HVAC Rated

1.5-ton central heat pump · A7HP14F Series

AIREASE A7HP14F18P-**A

Average cooling efficiency and below average heating efficiency for a 1.5-ton central heat pump, but not rated for cold climates.

Ranks #91 of 170 1.5 ton central heat pumps for cooling efficiency, and costs about $592 a year to run in a mixed climate like Atlanta.

SEER2
16.5 Cooling efficiency over a season
Average · beats 40%
HSPF2
7.8 Heating efficiency over a season
Below average · beats 5%
EER2
14.2 Cooling efficiency on a 95°F day
Excellent · beats 100%
Heat at 5°F
8,500 BTU/h46% of its 47°F output
Average · beats 51%

A good fit if…

  • You want a choice of indoor units - 102 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.
  • Comfort and noise matter - a single-stage compressor runs only full-on or off.

Calculate my running cost

Details

Specifications1.5 ton, R-454B
General
BrandAIREASE
Also sold asArmstrong Air
Outdoor unit modelA7HP14F18P-**A
SeriesA7HP14F Series
TypeCentral heat pump
Nominal size1.5 ton
CompressorVariable-speed units run longer at low powerSingle stage
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceOctober 1, 2024
Last certifiedSeptember 30, 2026
Cooling
SEER2Seasonal efficiency, higher is better16.5 (range 15.2-16.5)
EER2Efficiency at 95°F outdoors13.0-14.2
Cooling capacity18,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8
Capacity at 47°F17,500-18,000 BTU/h
Capacity at 17°F10,500-11,200 BTU/h
Capacity at 5°F7,900-8,500 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.86-2.06
ENERGY STAR cold climateNo
Heating output as it gets colder46% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with 7EH30AX-**+TDR at the standard test temperatures, in BTU/h:

