4-ton central heat pump · Elite EL19KPV SERIES
Lennox EL19KPV-048-230A
Very good cooling efficiency and average heating efficiency for a 4-ton central heat pump, but not rated for cold climates.
Ranks #75 of 319 4 ton central heat pumps for cooling efficiency, and costs about $1,369 a year to run in a mixed climate like Atlanta.
- SEER2
- 18.5 Cooling efficiency over a seasonVery good · beats 77%
- HSPF2
- 9.0 Heating efficiency over a seasonAverage · beats 54%
- EER2
- 11.2 Cooling efficiency on a 95°F dayBelow average · beats 28%
- Heat at 5°F
- 32,800 BTU/h63% of its 47°F outputVery good · beats 83%
A good fit if…
- You want low cooling bills - its SEER2 beats 77% of central heat pumps.
- You want steady temperatures and quiet running - the compressor varies its speed.
- You want a choice of indoor units - 218 certified pairings.
Think twice if…
- You often see nights below 0°F - it is not cold-climate certified.
Details
Specifications
| General | |
|---|---|
| Brand | Lennox |
| Outdoor unit model | EL19KPV-048-230A |
| Series | Elite EL19KPV SERIES |
| Type | Central heat pump |
| Nominal size | 4 ton |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-454B |
| Connected (smart) capable | No |
| On the market since | March 26, 2025 |
| Last certified | September 22, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 18.5 (range 16.0-18.5) |
| EER2Efficiency at 95°F outdoors | 11.0-11.7 |
| Cooling capacity | 46,000-48,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 7.8-9.0 |
| Capacity at 47°F | 45,000-52,000 BTU/h |
| Capacity at 17°F | 27,600-33,200 BTU/h |
| Capacity at 5°F | 21,000-32,800 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.80-2.26 |
| ENERGY STAR cold climate | No |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with CK40DT-60D-**+TDR at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 218 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | Furnace | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|---|
| CK40DT-60D-**+TDR | EL297DF090XV60C* | 18.5 | 11.2 | 8.5 | 30,200 | 217446828 |
| CK40DT-60D-**+TDR | EL297DF110XV60C* | 18.5 | 11.2 | 8.5 | 30,200 | 217446830 |
| CK40DT-60D-**+TDR | SL280DF090V60C* | 18.5 | 11.5 | 8.5 | 30,000 | 217446831 |
| CK40DT-60D-**+TDR | SL280DF110V60C* | 18.5 | 11.5 | 8.5 | 30,000 | 217446832 |
| CK40DT-60D-**+TDR | SLP99DF090XV60C* | 18.5 | 11.2 | 8.5 | 30,200 | 217446833 |
| CK40DT-60D-**+TDR | SLP99DF110XV60C* | 18.5 | 11.0 | 8.5 | 30,400 | 217446834 |
| CK40[C,U]T-49C-**+TDR | SLP99UH090XV48C* | 18.5 | 11.0 | 8.5 | 23,800 | 217577826 |
| CK40[C,U]T-49C-**+TDR | EL297UH110XV48C* | 18.5 | 11.0 | 8.5 | 23,600 | 217577833 |
| CK40[C,U]T-49C-**+TDR | EL297UH090XV48C* | 18.5 | 11.0 | 8.5 | 23,800 | 217577830 |
| CK40[C,U]T-60C-**+TDR | SLP99UH090XV48C* | 18.5 | 11.2 | 8.5 | 23,800 | 217577843 |
| CK40[C,U]T-60C-**+TDR | SLP99UH110XV60C* | 18.5 | 11.2 | 8.5 | 23,600 | 217577845 |
| CK40[C,U]T-60C-**+TDR | EL297UH110XV48C* | 18.5 | 11.2 | 8.5 | 23,600 | 217577850 |
