HVAC Rated

4-ton central heat pump · 17 Multi-Speed Heat Pump with WeatherGuard Top

Trane 5TWX7060A1

Average cooling and heating efficiency for a 4-ton central heat pump, and certified for cold climates.

Ranks #175 of 319 4 ton central heat pumps for cooling efficiency, and costs about $1,533 a year to run in a mixed climate like Atlanta.

SEER2
17.0 Cooling efficiency over a season
Average · beats 49%
HSPF2
9.0 Heating efficiency over a season
Average · beats 54%
EER2
11.5 Cooling efficiency on a 95°F day
Below average · beats 31%
Heat at 5°F
39,500 BTU/h75% of its 47°F output
Very good · beats 76%

A good fit if…

  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 39,500 BTU/h at 5°F.
  • You want a choice of indoor units - 147 certified pairings.

Think twice if…

  • Nothing stands out - its ratings have no weak spot for its class.

Calculate my running cost

Details

Specifications4 ton, R-454B
General
BrandTrane
Outdoor unit model5TWX7060A1
Series17 Multi-Speed Heat Pump with WeatherGuard Top
TypeCentral heat pump
Nominal size4 ton
CompressorVariable-speed units run longer at low powerTwo-stage
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceJanuary 15, 2025
Last certifiedApril 22, 2026
Cooling
SEER2Seasonal efficiency, higher is better17.0 (range 15.2-17.0)
EER2Efficiency at 95°F outdoors10.0-11.5
Cooling capacity50,500-53,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better8.5-9.0
Capacity at 47°F50,500-52,000 BTU/h
Capacity at 17°F33,400-34,800 BTU/h
Capacity at 5°F38,000-39,500 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.10-2.20
ENERGY STAR cold climateYes
Heating output as it gets colder75% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with 5TEM6D07AV51+TDR at the standard test temperatures, in BTU/h:

