HVAC Rated

2.5-ton central heat pump · ZAVA Series

ZERO ZSOVA-30HDMB-USHH

Average cooling efficiency and very good heating efficiency for a 2.5-ton central heat pump, and certified for cold climates.

Ranks #100 of 199 2.5 ton central heat pumps for cooling efficiency, and costs about $913 a year to run in a mixed climate like Atlanta.

SEER2
16.8 Cooling efficiency over a season
Average · beats 45%
HSPF2
10.0 Heating efficiency over a season
Very good · beats 84%
EER2
11.7 Cooling efficiency on a 95°F day
Average · beats 43%
Heat at 5°F
32,600 BTU/h96% of its 47°F output
Below average · beats 29%

A good fit if…

  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 32,600 BTU/h at 5°F.
  • It will heat most of the year - its HSPF2 beats 84% of central heat pumps.
  • You want steady temperatures and quiet running - the compressor varies its speed.

Think twice if…

  • Nothing stands out - its ratings have no weak spot for its class.

Calculate my running cost

Details

Specifications2.5 ton, R-454B
General
BrandZERO
Also sold asSLIMAIR, Senville, Grandaire
Outdoor unit modelZSOVA-30HDMB-USHH
SeriesZAVA Series
TypeCentral heat pump
Nominal size2.5 ton
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceFebruary 10, 2025
Last certifiedMarch 13, 2025
Cooling
SEER2Seasonal efficiency, higher is better16.8 (range 16.8)
EER2Efficiency at 95°F outdoors11.7
Cooling capacity30,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better10.0
Capacity at 47°F34,000 BTU/h
Capacity at 17°F23,800 BTU/h
Capacity at 5°F32,600 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.96
ENERGY STAR cold climateYes
Heating output as it gets colder96% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with ZAVA-30HDMB-US at the standard test temperatures, in BTU/h:

Certified matchups1 indoor units

The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitSEER2EER2HSPF2Heat @5°FAHRI ref.
ZAVA-30HDMB-US · cold climate16.811.710.032,600216980497
Same unit, other model numbers3

These model numbers have exactly the same certified ratings and matchups as the ZERO ZSOVA-30HDMB-USHH: the same equipment under another brand, or a variant code for voltage, colour or market. Everything on this page applies to them.

Yearly running cost in 10 large cities$838-$2,166

At each state's average electricity price and the city's typical heating and cooling hours.

Questions6
What is the SEER2 rating of the ZERO ZSOVA-30HDMB-USHH?
The ZERO ZSOVA-30HDMB-USHH is rated at up to 16.8 SEER2 and 11.7 EER2 for cooling and up to 10.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with.
Is the ZERO ZSOVA-30HDMB-USHH good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 32,600 BTU/h at 5°F with a COP of 1.96, so it is still 2.0 times as efficient as electric resistance heat at that temperature.
How much does the ZERO ZSOVA-30HDMB-USHH cost to run per year?
At its rated efficiency it costs about $838-$2,166 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,023 in Phoenix and $1,802 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Is the ZERO ZSOVA-30HDMB-USHH the same as the SLIMAIR SHC30AH224V?
Yes, as far as the certified ratings go. ENERGY STAR lists 4 model numbers with identical efficiency, capacity and matchups, which means the same outdoor unit sold under a different brand or with a minor variant code (voltage, colour or region). The full list is on this page.
Which indoor units work with the ZERO ZSOVA-30HDMB-USHH?
ENERGY STAR lists 1 certified combination for this outdoor unit. The highest-rated one uses ZAVA-30HDMB-US.
What refrigerant does the ZERO ZSOVA-30HDMB-USHH use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,009/yrYou save $603/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump ZERO ZSOVA-30HDMB-USHH
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,009
Current system, per year
$1,612
You save per year
$603
Payback
19.1 years
Net after 10 years
-$5,470

Cooling $629Heating $381Electricity used: 6,309 kWhSaved vs. a minimum-efficiency heat pump: $237

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 2.5 ton models

See all 199 2.5 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of March 13, 2025. How we use the data.