HVAC Rated

4-ton central heat pump · 20 TruComfort Variable Speed Heat Pump

Trane 5TWV0X60A1

Very good cooling efficiency and average heating efficiency for a 4-ton central heat pump, and certified for cold climates.

Ranks #60 of 319 4 ton central heat pumps for cooling efficiency, and costs about $1,499 a year to run in a mixed climate like Atlanta.

SEER2
19.0 Cooling efficiency over a season
Very good · beats 85%
HSPF2
9.4 Heating efficiency over a season
Average · beats 64%
EER2
10.5 Cooling efficiency on a 95°F day
Below average · beats 17%
Heat at 5°F
38,500 BTU/h71% of its 47°F output
Average · beats 58%

A good fit if…

  • You want low cooling bills - its SEER2 beats 85% of central heat pumps.
  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 38,500 BTU/h at 5°F.
  • You want steady temperatures and quiet running - the compressor varies its speed.
  • You want a choice of indoor units - 66 certified pairings.

Think twice if…

  • Nothing stands out - its ratings have no weak spot for its class.

Calculate my running cost

Details

Specifications4 ton, R-454B
General
BrandTrane
Also sold asAmerican Standard
Outdoor unit model5TWV0X60A1
Series20 TruComfort Variable Speed Heat Pump
TypeCentral heat pump
Nominal size4 ton
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceNovember 27, 2024
Last certifiedFebruary 11, 2026
Cooling
SEER2Seasonal efficiency, higher is better19.0 (range 18.2-19.0)
EER2Efficiency at 95°F outdoors10.0-10.5
Cooling capacity51,500-54,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better9.0-9.4
Capacity at 47°F52,500-54,000 BTU/h
Capacity at 17°F47,000-48,000 BTU/h
Capacity at 5°F37,600-38,500 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.00-2.10
ENERGY STAR cold climateYes
Heating output as it gets colder71% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with 5PX*D010AS3+P0V0D000M50SD+LRP at the standard test temperatures, in BTU/h:

Certified matchups66 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 66 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
5PX*D010AS3+P0V0D000M50SD+LRP · cold climate-19.010.59.437,800216440466
5PX*D010AS3+P0V0C000M50SD+LRP · cold climate-19.010.59.437,800216440472
5TXCD010AS3+P0V0C000M50SD+LRP · cold climate-19.010.59.437,800216440544
5TXCD010AS3+P0V0D000M50SD+LRP · cold climate-19.010.59.437,800216440554
5PX*D010AS3 · cold climateL8V1C100U5VSB+LRP19.010.59.038,500216440468
5TXCD010AS3 · cold climateL8V1C100U5VSB+LRP19.010.59.038,500216440550
5PX*D010AS3 · cold climateS8V2C080M5PDB19.010.09.038,000216571152
5PX*D010AS3 · cold climateS8V2C080M5PCB19.010.09.038,000216571154
5TXCD010AS3 · cold climateS8V2C080M5PCB19.010.09.038,500216571172
5TXCD010AS3 · cold climateS8V2C080M5PDB19.010.09.038,500216571174
5PX*C009AS3+P0V0C000M50SD+LRP · cold climate-18.810.59.438,000216440436
5PX*D010AS3 · cold climateS9V2D120U5VSB+LRP18.810.59.438,000216440474
5PX*D010AS3 · cold climateS9V2D120U5PSC+LRP18.810.59.438,000216440478
5TXCC009AS3+P0V0C000M50SD+LRP · cold climate-18.810.59.438,000216440520
5TXCD010AS3 · cold climateS9V2D120U5PSC+LRP18.810.59.438,000216440542
5PX*D010AS3 · cold climateS8V2D120M5PDB18.810.59.438,000216453239
5PX*D010AS3 · cold climateS8V2D120M5PCB18.810.59.438,000216453243
5TXCD010AS3 · cold climateS8V2D120M5PDB18.810.59.438,000216453271
5TXCD010AS3 · cold climateS8V2D120M5PCB18.810.59.438,000216453275
5PX*CD09AS3+P0V0C000M50SD+LRP · cold climate-18.810.59.037,600216440438
5PX*D010AS3 · cold climateS9V2C100U5PSC+LRP18.810.59.038,000216440462
5PX*D010AS3 · cold climateS9V2C100U5VSB+LRP18.810.59.038,000216440464
5TAMXD07AV51 · cold climate-18.810.59.037,800216440494
5TXCD010AS3 · cold climateS9V2C100U5VSB+LRP18.810.59.038,000216440540
5TXCD010AS3 · cold climateS9V2C100U5PSC+LRP18.810.59.038,000216440548
5PX*C009AS3 · cold climateS9V2C100U5PSC+LRP18.610.59.038,000216440426
5PX*C009AS3 · cold climateL8V1C100U5VSB+LRP18.610.59.038,000216440428
5PX*C009AS3 · cold climateS9V2C080U5VSB+LRP18.610.59.038,000216440430
5PX*C009AS3 · cold climateS9V2C080U5PSC+LRP18.610.59.038,000216440432
5PX*C009AS3 · cold climateS9V2C100U5VSB+LRP18.610.59.038,000216440434
5PX*CD09AS3 · cold climateS9V2C100D5VSB+LRP18.610.59.038,000216440440
5PX*CD09AS3 · cold climateS9V2C100D5PSC+LRP18.610.59.038,000216440442
5PX*D010AS3 · cold climateS9V2C080U5VSB+LRP18.610.59.038,000216440470
5PX*D010AS3 · cold climateS9V2C080U5PSC+LRP18.610.59.038,000216440476
5PX*DD10AS3+P0V0C000M50SD+LRP · cold climate-18.610.59.037,600216440480
5PX*DD10AS3+P0V0D000M50SD+LRP · cold climate-18.610.59.037,600216440484
5TXCC009AS3 · cold climateS9V2C100U5PSC+LRP18.610.59.038,000216440510
5TXCC009AS3 · cold climateS9V2C080U5PSC+LRP18.610.59.038,000216440512
5TXCC009AS3 · cold climateS9V2C080U5VSB+LRP18.610.59.038,000216440514
5TXCC009AS3 · cold climateL8V1C100U5VSB+LRP18.610.59.038,000216440516
5TXCC009AS3 · cold climateS9V2C100U5VSB+LRP18.610.59.038,000216440518
5TXCD010AS3 · cold climateS9V2C080U5VSB+LRP18.610.59.038,000216440546
5TXCD010AS3 · cold climateS9V2C080U5PSC+LRP18.610.59.038,000216440552
5PX*D010AS3 · cold climate*UHMD120CCV5+LRP18.610.09.038,000216571156
5PX*DD10AS3 · cold climate*DHMD120CCV5+LRP18.610.09.038,000216571158
5TXCD010AS3 · cold climate*UHMD120CCV5+LRP18.610.09.038,000216571170
5PX*DD10AS3 · cold climateS9V2C100D5PSC+LRP18.410.09.038,000216440482
5PX*DD10AS3 · cold climateS9V2C100D5VSB+LRP18.410.09.038,000216440486
5PX*DD10AS3 · cold climateS9V2D120D5PSC+LRP18.410.09.037,800216440488
5PX*DD10AS3 · cold climateS9V2D120D5VSB+LRP18.410.09.037,800216440490
5PX*CD09AS3 · cold climateS8V2C100M5PDB18.410.09.038,000216453225
5PX*CD09AS3 · cold climateS8V2C100M5PCB18.410.09.038,000216453227
5PX*D010AS3 · cold climateS8V2C100M5PDB18.410.59.038,000216453237
5PX*D010AS3 · cold climateS8V2C100M5PCB18.410.59.038,000216453241
5TXCC009AS3 · cold climateS8V2C100M5PCB18.410.09.038,000216453257
5TXCC009AS3 · cold climateS8V2C100M5PDB18.410.09.038,000216453259
5TXCD010AS3 · cold climateS8V2C100M5PDB18.410.59.038,000216453269
5TXCD010AS3 · cold climateS8V2C100M5PCB18.410.59.038,000216453273
5PX*C009AS3 · cold climateS8V2C100M5PCB18.410.09.038,000216453221
5PX*C009AS3 · cold climateS8V2C100M5PDB18.410.09.038,000216453223
Same unit, other model numbers1

