HVAC Rated

4-ton central heat pump · Deluxe 20 VS Heat Pump

ACIQ H5H0V48*K*AAA

Excellent cooling efficiency and very good heating efficiency for a 4-ton central heat pump, and certified for cold climates.

Ranks #21 of 319 4 ton central heat pumps for cooling efficiency, and costs about $1,350 a year to run in a mixed climate like Atlanta.

SEER2
19.5 Cooling efficiency over a season
Excellent · beats 91%
HSPF2
9.5 Heating efficiency over a season
Very good · beats 70%
EER2
10.5 Cooling efficiency on a 95°F day
Below average · beats 17%
Heat at 5°F
37,600 BTU/h70% of its 47°F output
Very good · beats 76%

A good fit if…

  • You want low cooling bills - its SEER2 beats 91% of central heat pumps.
  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 37,600 BTU/h at 5°F.
  • It will heat most of the year - its HSPF2 beats 70% of central heat pumps.
  • You want steady temperatures and quiet running - the compressor varies its speed.

Think twice if…

  • Nothing stands out - its ratings have no weak spot for its class.

Calculate my running cost

Details

Specifications4 ton, R-454B
General
BrandACIQ
Also sold asArcoaire, Airquest, Heil
Outdoor unit modelH5H0V48*K*AAA
SeriesDeluxe 20 VS Heat Pump
TypeCentral heat pump
Nominal size4 ton
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceJune 12, 2023
Last certifiedMay 12, 2026
Cooling
SEER2Seasonal efficiency, higher is better19.5 (range 15.5-19.5)
EER2Efficiency at 95°F outdoors9.0-10.5
Cooling capacity43,500-49,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better8.5-9.5
Capacity at 47°F47,000-50,000 BTU/h
Capacity at 17°F41,000-47,500 BTU/h
Capacity at 5°F33,000-37,600 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.92-2.20
ENERGY STAR cold climateYes
Heating output as it gets colder70% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with FCMA5B60L0D*+WALLCON at the standard test temperatures, in BTU/h:

