HVAC Rated

3-ton central heat pump · LEGACY 15 SEER2 HP

Bryant 235SAN036**AA

Below average cooling and heating efficiency for a 3-ton central heat pump, but not rated for cold climates.

Ranks #240 of 302 3 ton central heat pumps for cooling efficiency, and costs about $1,154 a year to run in a mixed climate like Atlanta.

SEER2
16.0 Cooling efficiency over a season
Below average · beats 26%
HSPF2
8.0 Heating efficiency over a season
Below average · beats 12%
EER2
13.0 Cooling efficiency on a 95°F day
Very good · beats 89%
Heat at 5°F
18,100 BTU/h48% of its 47°F output
Very good · beats 80%

A good fit if…

  • You want a choice of indoor units - 33 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • Cooling cost matters most - its SEER2 is below average for central heat pumps.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.
  • Comfort and noise matter - a single-stage compressor runs only full-on or off.

Calculate my running cost

Details

Specifications3 ton, R-454B
General
BrandBryant
Outdoor unit model235SAN036**AA
SeriesLEGACY 15 SEER2 HP
TypeCentral heat pump
Nominal size3 ton
CompressorVariable-speed units run longer at low powerSingle stage
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceJanuary 1, 2024
Last certifiedJune 16, 2026
Cooling
SEER2Seasonal efficiency, higher is better16.0 (range 15.2-16.0)
EER2Efficiency at 95°F outdoors11.7-13.0
Cooling capacity33,800-36,800 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8-8.0
Capacity at 47°F33,200-36,400 BTU/h
Capacity at 17°F21,000-22,800 BTU/h
Capacity at 5°F16,100-18,100 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.00-2.22
ENERGY STAR cold climateNo
Heating output as it gets colder48% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with FEVA0048**+NAVA54801CK at the standard test temperatures, in BTU/h:

Certified matchups33 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
FEVA0048**+NAVA54801CK-16.013.08.017,400217051634
FT5AN(B,X)C48L-15.512.57.816,700214179926
FG5ANXC48L-15.512.57.816,700214179927
PF5TNXC48L-15.512.57.816,700214179928
PF5MN*C48L-15.513.07.817,400214180172
FJ5AN*C48L-15.513.07.817,400214180171
FEVB0048**+NAVA54801CK-15.512.57.817,400214277593
FMA5X36**AL-15.512.57.817,000214424286
F55AA*C48L-15.513.07.817,400216463998
FM(C,U)5S36**AL-15.212.08.017,300218452403
CAA**4821AM83*SB48060M17***15.212.07.817,600214141628
CAA**4821AM935SB66100M21***15.212.07.817,600214142631
CAA**4821AM88*TB60110C21***15.212.07.817,500214141832
CAA**4821AM82*TB60090V21***15.212.07.817,500214141941
CAA**4821AM926TC66100V21***15.211.77.817,500214142857
CAA**4821AM8(0,1)*SB60090M21***15.212.07.817,500214141336
CAA**4321AM912SE60100M21***15.212.07.817,900214140509
CAA**4821AM8(0,1)*SB60110M21***15.212.07.817,600214141366
CAA**4821AM912SE60100M21***15.212.07.817,600214142255
CAA**4821AM82*SB60090V21***15.212.07.817,500214141450
CVAMA4421XMA83*SA36040E17***15.212.07.818,100214143044
CAA**4321AM83*CA60100C21***15.212.07.817,600214139781
CAA**3721AM83*CA48060C17***15.212.07.817,100214138082
CAA**4321AM83*CA48060C17***15.212.07.817,000214139754
CAA**3721AM8(0,1)*SB60090M21***15.212.07.817,900214138226
CAA**4821AM83*SB60080M21***15.212.07.817,300214141660
CAA**4321AM8(0,1)*SB60090M21***15.212.07.817,900214139942
CAA**4321AM8(0,1)*SB60110M21***15.212.07.818,000214139972
CVAVA4224XMA83*SB60100M21***15.212.07.818,100214144589
FJ5AN*C42L-15.212.57.816,100214179887
PF5MN*C42L-15.212.57.816,100214179888
FM(C,U)5Z36**AL-15.212.57.817,200215829098
F55AA*C42L-15.212.57.816,100216463971
Same unit, other model numbers1

These model numbers have exactly the same certified ratings and matchups as the Bryant 235SAN036**AA: the same equipment under another brand, or a variant code for voltage, colour or market. Everything on this page applies to them.

Yearly running cost in 10 large cities$1,028-$2,761

At each state's average electricity price and the city's typical heating and cooling hours.

Questions6
What is the SEER2 rating of the Bryant 235SAN036**AA?
The Bryant 235SAN036**AA is rated at up to 16.0 SEER2 and 13.0 EER2 for cooling and up to 8.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 33 certified matchups SEER2 ranges from 15.2-16.0.
Is the Bryant 235SAN036**AA good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 3-ton model.
How much does the Bryant 235SAN036**AA cost to run per year?
At its rated efficiency it costs about $1,028-$2,761 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,269 in Phoenix and $2,308 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Is the Bryant 235SAN036**AA the same as the Bryant 246SAN036**AA?
Yes, as far as the certified ratings go. ENERGY STAR lists both model numbers with identical efficiency, capacity and matchups, which means the same outdoor unit sold under a different brand or with a minor variant code (voltage, colour or region). The full list is on this page.
Which indoor units work with the Bryant 235SAN036**AA?
ENERGY STAR lists 33 certified combinations for this outdoor unit. The highest-rated ones use FEVA0048**+NAVA54801CK, FT5AN(B,X)C48L, FG5ANXC48L.
What refrigerant does the Bryant 235SAN036**AA use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,260/yrYou save $545/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Bryant 235SAN036**AA
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,260
Current system, per year
$1,805
You save per year
$545
Payback
23.9 years
Net after 10 years
-$7,553

Cooling $770Heating $490Electricity used: 7,875 kWhSaved vs. a minimum-efficiency heat pump: $124

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 3 ton models

See all 302 3 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of June 16, 2026. How we use the data.