HVAC Rated

4-ton central heat pump · A7HP19V Series

AIREASE A7HP19V60P-**A

Very good cooling efficiency and average heating efficiency for a 4-ton central heat pump, but not rated for cold climates.

Ranks #73 of 319 4 ton central heat pumps for cooling efficiency, and costs about $1,374 a year to run in a mixed climate like Atlanta.

SEER2
18.5 Cooling efficiency over a season
Very good · beats 77%
HSPF2
9.0 Heating efficiency over a season
Average · beats 54%
EER2
11.5 Cooling efficiency on a 95°F day
Below average · beats 31%
Heat at 5°F
29,600 BTU/h50% of its 47°F output
Average · beats 51%

A good fit if…

  • You want low cooling bills - its SEER2 beats 77% of central heat pumps.
  • You want steady temperatures and quiet running - the compressor varies its speed.
  • You want a choice of indoor units - 128 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.

Calculate my running cost

Details

Specifications4 ton, R-454B
General
BrandAIREASE
Also sold asArmstrong Air
Outdoor unit modelA7HP19V60P-**A
SeriesA7HP19V Series
TypeCentral heat pump
Nominal size4 ton
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceMarch 28, 2025
Last certifiedSeptember 22, 2026
Cooling
SEER2Seasonal efficiency, higher is better18.5 (range 16.5-18.5)
EER2Efficiency at 95°F outdoors11.0-11.7
Cooling capacity46,500-48,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8-9.0
Capacity at 47°F45,000-48,000 BTU/h
Capacity at 17°F27,600-31,200 BTU/h
Capacity at 5°F21,800-29,600 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.80-2.06
ENERGY STAR cold climateNo
Heating output as it gets colder50% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with 7E[C,U]50/60CX-**+TDR at the standard test temperatures, in BTU/h:

Certified matchups128 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 128 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
7E[C,U]50/60CX-**+TDRA80US2V080C20X*18.511.58.223,600217203210
7E[C,U]50/60CX-**+TDRA80US2V100C20X*18.511.28.223,600217203212
7E[C,U]50/60CX-**+TDRA97US2V080C16X*18.511.28.223,800217203215
7E[C,U]50/60CX-**+TDRA80US2V080C20X*18.511.58.223,600217202910
7E[C,U]50/60CX-**+TDRA80US2V100C20X*18.511.28.223,600217202912
7E[C,U]50/60CX-**+TDRA97US2V080C16X*18.511.28.223,800217202915
7E[C,U]50/60CX-**+TDRA97US2V110C16S*18.511.28.223,800217727973
7E[C,U]50/60CX-**+TDRA97US2V110C16S*18.511.28.223,800217727989
7E[C,U]48CX-**+TDRA80US2V080C20X*18.511.57.822,200217203235
7E[C,U]48CX-**+TDRA80US2V080C20X*18.511.57.822,200217202935
7ED50/60CX-**+TDRA80DS2V110C20*18.511.57.829,400217455970
7ED50/60CX-**+TDRA80DS2V110C20*18.511.57.829,400217456120
7AH2AV48PXC-18.211.28.423,200217203197
7AH2AV48PXC-18.211.28.423,200217202897
7E[C,U]50/60CX-**+TDRA80UH2E110C16*18.011.58.223,400217203201
7E[C,U]50/60CX-**+TDRA80UH1E110C20*18.011.28.223,600217203204
7E[C,U]50/60CX-**+TDRA93UH1E090C16A*18.011.28.223,400217203205
7E[C,U]50/60CX-**+TDRA80US2V090C20*18.011.28.223,600217203211
7E[C,U]50/60CX-**+TDRA80US2V110C20*18.011.28.223,600217203213
7E[C,U]50/60CX-**+TDRA80US2V110C20L*18.011.28.223,600217203214
7E[C,U]50/60CX-**+TDRA97US2V080C20X*18.011.08.224,000217203216
7E[C,U]50/60CX-**+TDRA98USMV090C16S*18.011.28.223,800217203217
7E[C,U]50/60CX-**+TDRA98USMV090C20S*18.011.28.223,800217203218
7E[C,U]50/60CX-**+TDRA98USMV110C20S*18.011.28.223,800217203219
7E[C,U]50/60CX-**+TDRA97US2V090C16S*18.011.08.223,800217203220
7E[C,U]50/60CX-**+TDRA97US2V090C20S*18.011.28.223,800217203221
7AH2AE48PX--18.011.58.223,400217203027
7E[C,U]50/60CX-**+TDRA80UH1E110C20*18.011.28.223,600217202904
7E[C,U]50/60CX-**+TDRA80UH2E110C16*18.011.58.223,400217202901
7E[C,U]50/60CX-**+TDRA93UH1E090C16A*18.011.28.223,400217202905
7E[C,U]50/60CX-**+TDRA96UH1E090C16S*18.011.28.223,400217202908
7E[C,U]50/60CX-**+TDRA80US2V090C20*18.011.28.223,600217202911
7E[C,U]50/60CX-**+TDRA80US2V110C20*18.011.28.223,600217202913
7E[C,U]50/60CX-**+TDRA80US2V110C20L*18.011.28.223,600217202914
7E[C,U]50/60CX-**+TDRA97US2V080C20X*18.011.08.224,000217202916
7E[C,U]50/60CX-**+TDRA98USMV090C16S*18.011.28.223,800217202917
7E[C,U]50/60CX-**+TDRA98USMV090C20S*18.011.28.223,800217202918
7E[C,U]50/60CX-**+TDRA98USMV110C20S*18.011.28.223,800217202919
7E[C,U]50/60CX-**+TDRA97US2V090C16S*18.011.08.223,800217202920
7E[C,U]50/60CX-**+TDRA97US2V090C20S*18.011.28.223,800217202921
7E[C,U]50/60CX-**+TDRA96UH1E090C16S*18.011.28.223,400217203208
7AH2AE48PX--18.011.58.223,400217203327
7E[C,U]50/60CX-**+TDRA80UH1E090B16*18.011.58.223,400217455929
7E[C,U]50/60CX-**+TDRA80UH1E090B16*18.011.58.223,400217456079
7E[C,U]50/60CX-**+TDRA97US2V110C20S*18.011.28.223,800217727974
7E[C,U]50/60CX-**+TDRA97US2V110C20S*18.011.28.223,800217727990
7E[C,U]50/60CX-**+TDRA97UH1E080C16*18.011.28.224,400218788137
7E[C,U]50/60CX-**+TDRA97UH1E080C16*18.011.28.224,400218788132
7ED50/60CX-**+TDRA80DF1E110C20*18.011.78.028,800217455966
7ED50/60CX-**+TDRA93DF1E090C16A*18.011.28.029,400217455967
7ED50/60CX-**+TDRA80DF1E110C20*18.011.78.028,800217456116
7ED50/60CX-**+TDRA93DF1E090C16A*18.011.28.029,400217456117
7AH1AE48PX--18.011.77.823,400217203329
7E[C,U]48BX-**+TDRA80UH2E090B16*18.011.57.822,200217203262
7E[C,U]48BX-**+TDRA80UH1E090B16*18.011.77.822,000217203268
7E[C,U]48CX-**+TDRA80UH1E110C20*18.011.57.822,200217203229
7E[C,U]48CX-**+TDRA93UH1E090C16A*18.011.57.822,000217203230
7E[C,U]48CX-**+TDRA93UH1E110C16A*18.011.57.822,000217203231
7E[C,U]48CX-**+TDRA96UH1E090C16S*18.011.57.822,000217203233
7E[C,U]48CX-**+TDRA97UH2E090C16S*18.011.57.822,000217203248
Yearly running cost in 10 large cities$1,220-$3,291

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the AIREASE A7HP19V60P-**A?
The AIREASE A7HP19V60P-**A is rated at up to 18.5 SEER2 and 11.5 EER2 for cooling and up to 9.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 128 certified matchups SEER2 ranges from 16.5-18.5.
Is the AIREASE A7HP19V60P-**A good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 4-ton model.
How much does the AIREASE A7HP19V60P-**A cost to run per year?
At its rated efficiency it costs about $1,220-$3,291 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,508 in Phoenix and $2,753 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the AIREASE A7HP19V60P-**A?
ENERGY STAR lists 128 certified combinations for this outdoor unit. The highest-rated ones use 7E[C,U]50/60CX-**+TDR, 7E[C,U]48CX-**+TDR, 7ED50/60CX-**+TDR.
What refrigerant does the AIREASE A7HP19V60P-**A use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,498/yrYou save $960/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump AIREASE A7HP19V60P-**A
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,498
Current system, per year
$2,459
You save per year
$960
Payback
18.7 years
Net after 10 years
-$8,395

Cooling $913Heating $585Electricity used: 9,364 kWhSaved vs. a minimum-efficiency heat pump: $385

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 4 ton models

See all 319 4 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of September 22, 2026. How we use the data.