3-ton central heat pump · LEGACY 15 SEER2 HP
Bryant 235SAN036**AA
Below average cooling and heating efficiency for a 3-ton central heat pump, but not rated for cold climates.
Ranks #240 of 302 3 ton central heat pumps for cooling efficiency, and costs about $1,154 a year to run in a mixed climate like Atlanta.
- SEER2
- 16.0 Cooling efficiency over a seasonBelow average · beats 26%
- HSPF2
- 8.0 Heating efficiency over a seasonBelow average · beats 12%
- EER2
- 13.0 Cooling efficiency on a 95°F dayVery good · beats 89%
- Heat at 5°F
- 18,100 BTU/h48% of its 47°F outputVery good · beats 80%
A good fit if…
- You want a choice of indoor units - 33 certified pairings.
Think twice if…
- You often see nights below 0°F - it is not cold-climate certified.
- Cooling cost matters most - its SEER2 is below average for central heat pumps.
- You mainly need heat - its HSPF2 is below average for central heat pumps.
- Comfort and noise matter - a single-stage compressor runs only full-on or off.
Details
Specifications
| General | |
|---|---|
| Brand | Bryant |
| Outdoor unit model | 235SAN036**AA |
| Series | LEGACY 15 SEER2 HP |
| Type | Central heat pump |
| Nominal size | 3 ton |
| CompressorVariable-speed units run longer at low power | Single stage |
| Refrigerant | R-454B |
| Connected (smart) capable | No |
| On the market since | January 1, 2024 |
| Last certified | June 16, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 16.0 (range 15.2-16.0) |
| EER2Efficiency at 95°F outdoors | 11.7-13.0 |
| Cooling capacity | 33,800-36,800 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 7.8-8.0 |
| Capacity at 47°F | 33,200-36,400 BTU/h |
| Capacity at 17°F | 21,000-22,800 BTU/h |
| Capacity at 5°F | 16,100-18,100 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 2.00-2.22 |
| ENERGY STAR cold climate | No |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with FEVA0048**+NAVA54801CK at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit and furnace. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | Furnace | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|---|
| FEVA0048**+NAVA54801CK | - | 16.0 | 13.0 | 8.0 | 17,400 | 217051634 |
| FT5AN(B,X)C48L | - | 15.5 | 12.5 | 7.8 | 16,700 | 214179926 |
| FG5ANXC48L | - | 15.5 | 12.5 | 7.8 | 16,700 | 214179927 |
| PF5TNXC48L | - | 15.5 | 12.5 | 7.8 | 16,700 | 214179928 |
| PF5MN*C48L | - | 15.5 | 13.0 | 7.8 | 17,400 | 214180172 |
| FJ5AN*C48L | - | 15.5 | 13.0 | 7.8 | 17,400 | 214180171 |
| FEVB0048**+NAVA54801CK | - | 15.5 | 12.5 | 7.8 | 17,400 | 214277593 |
| FMA5X36**AL | - | 15.5 | 12.5 | 7.8 | 17,000 | 214424286 |
| F55AA*C48L | - | 15.5 | 13.0 | 7.8 | 17,400 | 216463998 |
| FM(C,U)5S36**AL | - | 15.2 | 12.0 | 8.0 | 17,300 | 218452403 |
| CAA**4821AM | 83*SB48060M17*** | 15.2 | 12.0 | 7.8 | 17,600 | 214141628 |
| CAA**4821AM | 935SB66100M21*** | 15.2 | 12.0 | 7.8 | 17,600 | 214142631 |
| CAA**4821AM | 88*TB60110C21*** | 15.2 | 12.0 | 7.8 | 17,500 | 214141832 |
| CAA**4821AM | 82*TB60090V21*** | 15.2 | 12.0 | 7.8 | 17,500 | 214141941 |
| CAA**4821AM | 926TC66100V21*** | 15.2 | 11.7 | 7.8 | 17,500 | 214142857 |
| CAA**4821AM | 8(0,1)*SB60090M21*** | 15.2 | 12.0 | 7.8 | 17,500 | 214141336 |
| CAA**4321AM | 912SE60100M21*** | 15.2 | 12.0 | 7.8 | 17,900 | 214140509 |
| CAA**4821AM | 8(0,1)*SB60110M21*** | 15.2 | 12.0 | 7.8 | 17,600 | 214141366 |
| CAA**4821AM | 912SE60100M21*** | 15.2 | 12.0 | 7.8 | 17,600 | 214142255 |
