HVAC Rated

4-ton central heat pump · AFFINITY

York YZV60B21

Very good cooling efficiency and below average heating efficiency for a 4-ton central heat pump, but not rated for cold climates.

Ranks #65 of 319 4 ton central heat pumps for cooling efficiency, and costs about $1,560 a year to run in a mixed climate like Atlanta.

SEER2
19.0 Cooling efficiency over a season
Very good · beats 85%
HSPF2
8.5 Heating efficiency over a season
Below average · beats 38%
EER2
12.0 Cooling efficiency on a 95°F day
Average · beats 64%
Heat at 5°F
40,000 BTU/h76% of its 47°F output
Below average · beats 39%

A good fit if…

  • You want low cooling bills - its SEER2 beats 85% of central heat pumps.
  • You want steady temperatures and quiet running - the compressor varies its speed.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.
  • You want the newest refrigerant - it uses R-410A, which is being phased down.

Calculate my running cost

Details

Specifications4 ton, R-410A
General
BrandYork
Outdoor unit modelYZV60B21
SeriesAFFINITY
TypeCentral heat pump
Nominal size4 ton
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-410A
Connected (smart) capableNo
On the market sinceJune 7, 2023
Last certifiedJuly 14, 2026
Cooling
SEER2Seasonal efficiency, higher is better19.0 (range 19.0)
EER2Efficiency at 95°F outdoors12.0
Cooling capacity52,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better8.5
Capacity at 47°F52,500 BTU/h
Capacity at 17°F48,000 BTU/h
Capacity at 5°F40,000 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.00
ENERGY STAR cold climateNo
Heating output as it gets colder76% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with JHVVC60HE4C2N1+CC at the standard test temperatures, in BTU/h:

Certified matchups1 indoor units

The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitSEER2EER2HSPF2Heat @5°FAHRI ref.
JHVVC60HE4C2N1+CC19.012.08.540,000211212440
Yearly running cost in 10 large cities$1,292-$3,813

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the York YZV60B21?
The York YZV60B21 is rated at up to 19.0 SEER2 and 12.0 EER2 for cooling and up to 8.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with.
Is the York YZV60B21 good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 4-ton model.
How much does the York YZV60B21 cost to run per year?
At its rated efficiency it costs about $1,292-$3,813 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,642 in Phoenix and $3,224 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the York YZV60B21?
ENERGY STAR lists 1 certified combination for this outdoor unit. The highest-rated one uses JHVVC60HE4C2N1+CC.
What refrigerant does the York YZV60B21 use?
It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,655/yrYou save $1,034/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump York YZV60B21
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,655
Current system, per year
$2,689
You save per year
$1,034
Payback
18.9 years
Net after 10 years
-$9,157

Cooling $963Heating $692Electricity used: 10,345 kWhSaved vs. a minimum-efficiency heat pump: $409

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 4 ton models

See all 319 4 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of July 14, 2026. How we use the data.