Certified matchups102 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 102 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
7EH30AX-**+TDRA80UH2E070A12*16.514.27.88,200215708932
7EH30AX-**+TDRA80UH1E045A12*16.514.07.88,100215708933
7EH30AX-**+TDRA80UH1E070A12*16.514.07.88,100215708934
7EH30AX-**+TDRA80US2V060A12X*16.514.07.88,100215708935
7EH30BX-**+TDRA80US2V090B16*16.514.27.88,200215708953
7EH30AX-**+TDRA80UH2E070A12*16.514.27.88,200215708819
7EH30AX-**+TDRA80UH1E045A12*16.514.07.88,100215708820
7EH30AX-**+TDRA80UH1E070A12*16.514.07.88,100215708821
7EH30AX-**+TDRA80US2V060A12X*16.514.07.88,100215708822
7EH30BX-**+TDRA80US2V090B16*16.514.27.88,200215708840
7EH30AX-**+TDR80G2UH070AV12*16.514.27.88,200216779144
7EH30AX-**+TDR80G2UH070AV12*16.514.27.88,200216779150
7EH24BX-**+TDRA97US2V060B12X*16.013.67.88,300215708927
7EH24BX-**+TDRA98USMV070B12S*16.013.87.88,200215708928
7EH30AX-**+TDRA80UH2E045A12*16.013.87.88,300215708931
7EH30AX-**+TDRA80US2V070A12*16.013.87.88,200215708936
7EH30AX-**+TDRA80US2V070A12L*16.013.87.88,200215708937
7EH24BX-**+TDRA97UH2E070B12S*16.013.67.88,200215708801
7EH24BX-**+TDRA97US2V070B12S*16.013.87.88,300215708802
7EH24BX-**+TDRA80UH1E070B12*16.013.87.88,200215708803
7EH24BX-**+TDRA93UH1E045B12A*16.013.87.88,300215708805
7EH24BX-**+TDRA93UH1E070B12A*16.013.87.88,300215708806
7EH24AX-**+TDRA80UH2E070A12*16.013.87.88,000215708905
7EH24AX-**+TDRA80UH1E045A12*16.013.87.87,900215708906
7EH24AX-**+TDRA80US2V060A12X*16.013.87.88,000215708908
7EH24AX-**+TDRA80UH1E070A12*16.013.87.88,000215708907
7EH24AX-**+TDRA80US2V070A12*16.013.67.88,000215708909
7EH24AX-**+TDRA80US2V070A12L*16.013.67.88,000215708910
7EH24BX-**+TDRA97UH2E070B12S*16.013.67.88,200215708914
7AH1AE24PX--16.013.87.88,200215708747
7AH1AV24PX--16.013.87.88,400215708748
7AH2AV24PXC-16.013.87.88,300215708749
7EH24BX-**+TDRA97US2V070B12S*16.013.87.88,300215708915
7EH24BX-**+TDRA80UH1E070B12*16.013.87.88,200215708916
7EH24BX-**+TDRA80UH2E090B12*16.013.87.88,300215708911
7EH24BX-**+TDRA93UH1E045B12A*16.013.87.88,300215708918
7EH24BX-**+TDRA80US2V090B12*16.013.87.88,200215708924
7EH24BX-**+TDRA80UH2E090B12*16.013.87.88,300215708798
7EH24BX-**+TDRA97UH2E045B12S*16.013.87.88,300215708799
7EH24BX-**+TDRA80US2V090B16*16.013.87.88,300215708925
7EH24AX-**+TDRA80UH2E070A12*16.013.87.88,000215708792
7EH24AX-**+TDRA80UH1E045A12*16.013.87.87,900215708793
7EH24AX-**+TDRA80UH1E070A12*16.013.87.88,000215708794
7EH24AX-**+TDRA80US2V070A12L*16.013.67.88,000215708797
7EH24AX-**+TDRA80US2V070A12*16.013.67.88,000215708796
7EH24BX-**+TDRA80US2V090B12*16.013.87.88,200215708811
7EH24BX-**+TDRA80US2V090B16*16.013.87.88,300215708812
7EH24BX-**+TDRA97US2V060B12X*16.013.67.88,300215708814
7AH1AV18PX--16.013.67.88,100215708858
7AH1AE24PX--16.013.87.88,200215708860
7AH2AV24PXC-16.013.87.88,300215708862
7AH1AV24PX--16.013.87.88,400215708861
7EH30AX-**+TDRA80US2V070A12*16.013.87.88,200215708823
7EH30AX-**+TDRA80US2V070A12L*16.013.87.88,200215708824
7EH24BX-**+TDRA98USMV070B12S*16.013.87.88,200215708815
7EH30AX-**+TDRA80UH2E045A12*16.013.87.88,300215708818
7AH1AV18PX--16.013.67.88,100215708745
7EH24BX-**+TDRA97UH2E045B12S*16.013.87.88,300215708912
7EH24BX-**+TDRA93UH1E070B12A*16.013.87.88,300215708919
7EH24AX-**+TDRA80US2V060A12X*16.013.87.88,000215708795
Yearly running cost in 10 large cities$514-$1,428

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the AIREASE A7HP14F18P-**A?
The AIREASE A7HP14F18P-**A is rated at up to 16.5 SEER2 and 14.2 EER2 for cooling and up to 7.8 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 102 certified matchups SEER2 ranges from 15.2-16.5.
Is the AIREASE A7HP14F18P-**A good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 1.5-ton model.
How much does the AIREASE A7HP14F18P-**A cost to run per year?
At its rated efficiency it costs about $514-$1,428 a year in electricity in large U.S. cities, depending on climate and local rates - for example $641 in Phoenix and $1,199 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the AIREASE A7HP14F18P-**A?
ENERGY STAR lists 102 certified combinations for this outdoor unit. The highest-rated ones use 7EH30AX-**+TDR, 7EH30BX-**+TDR, 7EH24BX-**+TDR.
What refrigerant does the AIREASE A7HP14F18P-**A use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $640/yrYou save $285/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump AIREASE A7HP14F18P-**A
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$640
Current system, per year
$925
You save per year
$285
Payback
24.5 years
Net after 10 years
-$4,147

Cooling $384Heating $256Electricity used: 3,997 kWhSaved vs. a minimum-efficiency heat pump: $69

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 1.5 ton models

See all 170 1.5 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of September 30, 2026. How we use the data.