| CAA**4821AM | 82*SB60090V21*** | 15.2 | 12.0 | 7.8 | 17,500 | 214141450 |
| CVAMA4421XMA | 83*SA36040E17*** | 15.2 | 12.0 | 7.8 | 18,100 | 214143044 |
| CAA**4321AM | 83*CA60100C21*** | 15.2 | 12.0 | 7.8 | 17,600 | 214139781 |
| CAA**3721AM | 83*CA48060C17*** | 15.2 | 12.0 | 7.8 | 17,100 | 214138082 |
| CAA**4321AM | 83*CA48060C17*** | 15.2 | 12.0 | 7.8 | 17,000 | 214139754 |
| CAA**3721AM | 8(0,1)*SB60090M21*** | 15.2 | 12.0 | 7.8 | 17,900 | 214138226 |
| CAA**4821AM | 83*SB60080M21*** | 15.2 | 12.0 | 7.8 | 17,300 | 214141660 |
| CAA**4321AM | 8(0,1)*SB60090M21*** | 15.2 | 12.0 | 7.8 | 17,900 | 214139942 |
| CAA**4321AM | 8(0,1)*SB60110M21*** | 15.2 | 12.0 | 7.8 | 18,000 | 214139972 |
| CVAVA4224XMA | 83*SB60100M21*** | 15.2 | 12.0 | 7.8 | 18,100 | 214144589 |
| FJ5AN*C42L | - | 15.2 | 12.5 | 7.8 | 16,100 | 214179887 |
| PF5MN*C42L | - | 15.2 | 12.5 | 7.8 | 16,100 | 214179888 |
| FM(C,U)5Z36**AL | - | 15.2 | 12.5 | 7.8 | 17,200 | 215829098 |
| F55AA*C42L | - | 15.2 | 12.5 | 7.8 | 16,100 | 216463971 |
Same unit, other model numbers
These model numbers have exactly the same certified ratings and matchups as the Bryant 235SAN036**AA: the same equipment under another brand, or a variant code for voltage, colour or market. Everything on this page applies to them.
- Bryant 246SAN036**AA
Yearly running cost in 10 large cities
- Phoenix, AZ$1,269/yr
- Miami, FL$1,028/yr
- Houston, TX$1,138/yr
- Atlanta, GA$1,154/yr
- Los Angeles, CA$1,123/yr
- New York, NY$2,761/yr
- Chicago, IL$2,242/yr
- Denver, CO$1,864/yr
- Seattle, WA$1,146/yr
- Minneapolis, MN$2,308/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the Bryant 235SAN036**AA?
- The Bryant 235SAN036**AA is rated at up to 16.0 SEER2 and 13.0 EER2 for cooling and up to 8.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 33 certified matchups SEER2 ranges from 15.2-16.0.
- Is the Bryant 235SAN036**AA good for cold climates?
- It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 3-ton model.
- How much does the Bryant 235SAN036**AA cost to run per year?
- At its rated efficiency it costs about $1,028-$2,761 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,269 in Phoenix and $2,308 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Is the Bryant 235SAN036**AA the same as the Bryant 246SAN036**AA?
- Yes, as far as the certified ratings go. ENERGY STAR lists both model numbers with identical efficiency, capacity and matchups, which means the same outdoor unit sold under a different brand or with a minor variant code (voltage, colour or region). The full list is on this page.
- Which indoor units work with the Bryant 235SAN036**AA?
- ENERGY STAR lists 33 certified combinations for this outdoor unit. The highest-rated ones use FEVA0048**+NAVA54801CK, FT5AN(B,X)C48L, FG5ANXC48L.
- What refrigerant does the Bryant 235SAN036**AA use?
- It uses R-454B.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 3 ton models
- AIREASE A7HP14F36P-**A16.0 SEER2 · 8.0 HSPF2
- York YH536E2S1116.0 SEER2 · 8.1 HSPF2
- York YH2F36TB21 · cold climate16.0 SEER2 · 8.1 HSPF2
- Carrier 27SCA536A**3016.0 SEER2 · 8.0 HSPF2
- Trane N5HP5036A116.0 SEER2 · 8.1 HSPF2
- Ducane 7HP14F36P-**A16.0 SEER2 · 8.0 HSPF2
- Trane 5HPL5036A1000AA · cold climate16.0 SEER2 · 8.1 HSPF2
- Frigidaire FSH4BF5M2SX36K16.0 SEER2 · 8.0 HSPF2
See all 302 3 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of June 16, 2026. How we use the data.