Certified matchups1,504 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 1,504 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
FCMA5B60L0D*+WALLCON · cold climate-19.510.59.533,000216633870
EVM5X61M24A*+WALLCON · cold climate*80CTL1102120B*19.510.59.536,600216633935
EVM5X61M24A*+WALLCON · cold climate*80CTL0902120B*19.510.59.536,600216633934
EVM5X61M24A*+WALLCON · cold climate*96CTN1002122B*19.510.59.536,600216633943
EVM5X61M24A*+WALLCON · cold climate*80CTL1352422B*19.510.59.536,600216633936
EVM5X61M24A*+WALLCON · cold climate*97CMN1002122B*19.510.59.536,600216633941
EVM5X61M24A*+WALLCON · cold climate*97CMN1202422B*19.510.59.536,800216633942
EVM5X61M24A*+WALLCON · cold climate*96CTN1202422B*19.510.59.536,600216633944
EVD5X61M21A*+WALLCON · cold climate*80CTL1102120B*19.510.59.536,600216634011
EVD5X61M21A*+WALLCON · cold climate*97CMN1002122B*19.510.59.536,800216634017
EVD5X61M21A*+WALLCON · cold climate*96CTN1002122B*19.510.59.536,800216634019
EVD5X61M24A*+WALLCON · cold climate*80CTL0902120B*19.510.59.536,600216634023
EVD5X61M24A*+WALLCON · cold climate*97CMN1002122B*19.510.59.536,800216634028
EVD5X61M24A*+WALLCON · cold climate*96CTN1002122B*19.510.59.536,800216634030
EVD5X61M24A*+WALLCON · cold climate*97CMN1202422B*19.510.59.536,800216634029
EVD5X61M24A*+WALLCON · cold climate*80CTL1352422B*19.510.59.536,600216634024
EVD5X61M24A*+WALLCON · cold climate*96CTN1202422B*19.510.59.536,600216634031
EVD5X61M21A*+WALLCON · cold climate*80CTL0902120B*19.510.59.536,600216634010
EVM5X61M24A*+WALLCON · cold climate*97CTN1002122A*19.510.59.536,600216634543
EVM5X61M24A*+WALLCON · cold climate*97CTN1202422A*19.510.59.536,600216634544
EVD5X61M24A*+WALLCON · cold climate*97CTN1202422A*19.510.59.536,600216634592
EVD5X61M24A*+WALLCON · cold climate*97CTN1002122A*19.510.59.536,600216634591
EVD5X61M21A*+WALLCON · cold climate*97CTN1002122A*19.510.59.536,800216634586
FCMA5B60L0D*+WALLCON · cold climate-19.510.59.533,000215675347
FCMA5B60L0D*+WALLCON · cold climate-19.510.59.533,000215675345
FCMA5B60L0D*+WALLCON · cold climate-19.510.59.533,000215675346
EVM5X61M24A*+WALLCON · cold climate*80CTL0902120B*19.510.59.536,600215675987
EVM5X61M24A*+WALLCON · cold climate*80CTL0902120B*19.510.59.536,600215675986
EVM5X61M24A*+WALLCON · cold climate*80CTL0902120B*19.510.59.536,600215675985
EVM5X61M24A*+WALLCON · cold climate*80CTL1102120B*19.510.59.536,600215675995
EVM5X61M24A*+WALLCON · cold climate*80CTL1102120B*19.510.59.536,600215675996
EVM5X61M24A*+WALLCON · cold climate*80CTL1102120B*19.510.59.536,600215675997
EVM5X61M24A*+WALLCON · cold climate*80CTL1352422B*19.510.59.536,600215676006
EVM5X61M24A*+WALLCON · cold climate*80CTL1352422B*19.510.59.536,600215676007
EVM5X61M24A*+WALLCON · cold climate*80CTL1352422B*19.510.59.536,600215676005
EVM5X61M24A*+WALLCON · cold climate*97CMN1002122B*19.510.59.536,600215676055
EVM5X61M24A*+WALLCON · cold climate*97CMN1002122B*19.510.59.536,600215676057
EVM5X61M24A*+WALLCON · cold climate*97CMN1002122B*19.510.59.536,600215676056
EVM5X61M24A*+WALLCON · cold climate*97CMN1202422B*19.510.59.536,800215676067
EVM5X61M24A*+WALLCON · cold climate*97CMN1202422B*19.510.59.536,800215676066
EVM5X61M24A*+WALLCON · cold climate*97CMN1202422B*19.510.59.536,800215676065
EVM5X61M24A*+WALLCON · cold climate*96CTN1002122B*19.510.59.536,600215676077
EVM5X61M24A*+WALLCON · cold climate*96CTN1002122B*19.510.59.536,600215676076
EVM5X61M24A*+WALLCON · cold climate*96CTN1002122B*19.510.59.536,600215676075
EVM5X61M24A*+WALLCON · cold climate*96CTN1202422B*19.510.59.536,600215676085
EVM5X61M24A*+WALLCON · cold climate*96CTN1202422B*19.510.59.536,600215676086
EVM5X61M24A*+WALLCON · cold climate*96CTN1202422B*19.510.59.536,600215676087
EVD5X61M21A*+WALLCON · cold climate*80CTL0902120B*19.510.59.536,600215676747
EVD5X61M21A*+WALLCON · cold climate*80CTL0902120B*19.510.59.536,600215676746
EVD5X61M21A*+WALLCON · cold climate*80CTL0902120B*19.510.59.536,600215676745
EVD5X61M21A*+WALLCON · cold climate*80CTL1102120B*19.510.59.536,600215676755
EVD5X61M21A*+WALLCON · cold climate*80CTL1102120B*19.510.59.536,600215676756
EVD5X61M21A*+WALLCON · cold climate*80CTL1102120B*19.510.59.536,600215676757
EVD5X61M21A*+WALLCON · cold climate*97CMN1002122B*19.510.59.536,800215676815
EVD5X61M21A*+WALLCON · cold climate*97CMN1002122B*19.510.59.536,800215676816
EVD5X61M21A*+WALLCON · cold climate*97CMN1002122B*19.510.59.536,800215676817
EVD5X61M21A*+WALLCON · cold climate*96CTN1002122B*19.510.59.536,800215676837
EVD5X61M21A*+WALLCON · cold climate*96CTN1002122B*19.510.59.536,800215676836
EVD5X61M21A*+WALLCON · cold climate*96CTN1002122B*19.510.59.536,800215676835
EVD5X61M24A*+WALLCON · cold climate*80CTL0902120B*19.510.59.536,600215676875
Yearly running cost in 10 large cities$1,148-$3,274

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the ACIQ H5H0V48*K*AAA?
The ACIQ H5H0V48*K*AAA is rated at up to 19.5 SEER2 and 10.5 EER2 for cooling and up to 9.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 1504 certified matchups SEER2 ranges from 15.5-19.5.
Is the ACIQ H5H0V48*K*AAA good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 37,600 BTU/h at 5°F with a COP of 2.20, so it is still 2.2 times as efficient as electric resistance heat at that temperature.
How much does the ACIQ H5H0V48*K*AAA cost to run per year?
At its rated efficiency it costs about $1,148-$3,274 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,443 in Phoenix and $2,757 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the ACIQ H5H0V48*K*AAA?
ENERGY STAR lists 1504 certified combinations for this outdoor unit. The highest-rated ones use FCMA5B60L0D*+WALLCON, EVM5X61M24A*+WALLCON, EVD5X61M21A*+WALLCON.
What refrigerant does the ACIQ H5H0V48*K*AAA use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,447/yrYou save $1,043/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump ACIQ H5H0V48*K*AAA
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,447
Current system, per year
$2,490
You save per year
$1,043
Payback
17.3 years
Net after 10 years
-$7,568

Cooling $857Heating $589Electricity used: 9,043 kWhSaved vs. a minimum-efficiency heat pump: $469

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 4 ton models

See all 319 4 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of May 12, 2026. How we use the data.