1.5-ton central heat pump · BH714S Series
AC Pro BH714S18P-**A
Average cooling efficiency and below average heating efficiency for a 1.5-ton central heat pump, but not rated for cold climates.
Ranks #90 of 170 1.5 ton central heat pumps for cooling efficiency, and costs about $592 a year to run in a mixed climate like Atlanta.
- SEER2
- 16.5 Cooling efficiency over a seasonAverage · beats 40%
- HSPF2
- 7.8 Heating efficiency over a seasonBelow average · beats 5%
- EER2
- 14.2 Cooling efficiency on a 95°F dayExcellent · beats 100%
- Heat at 5°F
- 8,500 BTU/h46% of its 47°F outputBelow average · beats 39%
A good fit if…
- You want a choice of indoor units - 102 certified pairings.
Think twice if…
- You often see nights below 0°F - it is not cold-climate certified.
- You mainly need heat - its HSPF2 is below average for central heat pumps.
- Comfort and noise matter - a single-stage compressor runs only full-on or off.
Details
Specifications
| General | |
|---|---|
| Brand | AC Pro |
| Also sold as | Blueridge, SINCLAIR AIR CONDITIONING |
| Outdoor unit model | BH714S18P-**A |
| Series | BH714S Series |
| Type | Central heat pump |
| Nominal size | 1.5 ton |
| CompressorVariable-speed units run longer at low power | Single stage |
| Refrigerant | R-454B |
| Connected (smart) capable | No |
| On the market since | October 1, 2024 |
| Last certified | September 30, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 16.5 (range 15.2-16.5) |
| EER2Efficiency at 95°F outdoors | 13.0-14.2 |
| Cooling capacity | 18,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 7.8 |
| Capacity at 47°F | 17,500-18,000 BTU/h |
| Capacity at 17°F | 10,500-11,200 BTU/h |
| Capacity at 5°F | 7,900-8,500 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.86-2.00 |
| ENERGY STAR cold climate | No |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with BC730HAT-**+TDR at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 102 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | Furnace | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|---|
| BC730HAT-**+TDR | B80UR702E3A | 16.5 | 14.2 | 7.8 | 8,200 | 216370781 |
| BC730HAT-**+TDR | B80UR451E3A | 16.5 | 14.0 | 7.8 | 8,100 | 216370782 |
| BC730HAT-**+TDR | B80UR701E3A | 16.5 | 14.0 | 7.8 | 8,100 | 216370783 |
| BC730HAT-**+TDR | B80UR402V3AX | 16.5 | 14.0 | 7.8 | 8,100 | 216370784 |
| BC730HAT-**+TDR | B80UR702E3A | 16.5 | 14.2 | 7.8 | 8,200 | 216371387 |
| BC730HAT-**+TDR | B80UR451E3A | 16.5 | 14.0 | 7.8 | 8,100 | 216371388 |
| BC730HAT-**+TDR | B80UR701E3A | 16.5 | 14.0 | 7.8 | 8,100 | 216371389 |
| BC730HAT-**+TDR | B80UR402V3AX | 16.5 | 14.0 | 7.8 | 8,100 | 216371390 |
| BC730HAT-**+TDR | B80UR702E3A | 16.5 | 14.2 | 7.8 | 8,200 | 216371993 |
