HVAC Rated

3-ton central heat pump · A7HP14F Seies

AIREASE A7HP14F36P-**A

Below average cooling and heating efficiency for a 3-ton central heat pump, but not rated for cold climates.

Ranks #239 of 302 3 ton central heat pumps for cooling efficiency, and costs about $1,162 a year to run in a mixed climate like Atlanta.

SEER2
16.0 Cooling efficiency over a season
Below average · beats 26%
HSPF2
8.0 Heating efficiency over a season
Below average · beats 12%
EER2
13.4 Cooling efficiency on a 95°F day
Excellent · beats 94%
Heat at 5°F
16,900 BTU/h48% of its 47°F output
Average · beats 51%

A good fit if…

  • You want a choice of indoor units - 80 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • Cooling cost matters most - its SEER2 is below average for central heat pumps.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.
  • Comfort and noise matter - a single-stage compressor runs only full-on or off.

Calculate my running cost

Details

Specifications3 ton, R-454B
General
BrandAIREASE
Also sold asArmstrong Air
Outdoor unit modelA7HP14F36P-**A
SeriesA7HP14F Seies
TypeCentral heat pump
Nominal size3 ton
CompressorVariable-speed units run longer at low powerSingle stage
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceOctober 1, 2024
Last certifiedJune 29, 2026
Cooling
SEER2Seasonal efficiency, higher is better16.0 (range 15.2-16.0)
EER2Efficiency at 95°F outdoors12.5-13.4
Cooling capacity35,400-36,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8-8.0
Capacity at 47°F31,400-35,600 BTU/h
Capacity at 17°F20,000-21,200 BTU/h
Capacity at 5°F15,700-16,900 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.90-2.06
ENERGY STAR cold climateNo
Heating output as it gets colder48% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with 7EH42CX-**+TDR at the standard test temperatures, in BTU/h:

Certified matchups80 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 80 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
7EH42CX-**+TDRA80UH1E090C20*16.013.47.816,600215736303
7E[C,U]48CX-**+TDRA80UH2E110C20*16.013.47.816,500215736257
7EH42CX-**+TDRA80UH1E090C20*16.013.47.816,600215736204
7EH42CX-**+TDRA80UH2E110C16*16.013.27.816,400215736296
7EH42CX-**+TDRA80UH2E110C20*16.013.47.816,500215736297
7E[C,U]48CX-**+TDRA80UH2E110C20*16.013.47.816,500215736158
7EH42CX-**+TDRA80UH2E110C16*16.013.27.816,400215736197
7EH42CX-**+TDRA80UH2E110C20*16.013.47.816,500215736198
7AH2AE42PX-16.013.27.816,300215867885
7AH2AV42PXC-16.013.47.816,300215867886
7AH2AE42PX-16.013.27.816,300215867890
7AH2AV42PXC-16.013.47.816,300215867891
7E[C,U]48CX-**+TDRA80UH2E110C16*15.513.47.816,500215736256
7E[C,U]48CX-**+TDRA80UH1E090C20*15.513.27.816,600215736259
7E[C,U]48CX-**+TDRA80UH1E110C20*15.513.47.816,600215736260
7E[C,U]48CX-**+TDRA93UH1E110C16A*15.513.27.816,600215736263
7E[C,U]48CX-**+TDRA98USMV110C20S*15.513.27.816,700215736274
7EH42BX-**+TDRA80UH2E090B12*15.513.07.816,800215736276
7EH42BX-**+TDRA80UH2E090B16*15.513.27.816,700215736277
7EH42CX-**+TDRA97US2V090C12S*15.513.07.816,700215736200
7EH42CX-**+TDRA80UH1E110C20*15.513.27.816,600215736205
7EH42CX-**+TDRA93UH1E090C16A*15.513.07.816,700215736207
7EH42BX-**+TDRA80UH1E070B12*15.513.07.816,600215736282
7EH42BX-**+TDRA80UH1E090B16*15.513.27.816,600215736283
7EH42CX-**+TDRA97US2V090C12S*15.513.07.816,700215736299
7EH42BX-**+TDRA80UH1E090B16*15.513.27.816,600215736184
7EH42BX-**+TDRA80US2V090B12*15.513.27.816,700215736191
7EH42CX-**+TDRA93UH1E110C16A*15.513.27.816,400215736208
7EH42CX-**+TDRA96UH1E090C16S*15.513.07.816,700215736210
7EH42CX-**+TDRA80US2V080C20X*15.513.27.816,600215736212
7EH42CX-**+TDRA80US2V090C20*15.513.27.816,700215736213
7EH42CX-**+TDRA80US2V090C20*15.513.27.816,700215736312
7EH42CX-**+TDRA80US2V100C20X*15.513.07.816,800215736313
7EH42CX-**+TDRA98USMV110C20S*15.513.07.816,700215736319
7EH42CX-**+TDRA98USMV110C20S*15.513.07.816,700215736220
7EH42CX-**+TDRA80UH1E110C20*15.513.27.816,600215736304
7EH42CX-**+TDRA93UH1E110C16A*15.513.27.816,400215736307
7EH42CX-**+TDRA93UH1E110C20A*15.513.07.816,800215736308
7EH42CX-**+TDRA96UH1E090C16S*15.513.07.816,700215736309
7EH42CX-**+TDRA80US2V080C20X*15.513.27.816,600215736311
7E[C,U]48CX-**+TDRA97UH2E090C16S*15.513.07.816,600215736159
7E[C,U]48CX-**+TDRA80US2V080C20X*15.513.27.816,600215736267
7E[C,U]48CX-**+TDRA80US2V090C20*15.513.27.816,700215736268
7E[C,U]48CX-**+TDRA80US2V100C20X*15.513.27.816,800215736269
7EH42BX-**+TDRA80UH2E090B12*15.513.07.816,800215736177
7EH42BX-**+TDRA80UH2E090B16*15.513.27.816,700215736178
7EH42BX-**+TDRA80UH1E070B12*15.513.07.816,600215736183
7E[C,U]48CX-**+TDRA80UH1E090C20*15.513.27.816,600215736160
7E[C,U]48CX-**+TDRA80UH1E110C20*15.513.47.816,600215736161
7E[C,U]48CX-**+TDRA93UH1E110C16A*15.513.27.816,600215736164
7E[C,U]48CX-**+TDRA80US2V090C20*15.513.27.816,700215736169
7E[C,U]48CX-**+TDRA80US2V100C20X*15.513.27.816,800215736170
7E[C,U]48CX-**+TDRA98USMV110C20S*15.513.27.816,700215736175
7EH42CX-**+TDRA97UH2E090C16S*15.513.07.816,800215736199
7EH42CX-**+TDRA97UH2E090C16S*15.513.07.816,800215736298
7E[C,U]48CX-**+TDRA97UH2E090C16S*15.513.07.816,600215736258
7EH42BX-**+TDRA80US2V090B12*15.513.27.816,700215736290
7EH42CX-**+TDRA93UH1E110C20A*15.513.07.816,800215736209
7EH42CX-**+TDRA80US2V100C20X*15.513.07.816,800215736214
7EH42CX-**+TDRA93UH1E090C16A*15.513.07.816,700215736306
Yearly running cost in 10 large cities$1,056-$2,763

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the AIREASE A7HP14F36P-**A?
The AIREASE A7HP14F36P-**A is rated at up to 16.0 SEER2 and 13.4 EER2 for cooling and up to 8.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 80 certified matchups SEER2 ranges from 15.2-16.0.
Is the AIREASE A7HP14F36P-**A good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 3-ton model.
How much does the AIREASE A7HP14F36P-**A cost to run per year?
At its rated efficiency it costs about $1,056-$2,763 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,294 in Phoenix and $2,302 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the AIREASE A7HP14F36P-**A?
ENERGY STAR lists 80 certified combinations for this outdoor unit. The highest-rated ones use 7EH42CX-**+TDR, 7E[C,U]48CX-**+TDR, 7AH2AE42PX.
What refrigerant does the AIREASE A7HP14F36P-**A use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,279/yrYou save $557/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump AIREASE A7HP14F36P-**A
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,279
Current system, per year
$1,837
You save per year
$557
Payback
24.2 years
Net after 10 years
-$7,926

Cooling $792Heating $487Electricity used: 7,995 kWhSaved vs. a minimum-efficiency heat pump: $127

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 3 ton models

See all 302 3 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of June 29, 2026. How we use the data.