4-ton central heat pump · XV19
Trane 4TWL9048A1
Very good cooling efficiency and average heating efficiency for a 4-ton central heat pump, but not rated for cold climates.
Ranks #64 of 319 4 ton central heat pumps for cooling efficiency, and costs about $1,269 a year to run in a mixed climate like Atlanta.
- SEER2
- 19.0 Cooling efficiency over a seasonVery good · beats 85%
- HSPF2
- 9.0 Heating efficiency over a seasonAverage · beats 54%
- EER2
- 11.7 Cooling efficiency on a 95°F dayAverage · beats 43%
- Heat at 5°F
- - Not reported by the maker
A good fit if…
- You want low cooling bills - its SEER2 beats 85% of central heat pumps.
- You want steady temperatures and quiet running - the compressor varies its speed.
- You want a choice of indoor units - 10 certified pairings.
Think twice if…
- You often see nights below 0°F - it is not cold-climate certified.
- You want the newest refrigerant - it uses R-410A, which is being phased down.
Details
Specifications
| General | |
|---|---|
| Brand | Trane |
| Outdoor unit model | 4TWL9048A1 |
| Series | XV19 |
| Type | Central heat pump |
| Nominal size | 4 ton |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-410A |
| Connected (smart) capable | No |
| On the market since | January 1, 2023 |
| Last certified | December 19, 2025 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 19.0 (range 19.0) |
| EER2Efficiency at 95°F outdoors | 11.7-12.0 |
| Cooling capacity | 47,000-49,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 8.7-9.0 |
| Capacity at 47°F | 42,000-43,500 BTU/h |
| Capacity at 17°F | 30,600-31,800 BTU/h |
| Capacity at 5°F | - |
| COP at 5°F2.0 = twice as efficient as a space heater | - |
| ENERGY STAR cold climate | No |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with 4PX*DU60BS3 at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit and furnace. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | Furnace | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|---|
| 4PX*DU60BS3 | S8V2D120M5PCA | 19.0 | 11.7 | 9.0 | - | 210691769 |
| 4TXCD010DS3 | S8V2D120M5PCA | 19.0 | 11.7 | 9.0 | - | 210691778 |
| 4TXCD010DS3 | P0V0D000M50SC+RP | 19.0 | 12.0 | 9.0 | - | 206912387 |
| 4TXCD008DS3 | P0V0D000M50SC+RP | 19.0 | 12.0 | 9.0 | - | 206912385 |
| 4PX*DD60BS3 | P0V0D000M50SC+RP | 19.0 | 12.0 | 9.0 | - | 206912373 |
| 4PX*DU60BS3 | P0V0D000M50SC+RP | 19.0 | 12.0 | 9.0 | - | 206912380 |
| 4PX*DU48BS3 | P0V0D000M50SC+RP | 19.0 | 12.0 | 9.0 | - | 206912378 |
| 4PX*DU60BS3 | S8V2C100M5PCA | 19.0 | 11.7 | 8.7 | - | 210692157 |
| 4TXCD010DS3 | S8V2C100M5PDA | 19.0 | 11.7 | 8.7 | - | 211088801 |
| 4TXCD010DS3 | S8V2C100M5PCA | 19.0 | 11.7 | 8.7 | - | 210692160 |
Yearly running cost in 10 large cities
- Phoenix, AZ$1,436/yr
- Miami, FL$1,184/yr
- Houston, TX$1,286/yr
- Atlanta, GA$1,269/yr
- Los Angeles, CA$1,227/yr
- New York, NY$2,991/yr
- Chicago, IL$2,421/yr
- Denver, CO$2,006/yr
- Seattle, WA$1,228/yr
- Minneapolis, MN$2,480/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the Trane 4TWL9048A1?
- The Trane 4TWL9048A1 is rated at up to 19.0 SEER2 and 11.7 EER2 for cooling and up to 9.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with.
- Is the Trane 4TWL9048A1 good for cold climates?
- It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 4-ton model.
- How much does the Trane 4TWL9048A1 cost to run per year?
- At its rated efficiency it costs about $1,184-$2,991 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,436 in Phoenix and $2,480 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the Trane 4TWL9048A1?
- ENERGY STAR lists 10 certified combinations for this outdoor unit. The highest-rated ones use 4PX*DU60BS3, 4TXCD010DS3, 4TXCD008DS3.
- What refrigerant does the Trane 4TWL9048A1 use?
- It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 4 ton models
- Multi MFG MSD-48HD-B · cold climate19.0 SEER2 · 9.0 HSPF2
- York YZV60B2119.0 SEER2 · 8.5 HSPF2
- Hisense AUWR-4824P · cold climate19.0 SEER2 · 9.0 HSPF2
- VillaTherm VHP-UCHA-48HDCT-A · cold climate18.5 SEER2 · 10.5 HSPF2
- American Standard 4A6L9048A119.0 SEER2 · 9.0 HSPF2
- UTL UCHA-48HDCT · cold climate18.5 SEER2 · 9.8 HSPF2
- UTL UCHA-48HDCTN2 · cold climate18.5 SEER2 · 9.8 HSPF2
- Luxaire XDV60E2D11 · cold climate18.5 SEER2 · 9.5 HSPF2
See all 319 4 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of December 19, 2025. How we use the data.