HVAC Rated

4-ton central heat pump · NS19H Series

GE NS19H60MA5-**A

Very good cooling efficiency and average heating efficiency for a 4-ton central heat pump, but not rated for cold climates.

Ranks #74 of 319 4 ton central heat pumps for cooling efficiency, and costs about $1,369 a year to run in a mixed climate like Atlanta.

SEER2
18.5 Cooling efficiency over a season
Very good · beats 77%
HSPF2
9.0 Heating efficiency over a season
Average · beats 54%
EER2
11.0 Cooling efficiency on a 95°F day
Below average · beats 23%
Heat at 5°F
32,600 BTU/h63% of its 47°F output
Very good · beats 83%

A good fit if…

  • You want low cooling bills - its SEER2 beats 77% of central heat pumps.
  • You want steady temperatures and quiet running - the compressor varies its speed.
  • You want a choice of indoor units - 66 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.

Calculate my running cost

Details

Specifications4 ton, R-454B
General
BrandGE
Outdoor unit modelNS19H60MA5-**A
SeriesNS19H Series
TypeCentral heat pump
Nominal size4 ton
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceSeptember 4, 2025
Last certifiedJune 29, 2026
Cooling
SEER2Seasonal efficiency, higher is better18.5 (range 16.5-18.5)
EER2Efficiency at 95°F outdoors11.0-11.7
Cooling capacity46,000-48,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8-9.0
Capacity at 47°F45,000-50,500 BTU/h
Capacity at 17°F27,600-33,200 BTU/h
Capacity at 5°F21,800-32,600 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.80-2.26
ENERGY STAR cold climateNo
Heating output as it gets colder63% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with NCDC60DT5*-**+TDR at the standard test temperatures, in BTU/h:

Certified matchups66 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 66 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
NCDC60DT5*-**+TDRNF97D110M5C*18.511.08.530,400217733148
NCUC50CT5*-**+TDRNF97X080V4C*18.511.28.223,800217733044
NCUC50CT5*-**+TDRNF80X100V5C*18.511.28.223,600217733043
NAM48V2TA5*--18.211.28.423,200217733030
NAM60V2TA5*--18.011.29.032,600217733031
NCUC50CT5*-**+TDRNF80U110S5C*18.011.28.223,600217733038
NCUC50CT5*-**+TDRNF96U090S4C*18.011.28.223,400217733040
NCUC50CT5*-**+TDRNF97X080V5C*18.011.08.224,000217733045
NCUC50CT5*-**+TDRNF98U090M4C*18.011.28.223,800217733046
NCUC50CT5*-**+TDRNF98U090M5C*18.011.28.223,800217733047
NCUC50CT5*-**+TDRNF98U110M5C*18.011.28.223,800217733048
NCUC50CT5*-**+TDRNF80U090S4B*18.011.58.223,400217733129
NCUC50CT5*-**+TDRNF80L110S5C*18.011.28.223,600217733039
NCDC60CT5*-**+TDRNF80D110S5C*18.011.78.028,800217733146
NCUC50CT5*-**+TDRNF80U110V5C*18.011.28.023,600217733323
NCU[C,U]48CT5*-**+TDRNF80L110S5C*18.011.57.822,200217733057
NCU[C,U]48CT5*-**+TDRNF96U090S4C*18.011.57.822,000217733058
NCU[C,U]48BT5*-**+TDRNF80U090T4B*18.011.57.822,200217733077
NAM48E1TA5*--18.011.77.823,400217733121
NCU[C,U]48CT5*-**+TDRNF80U090S4B*18.011.77.822,000217733130
NCU[C,U]48BT5*-**+TDRNF80U090S4B*18.011.77.822,000217733081
NCU[C,U]48BT5*-**+TDRNF80L090S4B*18.011.77.822,000217733084
NCUC50CT5*-**+TDRNF97U090V3C*18.011.27.823,200217733324
NCHC42BT5*-**+TDRNF80U090V4B*18.011.27.826,600217733334
NCU[C,U]48CT5*-**+TDRNF80U110S5C*18.011.57.822,200217733056
NCUC50CT5*-**+TDRNF97U090V5C*18.011.27.823,800217733325
NCU[C,U]48CT5*-**+TDRNF97U090T4C*18.011.57.822,000218159800
NCDC60DT5*-**+TDRNF97D110T5C*17.511.58.529,800218159799
NCHC51CT5*-**+TDRNF80U110S5C*17.511.28.229,000217733136
NCHC51CT5*-**+TDRNF80L110S5C*17.511.28.229,000217733137
NCUC50CT5*-**+TDRNF80X100S5C*17.511.08.223,800217733034
NCUC50CT5*-**+TDRNF80U110T5C*17.511.58.223,400217733036
NCHC51CT5*-**+TDRNF97U110V5C*17.511.28.129,000217733140
NCHC51CT5*-**+TDR-17.511.08.129,000217733281
NCDC48CT5*-**+TDRNF97D090V5C*17.511.28.124,800217733330
NCDC48CT5*-**+TDRNF97D110V5C*17.511.28.124,800217733331
NCHC51CT5*-**+TDRNF80U110V5C*17.511.28.129,000217733338
NCUC50CT5*-**+TDRNF97U110V5C*17.511.28.023,600217733042
NCHC51CT5*-**+TDRNF97U090V5C*17.511.08.029,200217733339
NCU[C,U]48CT5*-**+TDRNF80X100S5C*17.511.27.822,400217733052
NCHC48CT5*-**+TDRNF80U090S5C*17.511.27.823,800217733070
NCHC48CT5*-**+TDRNF80U110S5C*17.511.57.823,600217733071
NCHC48CT5*-**+TDRNF80L110S5C*17.511.57.823,600217733072
NCHC51CT5*-**+TDRNF80U110T5C*17.011.28.228,600217733134
NCHC51CT5*-**+TDRNF80U090S5C*17.011.28.228,600217733135
NCHC51CT5*-**+TDRNF96U090S4C*17.011.08.228,800217733138
NCHC51CT5*-**+TDRNF80X100V5C*17.011.28.229,000217733141
NCHC51CT5*-**+TDRNF98U090M4C*17.011.08.229,000217733143
NCHC51CT5*-**+TDRNF98U090M5C*17.011.08.229,000217733144
NCHC51CT5*-**+TDRNF98U110M5C*17.011.28.229,000217733145
NCUC50CT5*-**+TDRNF80U090S5C*17.011.58.223,200217733037
NCUC50CT5*-**+TDRNF96U110S5C*17.011.58.223,400217733041
NCHC51CT5*-**+TDRNF97U110T5C*17.011.08.229,000218159802
NCUC50CT5*-**+TDRNF97U110T5C*17.011.58.223,400218159801
NCUC50CT5*-**+TDRNF95X100S5C*17.011.08.123,800217733035
NCDC60CT5*-**+TDRNF96D090S4C*17.011.28.029,000217733147
NCU[C,U]48CT5*-**+TDRNF80U110T5C*17.011.77.821,800217733054
NCU[C,U]48CT5*-**+TDRNF80U090S5C*17.011.77.822,000217733055
NCU[C,U]48CT5*-**+TDRNF96U110S5C*17.011.57.822,000217733059
NCU[C,U]48CT5*-**+TDRNF95X080S4C*17.011.57.822,000217733053
Yearly running cost in 10 large cities$1,207-$3,285

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the GE NS19H60MA5-**A?
The GE NS19H60MA5-**A is rated at up to 18.5 SEER2 and 11.0 EER2 for cooling and up to 9.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 66 certified matchups SEER2 ranges from 16.5-18.5.
Is the GE NS19H60MA5-**A good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 4-ton model.
How much does the GE NS19H60MA5-**A cost to run per year?
At its rated efficiency it costs about $1,207-$3,285 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,496 in Phoenix and $2,750 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the GE NS19H60MA5-**A?
ENERGY STAR lists 66 certified combinations for this outdoor unit. The highest-rated ones use NCDC60DT5*-**+TDR, NCUC50CT5*-**+TDR, NAM48V2TA5*-.
What refrigerant does the GE NS19H60MA5-**A use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,489/yrYou save $952/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump GE NS19H60MA5-**A
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,489
Current system, per year
$2,441
You save per year
$952
Payback
18.9 years
Net after 10 years
-$8,476

Cooling $904Heating $585Electricity used: 9,304 kWhSaved vs. a minimum-efficiency heat pump: $382

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 4 ton models

See all 319 4 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of June 29, 2026. How we use the data.