneapolis, MN$1,702/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the TOSOT TUD30-24W2/NHG-D(U)?
- The TOSOT TUD30-24W2/NHG-D(U) is rated at up to 18.2 SEER2 and 11.2 EER2 for cooling and up to 8.3 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 2 certified matchups SEER2 ranges from 17.5-18.2.
- Is the TOSOT TUD30-24W2/NHG-D(U) good for cold climates?
- It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 2-ton model.
- How much does the TOSOT TUD30-24W2/NHG-D(U) cost to run per year?
- At its rated efficiency it costs about $699-$2,018 a year in electricity in large U.S. cities, depending on climate and local rates - for example $883 in Phoenix and $1,702 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Is the TOSOT TUD30-24W2/NHG-D(U) the same as the GREE GUD30W2/NHG-D(U)?
- Yes, as far as the certified ratings go. ENERGY STAR lists 6 model numbers with identical efficiency, capacity and matchups, which means the same outdoor unit sold under a different brand or with a minor variant code (voltage, colour or region). The full list is on this page.
- Which indoor units work with the TOSOT TUD30-24W2/NHG-D(U)?
- ENERGY STAR lists 2 certified combinations for this outdoor unit. The highest-rated ones use TUD24AH2/NHG-D(U), TUD30AH2/NHG-D(U).
- What refrigerant does the TOSOT TUD30-24W2/NHG-D(U) use?
- It uses R-32.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 2 ton models
- 1HVAC ACIQ-24-EHPD · cold climate18.1 SEER2 · 10.4 HSPF2
- GREE WLUD24W2/NHG-D(U)18.2 SEER2 · 8.3 HSPF2
- AI AIR CONDITIONING AUO18-24N2-M3 · cold climate18.1 SEER2 · 10.4 HSPF2
- Day & Night D5CURAH24AAK · cold climate18.2 SEER2 · 10.4 HSPF2
- ComfortStar CPR3-24CD(O) · cold climate18.1 SEER2 · 10.4 HSPF2
- Carrier 37MURAQ24AA3 · cold climate18.2 SEER2 · 10.4 HSPF2
- Innovair SOV24H2BA · cold climate18.1 SEER2 · 10.4 HSPF2
- ZERO ZSOVA-24HDMB-USHH · cold climate18.3 SEER2 · 10.0 HSPF2
See all 331 2 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of September 16, 2026. How we use the data.