HVAC Rated

2-ton central heat pump · 15 SEER2 HP

Airquest R5H5S24*K*AAA

Average cooling efficiency and below average heating efficiency for a 2-ton central heat pump, but not rated for cold climates.

Ranks #253 of 331 2 ton central heat pumps for cooling efficiency, and costs about $721 a year to run in a mixed climate like Atlanta.

SEER2
16.5 Cooling efficiency over a season
Average · beats 40%
HSPF2
8.5 Heating efficiency over a season
Below average · beats 38%
EER2
13.0 Cooling efficiency on a 95°F day
Very good · beats 89%
Heat at 5°F
11,900 BTU/h49% of its 47°F output
Very good · beats 83%

A good fit if…

  • You want a choice of indoor units - 1,988 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.
  • Comfort and noise matter - a single-stage compressor runs only full-on or off.

Calculate my running cost

Details

Specifications2 ton, R-454B
General
BrandAirquest
Also sold asKeeprite, Tempstar, Kenmore, Heil, Arcoaire, Comfortmaker, Day & Night, ACIQ, Smart Comfort, MARATHERM
Outdoor unit modelR5H5S24*K*AAA
Series15 SEER2 HP
TypeCentral heat pump
Nominal size2 ton
CompressorVariable-speed units run longer at low powerSingle stage
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceJanuary 1, 2024
Last certifiedJune 29, 2026
Cooling
SEER2Seasonal efficiency, higher is better16.5 (range 15.2-16.5)
EER2Efficiency at 95°F outdoors11.7-13.0
Cooling capacity22,200-24,400 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8-8.5
Capacity at 47°F21,600-24,000 BTU/h
Capacity at 17°F14,200-15,200 BTU/h
Capacity at 5°F10,800-11,900 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.96-2.26
ENERGY STAR cold climateNo
Heating output as it gets colder49% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with FMA5X30**AL at the standard test temperatures, in BTU/h:

