2.5-ton central heat pump · ML15KSPV Series

Lennox ML15KSPV-030-230A

Average cooling and heating efficiency for a 2.5-ton central heat pump, but not rated for cold climates.

Ranks #101 of 199 2.5 ton central heat pumps for cooling efficiency, and costs about $885 a year to run in a mixed climate like Atlanta.

SEER2
16.7 Cooling efficiency over a season
Average · beats 43%
HSPF2
9.2 Heating efficiency over a season
Average · beats 61%
EER2
11.4 Cooling efficiency on a 95°F day
Below average · beats 30%
Heat at 5°F
20,000 BTU/h63% of its 47°F output
Average · beats 58%

A good fit if…

  • You want steady temperatures and quiet running - the compressor varies its speed.
  • You want a choice of indoor units - 16 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.

Calculate my running cost

Details

Specifications2.5 ton, R-454B
General
BrandLennox
Also sold asGE Appliances, Haier
Outdoor unit modelML15KSPV-030-230A
SeriesML15KSPV Series
TypeCentral heat pump
Nominal size2.5 ton
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceFebruary 6, 2026
Last certifiedSeptember 3, 2026
Cooling
SEER2Seasonal efficiency, higher is better16.7 (range 15.2-16.7)
EER2Efficiency at 95°F outdoors11.0-11.4
Cooling capacity28,800-30,400 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better8.5-9.2
Capacity at 47°F29,800-31,000 BTU/h
Capacity at 17°F22,600-23,400 BTU/h
Capacity at 5°F19,000-20,000 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.80-2.10
ENERGY STAR cold climateNo
Heating output as it gets colder63% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with CBK48MVT-030-230- at the standard test temperatures, in BTU/h:

Certified matchups16 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
CBK48MVT-030-230--16.711.49.219,200218616036
CBK48MVT-036-230--16.611.49.219,300218616037
CBK47UHET-030-230--16.611.19.219,300218616035
CK40[C,U]T-36B-**+TDRML180UH070V36B*16.411.08.520,000218617676
CBK45UHET-036-230--16.311.09.019,500218616033
CBK45UHET-030-230--16.211.08.719,500218616032
CK40HT-36C-**+TDREL297UH110XV48C*16.211.08.719,700218617680
CK40HT-36C-**+TDREL297UH090XV36C*16.211.08.719,700218617678
CK40HT-36C-**+TDRSLP99UH090XV36C*16.211.08.719,700218617675
CK40HT-36C-**+TDRML297UH090XV36C*16.211.08.719,700218730793
CK40[C,U]T-36B-**+TDRSL280UH090V36B*16.211.08.520,000218617677
CK40DT-42B-**+TDREL297DF045XV36B*16.111.08.719,700218617682
CBK45UHVT-036-230--16.011.28.919,400218616034
CBK45UHVT-030-230--16.011.08.819,000218082939
CK40HT-36C-**+TDREL280UH110E48C*15.311.08.619,800218617679
CK40HT-36C-**+TDRML193UH110XE48C*15.211.08.619,800218617681
Same unit, other model numbers2

These model numbers have exactly the same certified ratings and matchups as the Lennox ML15KSPV-030-230A: the same equipment under another brand, or a variant code for voltage, colour or market. Everything on this page applies to them.

Yearly running cost in 10 large cities$825-$2,089

At each state's average electricity price and the city's typical heating and cooling hours.

Questions6
What is the SEER2 rating of the Lennox ML15KSPV-030-230A?
The Lennox ML15KSPV-030-230A is rated at up to 16.7 SEER2 and 11.4 EER2 for cooling and up to 9.2 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 16 certified matchups SEER2 ranges from 15.2-16.7.
Is the Lennox ML15KSPV-030-230A good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 2.5-ton model.
How much does the Lennox ML15KSPV-030-230A cost to run per year?
At its rated efficiency it costs about $825-$2,089 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,001 in Phoenix and $1,733 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Is the Lennox ML15KSPV-030-230A the same as the GE Appliances NS15H30HA5?
Yes, as far as the certified ratings go. ENERGY STAR lists 3 model numbers with identical efficiency, capacity and matchups, which means the same outdoor unit sold under a different brand or with a minor variant code (voltage, colour or region). The full list is on this page.
Which indoor units work with the Lennox ML15KSPV-030-230A?
ENERGY STAR lists 16 certified combinations for this outdoor unit. The highest-rated ones use CBK48MVT-030-230-, CBK48MVT-036-230-, CBK47UHET-030-230-.
What refrigerant does the Lennox ML15KSPV-030-230A use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $985/yrYou save $541/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Lennox ML15KSPV-030-230A
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$985
Current system, per year
$1,526
You save per year
$541
Payback
20.3 years
Net after 10 years
-$5,592

Cooling $620Heating $365Electricity used: 6,156 kWhSaved vs. a minimum-efficiency heat pump: $187

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 2.5 ton models

See all 199 2.5 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of September 3, 2026. How we use the data.