| BC730HAT-**+TDR | B80UR451E3A | 16.5 | 14.0 | 7.8 | 8,100 | 216371994 |
| BC730HAT-**+TDR | B80UR701E3A | 16.5 | 14.0 | 7.8 | 8,100 | 216371995 |
| BC730HAT-**+TDR | B80UR402V3AX | 16.5 | 14.0 | 7.8 | 8,100 | 216371996 |
| BC730HAT-**+TDR | B80UR702V3A | 16.5 | 14.2 | 7.8 | 8,200 | 216801627 |
| BC730HAT-**+TDR | B80UR702V3A | 16.5 | 14.2 | 7.8 | 8,200 | 216801561 |
| BC730HAT-**+TDR | B80UR702V3A | 16.5 | 14.2 | 7.8 | 8,200 | 216801693 |
| BC724HBT-**+TDR | B97UR702E3B | 16.0 | 13.6 | 7.8 | 8,200 | 216370769 |
| BC724HBT-**+TDR | B92UR701E3B | 16.0 | 13.8 | 7.8 | 8,300 | 216370772 |
| BAH7V18PT- | - | 16.0 | 13.6 | 7.8 | 8,100 | 216370717 |
| BAH7V24PT- | - | 16.0 | 13.8 | 7.8 | 8,400 | 216370720 |
| BC724HAT-**+TDR | B80UR702E3A | 16.0 | 13.8 | 7.8 | 8,000 | 216370761 |
| BC724HAT-**+TDR | B80UR451E3A | 16.0 | 13.8 | 7.8 | 7,900 | 216370762 |
| BC724HAT-**+TDR | B80UR701E3A | 16.0 | 13.8 | 7.8 | 8,000 | 216370763 |
| BC724HAT-**+TDR | B80UR402V3AX | 16.0 | 13.8 | 7.8 | 8,000 | 216370764 |
| BC724HBT-**+TDR | B95UR601E3BX | 16.0 | 13.8 | 7.8 | 8,300 | 216370766 |
| BC724HBT-**+TDR | B80UR902E3B | 16.0 | 13.8 | 7.8 | 8,300 | 216370767 |
| BC724HBT-**+TDR | B97UR452E3B | 16.0 | 13.8 | 7.8 | 8,300 | 216370768 |
| BC724HBT-**+TDR | B97UR602V3BX | 16.0 | 13.6 | 7.8 | 8,300 | 216370777 |
| BAH7V18PT- | - | 16.0 | 13.6 | 7.8 | 8,100 | 216371323 |
| BAH7E24PT- | - | 16.0 | 13.8 | 7.8 | 8,200 | 216371325 |
| BAH7V24PT- | - | 16.0 | 13.8 | 7.8 | 8,400 | 216371326 |
| BC724HBT-**+TDR | B92UR701E3B | 16.0 | 13.8 | 7.8 | 8,300 | 216371378 |
| BC724HBT-**+TDR | B97UR602V3BX | 16.0 | 13.6 | 7.8 | 8,300 | 216371383 |
| BC724HAT-**+TDR | B80UR451E3A | 16.0 | 13.8 | 7.8 | 7,900 | 216371368 |
| BC724HAT-**+TDR | B80UR701E3A | 16.0 | 13.8 | 7.8 | 8,000 | 216371369 |
| BC724HBT-**+TDR | B97UR452E3B | 16.0 | 13.8 | 7.8 | 8,300 | 216371374 |
| BC724HBT-**+TDR | B97UR702E3B | 16.0 | 13.6 | 7.8 | 8,200 | 216371375 |
| BC724HBT-**+TDR | B80UR701E3B | 16.0 | 13.8 | 7.8 | 8,200 | 216371376 |
| BC724HBT-**+TDR | B92UR451E3B | 16.0 | 13.8 | 7.8 | 8,300 | 216371377 |
| BC724HAT-**+TDR | B80UR402V3AX | 16.0 | 13.8 | 7.8 | 8,000 | 216371370 |
| BC724HBT-**+TDR | B95UR601E3BX | 16.0 | 13.8 | 7.8 | 8,300 | 216371372 |
| BC724HBT-**+TDR | B80UR902E3B | 16.0 | 13.8 | 7.8 | 8,300 | 216371373 |
| BAH7V18PT- | - | 16.0 | 13.6 | 7.8 | 8,100 | 216371929 |
| BAH7E24PT- | - | 16.0 | 13.8 | 7.8 | 8,200 | 216371931 |
| BAH7V24PT- | - | 16.0 | 13.8 | 7.8 | 8,400 | 216371932 |
| BC724HBT-**+TDR | B80UR701E3B | 16.0 | 13.8 | 7.8 | 8,200 | 216371982 |
| BC724HBT-**+TDR | B92UR451E3B | 16.0 | 13.8 | 7.8 | 8,300 | 216371983 |
| BC724HBT-**+TDR | B92UR701E3B | 16.0 | 13.8 | 7.8 | 8,300 | 216371984 |
