HVAC Rated

1.5-ton central heat pump · HSA14 Series

Comfort-Aire HSA1418S1-**A

Average cooling efficiency and below average heating efficiency for a 1.5-ton central heat pump, but not rated for cold climates.

Ranks #92 of 170 1.5 ton central heat pumps for cooling efficiency, and costs about $592 a year to run in a mixed climate like Atlanta.

SEER2
16.5 Cooling efficiency over a season
Average · beats 40%
HSPF2
7.8 Heating efficiency over a season
Below average · beats 5%
EER2
14.0 Cooling efficiency on a 95°F day
Excellent · beats 98%
Heat at 5°F
8,500 BTU/h46% of its 47°F output
Below average · beats 39%

A good fit if…

  • You want a choice of indoor units - 40 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.
  • Comfort and noise matter - a single-stage compressor runs only full-on or off.

Calculate my running cost

Details

Specifications1.5 ton, R-454B
General
BrandComfort-Aire
Also sold asCentury
Outdoor unit modelHSA1418S1-**A
SeriesHSA14 Series
TypeCentral heat pump
Nominal size1.5 ton
CompressorVariable-speed units run longer at low powerSingle stage
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceOctober 1, 2024
Last certifiedSeptember 30, 2026
Cooling
SEER2Seasonal efficiency, higher is better16.5 (range 15.2-16.5)
EER2Efficiency at 95°F outdoors13.0-14.0
Cooling capacity18,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8
Capacity at 47°F17,500-18,000 BTU/h
Capacity at 17°F10,500-11,200 BTU/h
Capacity at 5°F7,900-8,500 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.86-2.00
ENERGY STAR cold climateNo
Heating output as it gets colder46% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with 7EH30AX-**+TDR at the standard test temperatures, in BTU/h:

Certified matchups40 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
7EH30AX-**+TDRGUH80C045A3MP*16.514.07.88,100216372545
7EH30AX-**+TDRGUH80C070A3MP*16.514.07.88,100216372546
7EH30AX-**+TDRGUH80C045A3MP*16.514.07.88,100216372651
7EH30AX-**+TDRGUH80C070A3MP*16.514.07.88,100216372652
HMA24VX1*--16.013.87.88,400216372643
7EH24AX-**+TDRGUH80C070A3MP*16.013.87.88,000216372647
7EH24BX-**+TDRGUH80C070B3MP*16.013.87.88,200216372648
7EH24BX-**+TDRGUH92C045B3MP*16.013.87.88,300216372649
7EH24BX-**+TDRGUH92C070B3MP*16.013.87.88,300216372650
HMA18VX1*--16.013.67.88,100216372534
HMA18VX1*--16.013.67.88,100216372640
7EH24AX-**+TDRGUH80C070A3MP*16.013.87.88,000216372541
7EH24AX-**+TDRGUH80C045A3MP*16.013.87.87,900216372540
7EH24BX-**+TDRGUH80C070B3MP*16.013.87.88,200216372542
7EH24BX-**+TDRGUH92C070B3MP*16.013.87.88,300216372544
7EH24BX-**+TDRGUH92C045B3MP*16.013.87.88,300216372543
7EH24AX-**+TDRGUH80C045A3MP*16.013.87.87,900216372646
HMA24VX1*--16.013.87.88,400216372537
7EH24BX-**+TDRGUH97T045B3MP*16.013.67.88,200216498813
7EH24BX-**+TDRGUH97T045B3MP*16.013.67.88,200216498782
7EH24BX-**+TDRGUH97T070B3MP16.013.87.88,200216801497
7EH24BX-**+TDRGUH97T070B3MP16.013.87.88,200216801527
HMA24CX1*--16.013.87.88,200217662726
HMA24CX1*--16.013.87.88,200217662732
7EH24AX-**+TDRGUH80X040A3MP*15.513.67.88,000216372644
7ED30/36BX-**+TDRGDD96C045B3MP*15.513.27.88,400216372550
7EH24AX-**+TDRGUH80X040A3MP*15.513.67.88,000216372538
7EH24AX-**+TDRGUH80X060A3MP*15.513.67.88,000216372539
7ED30/36BX-**+TDRGDD92C045B3MP*15.513.27.88,400216372654
7ED30/36BX-**+TDRGDD92C070B3MP*15.513.27.88,400216372655
7ED30/36BX-**+TDRGDD96C045B3MP*15.513.27.88,400216372656
7EH24AX-**+TDRGUH80X060A3MP*15.513.67.88,000216372645
7ED30/36BX-**+TDRGDD92C045B3MP*15.513.27.88,400216372548
7ED30/36BX-**+TDRGDD92C070B3MP*15.513.27.88,400216372549
7ED30/36BX-**+TDRGDD80C070B3MP*15.213.07.88,400216372547
HMA24PX1*--15.213.27.88,400216372535
HMA24PX1*--15.213.27.88,400216372641
7ED30/36BX-**+TDRGDD80C070B3MP*15.213.07.88,400216372653
7ED30/36BX-**+TDRGDD96C070B4MP*15.213.07.88,500216372657
7ED30/36BX-**+TDRGDD96C070B4MP*15.213.07.88,500216372551
Yearly running cost in 10 large cities$514-$1,428

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Comfort-Aire HSA1418S1-**A?
The Comfort-Aire HSA1418S1-**A is rated at up to 16.5 SEER2 and 14.0 EER2 for cooling and up to 7.8 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 40 certified matchups SEER2 ranges from 15.2-16.5.
Is the Comfort-Aire HSA1418S1-**A good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 1.5-ton model.
How much does the Comfort-Aire HSA1418S1-**A cost to run per year?
At its rated efficiency it costs about $514-$1,428 a year in electricity in large U.S. cities, depending on climate and local rates - for example $641 in Phoenix and $1,199 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Comfort-Aire HSA1418S1-**A?
ENERGY STAR lists 40 certified combinations for this outdoor unit. The highest-rated ones use 7EH30AX-**+TDR, HMA24VX1*-, 7EH24AX-**+TDR.
What refrigerant does the Comfort-Aire HSA1418S1-**A use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $640/yrYou save $285/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Comfort-Aire HSA1418S1-**A
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$640
Current system, per year
$925
You save per year
$285
Payback
24.5 years
Net after 10 years
-$4,147

Cooling $384Heating $256Electricity used: 3,997 kWhSaved vs. a minimum-efficiency heat pump: $69

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 1.5 ton models

See all 170 1.5 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of September 30, 2026. How we use the data.