These model numbers have exactly the same certified ratings and matchups as the Trane 5TWV0X60A1: the same equipment under another brand, or a variant code for voltage, colour or market. Everything on this page applies to them.

Yearly running cost in 10 large cities$1,312-$3,605

At each state's average electricity price and the city's typical heating and cooling hours.

Questions6
What is the SEER2 rating of the Trane 5TWV0X60A1?
The Trane 5TWV0X60A1 is rated at up to 19.0 SEER2 and 10.5 EER2 for cooling and up to 9.4 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 66 certified matchups SEER2 ranges from 18.2-19.0.
Is the Trane 5TWV0X60A1 good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 38,500 BTU/h at 5°F with a COP of 2.10, so it is still 2.1 times as efficient as electric resistance heat at that temperature.
How much does the Trane 5TWV0X60A1 cost to run per year?
At its rated efficiency it costs about $1,312-$3,605 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,631 in Phoenix and $3,022 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Is the Trane 5TWV0X60A1 the same as the American Standard 5A6V0X60A1?
Yes, as far as the certified ratings go. ENERGY STAR lists both model numbers with identical efficiency, capacity and matchups, which means the same outdoor unit sold under a different brand or with a minor variant code (voltage, colour or region). The full list is on this page.
Which indoor units work with the Trane 5TWV0X60A1?
ENERGY STAR lists 66 certified combinations for this outdoor unit. The highest-rated ones use 5PX*D010AS3+P0V0D000M50SD+LRP, 5PX*D010AS3+P0V0C000M50SD+LRP, 5TXCD010AS3+P0V0C000M50SD+LRP.
What refrigerant does the Trane 5TWV0X60A1 use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,625/yrYou save $1,124/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Trane 5TWV0X60A1
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,625
Current system, per year
$2,749
You save per year
$1,124
Payback
17.8 years
Net after 10 years
-$8,761

Cooling $982Heating $643Electricity used: 10,158 kWhSaved vs. a minimum-efficiency heat pump: $486

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 4 ton models

See all 319 4 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of February 11, 2026. How we use the data.