Certified matchups1,988 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 1,988 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
FMA5X30**AL-16.513.08.511,600214424078
FMA5X30**AL-16.513.08.511,600214424088
FMA5X30**AL-16.513.08.511,600214424080
FMA5X30**AL-16.513.08.511,600214424082
FMA5X30**AL-16.513.08.511,600214424084
FMA5X30**AL-16.513.08.511,600214424086
FMA5X30**AL-16.513.08.511,600214424090
FMA5X30**AL-16.513.08.511,600214424092
FMA5X30**AL-16.513.08.511,600214424094
FMA5X30**AL-16.513.08.511,600214424096
FMA5X30**AL-16.513.08.511,600216630616
EA*5X37M21A*97VTN1002122A*16.013.08.011,400215800299
EA*5X37M21A*97VTN1002120A*16.012.58.011,500215800258
EA*5X37M21A*97VTN1002120A*16.012.58.011,500215800260
EA*5X37M21A*97VTN1002120A*16.012.58.011,500215800262
EA*5X37M21A*97VTN1002120A*16.012.58.011,500215800264
EA*5X37M21A*97VTN1002120A*16.012.58.011,500215800266
EA*5X37M21A*97VTN1002120A*16.012.58.011,500215800268
EA*5X37M21A*97VTN1002120A*16.012.58.011,500215800270
EA*5X37M21A*97VTN1002120A*16.012.58.011,500215800272
EA*5X37M21A*97VTN1002120A*16.012.58.011,500215800274
EA*5X37M21A*97VTN1002122A*16.013.08.011,400215800283
EA*5X37M21A*97VTN1002122A*16.013.08.011,400215800285
EA*5X37M21A*97VTN1002122A*16.013.08.011,400215800287
EA*5X37M21A*97VTN1002122A*16.013.08.011,400215800289
EA*5X37M21A*97VTN1002122A*16.013.08.011,400215800291
EA*5X37M21A*97VTN1002122A*16.013.08.011,400215800293
EA*5X37M21A*97VTN1002122A*16.013.08.011,400215800295
EA*5X37M21A*97VTN1002122A*16.013.08.011,400215800297
EA*5X37M21A*97VTN1002120A*16.012.58.011,500215818019
EA*5X37M21A*97VTN1002122A*16.013.08.011,400215818021
EVD5X31M17A*80VSL0901716B*16.012.07.811,300214205063
EVD5X31M17A*80VSL0901716B*16.012.07.811,300214205065
EVD5X31M17A*80VSL0901716B*16.012.07.811,300214205067
EVD5X31M17A*80VSL0901716B*16.012.07.811,300214205069
EVD5X31M17A*80VSL0901716B*16.012.07.811,300214205071
EVD5X31M17A*80VSL0901716B*16.012.07.811,300214205073
EVD5X31M17A*80VSL0901716B*16.012.07.811,300214205075
EVD5X31M17A*80VSL0901716B*16.012.07.811,300214205077
EVD5X31M17A*80VSL0901716B*16.012.07.811,300214205079
EVM5X32M17A*80MSU0601716A*16.012.57.811,300214212742
EVM5X32M17A*80MSU0601716A*16.012.57.811,300214212744
EVM5X32M17A*80MSU0601716A*16.012.57.811,300214212746
EVM5X32M17A*80MSU0601716A*16.012.57.811,300214212748
EVM5X32M17A*80MSU0601716A*16.012.57.811,300214212750
EVM5X32M17A*80MSU0601716A*16.012.57.811,300214212752
EVM5X32M17A*80MSU0601716A*16.012.57.811,300214212754
EVM5X32M17A*80MSU0601716A*16.012.57.811,300214212756
EVM5X32M17A*80MSU0601716A*16.012.57.811,300214212758
EVD5X38M17A*80VTL0701716B*16.012.07.811,400214214362
EVD5X38M17A*80VTL0701716B*16.012.07.811,400214214364
EVD5X38M17A*80VTL0701716B*16.012.07.811,400214214366
EVD5X38M17A*80VTL0701716B*16.012.07.811,400214214368
EVD5X38M17A*80VTL0701716B*16.012.07.811,400214214370
EVD5X38M17A*80VTL0701716B*16.012.07.811,400214214372
EVD5X38M17A*80VTL0701716B*16.012.07.811,400214214374
EVD5X38M17A*80VTL0701716B*16.012.07.811,400214214376
EVD5X38M17A*80VTL0701716B*16.012.07.811,400214214378
EVD5X37M21A*80MS(N,L)0902116A*16.012.07.811,200214213399
EVD5X37M21A*80MS(N,L)0902116A*16.012.07.811,200214213401
Yearly running cost in 10 large cities$671-$1,702

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Airquest R5H5S24*K*AAA?
The Airquest R5H5S24*K*AAA is rated at up to 16.5 SEER2 and 13.0 EER2 for cooling and up to 8.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 1988 certified matchups SEER2 ranges from 15.2-16.5.
Is the Airquest R5H5S24*K*AAA good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 2-ton model.
How much does the Airquest R5H5S24*K*AAA cost to run per year?
At its rated efficiency it costs about $671-$1,702 a year in electricity in large U.S. cities, depending on climate and local rates - for example $814 in Phoenix and $1,412 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Airquest R5H5S24*K*AAA?
ENERGY STAR lists 1988 certified combinations for this outdoor unit. The highest-rated ones use FMA5X30**AL, EA*5X37M21A, EVD5X31M17A.
What refrigerant does the Airquest R5H5S24*K*AAA use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $801/yrYou save $399/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Airquest R5H5S24*K*AAA
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$801
Current system, per year
$1,201
You save per year
$399
Payback
22.5 years
Net after 10 years
-$5,007

Cooling $503Heating $298Electricity used: 5,008 kWhSaved vs. a minimum-efficiency heat pump: $117

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 2 ton models

See all 331 2 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of June 29, 2026. How we use the data.