Certified matchups147 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 147 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
5TEM6D07AV51+TDR · cold climate-17.011.59.038,000216764517
5PX*D010AS3 · cold climateS8X1C100M5PSC16.511.09.038,500216764501
5PX*D010AS3 · cold climateS8X1C080M5PSC16.511.09.038,500216764502
5PX*D010AS3 · cold climateS9V2D120U5PSC16.511.29.038,500216764505
5PX*D010AS3 · cold climateS9V2C080U5PSC16.511.29.038,500216764506
5PX*D010AS3 · cold climateS9V2D120U5VSB16.511.29.038,500216764507
5PX*D010AS3 · cold climateS8X1D120M5PSC16.511.09.038,500216764508
5TEM6D06AV41+TDR · cold climate-16.511.59.038,000216764516
5TEMCD06AV41+TDR · cold climate-16.511.59.038,000216764518
5TEMCD07AV51+TDR · cold climate-16.511.59.038,000216764519
5TXCD010AS3 · cold climateS8X1C080M5PSC16.511.09.038,500216764533
5TXCD010AS3 · cold climateS8X1C100M5PSC16.511.09.038,500216764534
5TXCD010AS3 · cold climateS9V2D120U5PSC16.511.29.038,500216764535
5TXCD010AS3 · cold climateS9V2C080U5PSC16.511.09.038,500216764536
5TXCD010AS3 · cold climateS9V2D120U5VSB16.511.29.038,500216764538
5TXCD010AS3 · cold climateS8X2C100M5PSC16.511.09.038,500216765117
5TXCD010AS3 · cold climateS8X2C080M5PSC16.511.09.038,500216765116
5TXCD010AS3 · cold climateS8X1C080M5PTC16.511.09.038,500216765118
5TXCD010AS3 · cold climateS8X2C100M5PTC16.511.09.038,500216765120
5TXCD010AS3 · cold climateS8X1C100M5PTC16.511.09.038,500216765122
5TXCD010AS3 · cold climateS8X2C080M5PTC16.511.09.038,500216765123
5PX*D010AS3 · cold climateS8X1D120M5PTC16.511.09.038,500216765090
5PX*D010AS3 · cold climateS8X2D120M5PTC16.511.09.038,500216765091
5PX*D010AS3 · cold climateS8X1C100M5PTC16.511.09.038,500216765092
5PX*D010AS3 · cold climateS8X1C080M5PTC16.511.09.038,500216765093
5PX*D010AS3 · cold climateS8X2D120M5PSC16.511.09.038,500216765094
5PX*D010AS3 · cold climateS8X2C100M5PTC16.511.09.038,500216765095
5PX*D010AS3 · cold climateS8X2C080M5PTC16.511.09.038,500216765096
5PX*D010AS3 · cold climateS8X2C100M5PSC16.511.09.038,500216765097
5PX*D010AS3 · cold climateS8X2C080M5PSC16.511.09.038,500216765098
5PX*D008AS3 · cold climateS8X1D120M5PSC16.511.08.739,000216764496
5PX*D008AS3 · cold climateS8X1C100M5PSC16.510.08.739,000216764497
5TXCD008AS3 · cold climateS8X1C100M5PSC16.510.08.739,000216764521
5TXCD008AS3 · cold climateS8X1D120M5PSC16.511.08.739,000216764522
5TXCD010AS3 · cold climateS8X1D120M5PSC16.511.28.738,500216764537
5TXCD008AS3 · cold climateS8X2C100M5PTC16.510.08.739,000216765110
5TXCD008AS3 · cold climateS8X2D120M5PSC16.511.08.739,000216765112
5TXCD008AS3 · cold climateS8X2C100M5PSC16.510.08.739,000216765113
5TXCD010AS3 · cold climateS8X2D120M5PSC16.511.28.738,500216765115
5TXCD010AS3 · cold climateS8X1D120M5PTC16.511.28.738,500216765119
5TXCD010AS3 · cold climateS8X2D120M5PTC16.511.28.738,500216765121
5PX*D008AS3 · cold climateS8X2C100M5PSC16.510.08.739,000216765081
5PX*D008AS3 · cold climateS8X1C100M5PTC16.510.08.739,000216765083
5PX*D008AS3 · cold climateS8X2D120M5PSC16.511.08.739,000216765085
5PX*D008AS3 · cold climateS8X2C100M5PTC16.510.08.739,000216765086
5PX*D008AS3 · cold climateS8X1D120M5PTC16.511.08.739,000216765088
5PX*D008AS3 · cold climateS8X2D120M5PTC16.511.08.739,000216765089
5TXCD008AS3 · cold climateS8X1D120M5PTC16.511.08.739,000216765107
5TXCD008AS3 · cold climateS8X1C100M5PTC16.510.08.739,000216765108
5PX*D008AS3 · cold climateL8V1C100U5VSB16.011.09.039,000216764491
5PX*D008AS3 · cold climateS9V2D120U5VSB16.011.09.039,000216764492
5PX*D008AS3 · cold climateS9V2D120U5PSC16.011.09.039,000216764493
5PX*D008AS3 · cold climateS9V2C080U5PSC16.011.09.039,000216764495
5PX*D008AS3 · cold climateS8X1C080M5PSC16.011.09.039,000216764498
5PX*D010AS3 · cold climateL8V1C100U5VSB16.011.29.038,500216764509
5PX*DD10AS3 · cold climateS9V2D120D5PSC16.011.09.038,500216764515
5TXCD008AS3 · cold climateS8X1C080M5PSC16.011.09.039,000216764520
5TXCD008AS3 · cold climateL8V1C100U5VSB16.011.09.039,000216764525
5TXCD008AS3 · cold climateS9V2C080U5PSC16.011.09.039,000216764527
5TXCD008AS3 · cold climateS9V2D120U5VSB16.011.09.039,000216764528
Yearly running cost in 10 large cities$1,421-$3,623

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Trane 5TWX7060A1?
The Trane 5TWX7060A1 is rated at up to 17.0 SEER2 and 11.5 EER2 for cooling and up to 9.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 147 certified matchups SEER2 ranges from 15.2-17.0.
Is the Trane 5TWX7060A1 good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 39,500 BTU/h at 5°F with a COP of 2.20, so it is still 2.2 times as efficient as electric resistance heat at that temperature.
How much does the Trane 5TWX7060A1 cost to run per year?
At its rated efficiency it costs about $1,421-$3,623 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,727 in Phoenix and $3,008 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Trane 5TWX7060A1?
ENERGY STAR lists 147 certified combinations for this outdoor unit. The highest-rated ones use 5TEM6D07AV51+TDR, 5PX*D010AS3, 5TEM6D06AV41+TDR.
What refrigerant does the Trane 5TWX7060A1 use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,701/yrYou save $946/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Trane 5TWX7060A1
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,701
Current system, per year
$2,647
You save per year
$946
Payback
20.6 years
Net after 10 years
-$10,037

Cooling $1,066Heating $635Electricity used: 10,631 kWhSaved vs. a minimum-efficiency heat pump: $328

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 4 ton models

See all 319 4 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of April 22, 2026. How we use the data.