| CK40[C,U]T-60C-**+TDR | EL297UH090XV48C* | 18.5 | 11.2 | 8.5 | 23,800 | 217577847 |
| CK40[C,U]T-60C-**+TDR | EL297UH110XV60C* | 18.5 | 11.2 | 8.5 | 23,600 | 217577851 |
| CK40[C,U]T-49C-**+TDR | SL280UH090V60C* | 18.5 | 11.2 | 8.5 | 23,600 | 217577865 |
| CK40[C,U]T-49C-**+TDR | SL280UH090XV60C* | 18.5 | 11.2 | 8.5 | 23,600 | 217577866 |
| CK40[C,U]T-60C-**+TDR | SL280UH080NV60C* | 18.5 | 11.2 | 8.5 | 23,600 | 217577882 |
| CK40[C,U]T-60C-**+TDR | SL280UH090V60C* | 18.5 | 11.2 | 8.5 | 23,600 | 217577883 |
| CK40[C,U]T-60C-**+TDR | SL280UH090XV60C* | 18.5 | 11.2 | 8.5 | 23,600 | 217577884 |
| CK40[C,U]T-50/60C-**+TDR | SL280UH080NV60C* | 18.5 | 11.5 | 8.2 | 23,600 | 217194450 |
| CK40[C,U]T-50/60C-**+TDR | SL280UH100NV60C* | 18.5 | 11.2 | 8.2 | 23,600 | 217194453 |
| CK40[C,U]T-50/60C-**+TDR | SL297UH080NV48C* | 18.5 | 11.2 | 8.2 | 23,800 | 217194456 |
| CK40[C,U]T-50/60C-**+TDR | EL297UH110XV48C* | 18.5 | 11.2 | 8.2 | 23,800 | 217194464 |
| CK40[C,U]T-48C-**+TDR | SL280UH080NV60C* | 18.5 | 11.5 | 7.8 | 22,200 | 217194490 |
| CK40DT-50/60C-**+TDR | SL280DF110V60C* | 18.5 | 11.5 | 7.8 | 29,400 | 217446827 |
| CK40HT-42B-**+TDR | ML180UH070V48B* | 18.5 | 11.5 | 7.8 | 26,600 | 217446771 |
| CBK48MVT-048-230- | - | 18.2 | 11.2 | 8.4 | 23,200 | 217194428 |
| CBK48MVT-060-230- | - | 18.0 | 11.2 | 9.0 | 32,600 | 217194429 |
| CK40[C,U]T-49C-**+TDR | EL280UH110E48C* | 18.0 | 11.2 | 9.0 | 23,400 | 217577854 |
| CK40[C,U]T-49C-**+TDR | SLP99UH110XV60C* | 18.0 | 11.2 | 8.5 | 23,600 | 217577828 |
| CK40[C,U]T-49C-**+TDR | EL297UH090XE48C* | 18.0 | 11.2 | 8.5 | 23,400 | 217577829 |
| CK40[C,U]T-49C-**+TDR | EL297UH090XV60C* | 18.0 | 11.0 | 8.5 | 23,800 | 217577831 |
| CK40[C,U]T-49C-**+TDR | SLP99UH090XV60C* | 18.0 | 11.0 | 8.5 | 23,800 | 217577827 |
| CK40[C,U]T-49C-**+TDR | EL297UH110XV60C* | 18.0 | 11.2 | 8.5 | 23,600 | 217577834 |
| CK40[C,U]T-60C-**+TDR | SL297UH080NV60C* | 18.0 | 11.0 | 8.5 | 23,800 | 217577842 |
| CK40[C,U]T-60C-**+TDR | SLP99UH090XV60C* | 18.0 | 11.2 | 8.5 | 23,800 | 217577844 |
| CK40[C,U]T-60C-**+TDR | EL297UH090XE48C* | 18.0 | 11.2 | 8.5 | 23,000 | 217577846 |
| CK40[C,U]T-60C-**+TDR | EL297UH090XV60C* | 18.0 | 11.2 | 8.5 | 23,800 | 217577848 |
| CK40[C,U]T-49C-**+TDR | ML193UH110XE48C* | 18.0 | 11.2 | 8.5 | 23,400 | 217577862 |
| CK40[C,U]T-49C-**+TDR | ML180UH110V60C* | 18.0 | 11.2 | 8.5 | 23,600 | 217577859 |
| CK40[C,U]T-49C-**+TDR | SL280UH080NV60C* | 18.0 | 11.2 | 8.5 | 23,600 | 217577864 |
| CK40[C,U]T-49C-**+TDR | SL280UH100NV60C* | 18.0 | 11.2 | 8.5 | 23,600 | 217577867 |
| CK40[C,U]T-49C-**+TDR | SL280UH110V60C* | 18.0 | 11.2 | 8.5 | 23,600 | 217577868 |
| CK40[C,U]T-49C-**+TDR | SL280UH110XV60C* | 18.0 | 11.2 | 8.5 | 23,600 | 217577869 |
| CK40[C,U]T-60C-**+TDR | EL280UH110E48C* | 18.0 | 11.5 | 8.5 | 23,400 | 217577872 |
| CK40[C,U]T-60C-**+TDR | ML180UH110V60C* | 18.0 | 11.5 | 8.5 | 23,600 | 217577877 |
| CK40[C,U]T-60C-**+TDR | SL280UH110V60C* | 18.0 | 11.2 | 8.5 | 23,600 | 217577886 |