| BC724HBT-**+TDR | B97UR602V3BX | 16.0 | 13.6 | 7.8 | 8,300 | 216371989 |
| BC724HAT-**+TDR | B80UR702E3A | 16.0 | 13.8 | 7.8 | 8,000 | 216371973 |
| BC724HAT-**+TDR | B80UR451E3A | 16.0 | 13.8 | 7.8 | 7,900 | 216371974 |
| BC724HAT-**+TDR | B80UR701E3A | 16.0 | 13.8 | 7.8 | 8,000 | 216371975 |
| BC724HAT-**+TDR | B80UR402V3AX | 16.0 | 13.8 | 7.8 | 8,000 | 216371976 |
| BC724HBT-**+TDR | B95UR601E3BX | 16.0 | 13.8 | 7.8 | 8,300 | 216371978 |
| BC724HBT-**+TDR | B80UR902E3B | 16.0 | 13.8 | 7.8 | 8,300 | 216371979 |
| BC724HBT-**+TDR | B97UR452E3B | 16.0 | 13.8 | 7.8 | 8,300 | 216371980 |
| BC724HBT-**+TDR | B97UR702E3B | 16.0 | 13.6 | 7.8 | 8,200 | 216371981 |
| BAH7E24PT- | - | 16.0 | 13.8 | 7.8 | 8,200 | 216370719 |
| BC724HBT-**+TDR | B80UR701E3B | 16.0 | 13.8 | 7.8 | 8,200 | 216370770 |
| BC724HBT-**+TDR | B92UR451E3B | 16.0 | 13.8 | 7.8 | 8,300 | 216370771 |
| BC724HAT-**+TDR | B80UR702E3A | 16.0 | 13.8 | 7.8 | 8,000 | 216371367 |
Yearly running cost in 10 large cities
- Phoenix, AZ$641/yr
- Miami, FL$514/yr
- Houston, TX$574/yr
- Atlanta, GA$592/yr
- Los Angeles, CA$578/yr
- New York, NY$1,428/yr
- Chicago, IL$1,162/yr
- Denver, CO$968/yr
- Seattle, WA$596/yr
- Minneapolis, MN$1,199/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the AC Pro BH714S18P-**A?
- The AC Pro BH714S18P-**A is rated at up to 16.5 SEER2 and 14.2 EER2 for cooling and up to 7.8 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 102 certified matchups SEER2 ranges from 15.2-16.5.
- Is the AC Pro BH714S18P-**A good for cold climates?
- It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 1.5-ton model.
- How much does the AC Pro BH714S18P-**A cost to run per year?
- At its rated efficiency it costs about $514-$1,428 a year in electricity in large U.S. cities, depending on climate and local rates - for example $641 in Phoenix and $1,199 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the AC Pro BH714S18P-**A?
- ENERGY STAR lists 102 certified combinations for this outdoor unit. The highest-rated ones use BC730HAT-**+TDR, BC724HBT-**+TDR, BAH7V18PT-.
- What refrigerant does the AC Pro BH714S18P-**A use?
- It uses R-454B.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 1.5 ton models
- Daikin DH6VSA181MA16.5 SEER2 · 8.5 HSPF2
- AIREASE A7HP14F18P-**A16.5 SEER2 · 7.8 HSPF2
- MDV MOX330U-18HFN1-MR016.5 SEER2 · 8.6 HSPF2
- Comfort-Aire HSA1418S1-**A16.5 SEER2 · 7.8 HSPF2
- Innovair SEV18H2R1916.5 SEER2 · 8.6 HSPF2
- Concord 7HP14F18P-**A16.5 SEER2 · 7.8 HSPF2
- Tempstar D5CUHAH18AAK+KSAIC0701230 · cold climate16.5 SEER2 · 9.0 HSPF2
- GE NS16H18SA5-**A16.5 SEER2 · 7.8 HSPF2
See all 170 1.5 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of September 30, 2026. How we use the data.