| CK40[C,U]T-60C-**+TDR | SL280UH110XV60C* | 18.0 | 11.2 | 8.5 | 23,600 | 217577887 |
| CK40[C,U]T-60C-**+TDR | ML193UH110XE48C* | 18.0 | 11.2 | 8.5 | 23,000 | 217577880 |
| CK40[C,U]T-60C-**+TDR | ML180UH070V48B* | 18.0 | 11.2 | 8.5 | 23,600 | 217577888 |
| CK40[C,U]T-60C-**+TDR | SL280UH100NV60C* | 18.0 | 11.2 | 8.5 | 23,600 | 217577885 |
| CBK47UHET-048-230- | - | 18.0 | 11.5 | 8.2 | 23,400 | 217194651 |
| CK40[C,U]T-50/60C-**+TDR | EL280UH110E48C* | 18.0 | 11.5 | 8.2 | 23,400 | 217194435 |
| CK40[C,U]T-50/60C-**+TDR | ML180UH110E60C* | 18.0 | 11.2 | 8.2 | 23,600 | 217194439 |
| CK40[C,U]T-50/60C-**+TDR | ML180UH110XE60C* | 18.0 | 11.2 | 8.2 | 23,600 | 217194441 |
| CK40[C,U]T-50/60C-**+TDR | ML193UH090XE48C* | 18.0 | 11.2 | 8.2 | 23,400 | 217194442 |
| CK40[C,U]T-50/60C-**+TDR | ML196UH090XE48C* | 18.0 | 11.2 | 8.2 | 23,400 | 217194445 |
| CK40[C,U]T-50/60C-**+TDR | SL280UH090V60C* | 18.0 | 11.2 | 8.2 | 23,600 | 217194451 |
| CK40[C,U]T-50/60C-**+TDR | SL280UH090XV60C* | 18.0 | 11.2 | 8.2 | 23,600 | 217194452 |
| CK40[C,U]T-50/60C-**+TDR | SL280UH110V60C* | 18.0 | 11.2 | 8.2 | 23,600 | 217194454 |
Yearly running cost in 10 large cities
- Phoenix, AZ$1,496/yr
- Miami, FL$1,207/yr
- Houston, TX$1,341/yr
- Atlanta, GA$1,369/yr
- Los Angeles, CA$1,334/yr
- New York, NY$3,285/yr
- Chicago, IL$2,670/yr
- Denver, CO$2,222/yr
- Seattle, WA$1,367/yr
- Minneapolis, MN$2,750/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the Lennox EL19KPV-048-230A?
- The Lennox EL19KPV-048-230A is rated at up to 18.5 SEER2 and 11.2 EER2 for cooling and up to 9.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 218 certified matchups SEER2 ranges from 16.0-18.5.
- Is the Lennox EL19KPV-048-230A good for cold climates?
- It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 4-ton model.
- How much does the Lennox EL19KPV-048-230A cost to run per year?
- At its rated efficiency it costs about $1,207-$3,285 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,496 in Phoenix and $2,750 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the Lennox EL19KPV-048-230A?
- ENERGY STAR lists 218 certified combinations for this outdoor unit. The highest-rated ones use CK40DT-60D-**+TDR, CK40[C,U]T-49C-**+TDR, CK40[C,U]T-60C-**+TDR.
- What refrigerant does the Lennox EL19KPV-048-230A use?
- It uses R-454B.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 4 ton models
- GE NS19H60MA5-**A18.5 SEER2 · 9.0 HSPF2
- AC Pro BH719M60P-**A18.5 SEER2 · 8.5 HSPF2
- AIREASE A7HP19V60P-**A18.5 SEER2 · 9.0 HSPF2
- Armstrong Air A7SCP18V60P-**A · cold climate18.3 SEER2 · 9.6 HSPF2
- OUTES OTD-H60DMR3-C01/SE180 · cold climate18.5 SEER2 · 9.2 HSPF2
- 1HVAC ACIQ-60-HP32 · cold climate18.2 SEER2 · 10.5 HSPF2
- Emeric ETD-H48DMR3 · cold climate18.5 SEER2 · 9.2 HSPF2
- TOSOT TU60-32WEDU · cold climate18.2 SEER2 · 10.5 HSPF2
See all 319 4 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of September 22, 2026. How we use the data.