HVAC Rated

2-ton central heat pump · LEGACY 15 SEER2 HP

Bryant 235SAN024**AA

Average cooling efficiency and below average heating efficiency for a 2-ton central heat pump, but not rated for cold climates.

Ranks #254 of 331 2 ton central heat pumps for cooling efficiency, and costs about $721 a year to run in a mixed climate like Atlanta.

SEER2
16.5 Cooling efficiency over a season
Average · beats 40%
HSPF2
8.5 Heating efficiency over a season
Below average · beats 38%
EER2
13.0 Cooling efficiency on a 95°F day
Very good · beats 89%
Heat at 5°F
11,900 BTU/h49% of its 47°F output
Very good · beats 83%

A good fit if…

  • You want a choice of indoor units - 199 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.
  • Comfort and noise matter - a single-stage compressor runs only full-on or off.

Calculate my running cost

Details

Specifications2 ton, R-454B
General
BrandBryant
Outdoor unit model235SAN024**AA
SeriesLEGACY 15 SEER2 HP
TypeCentral heat pump
Nominal size2 ton
CompressorVariable-speed units run longer at low powerSingle stage
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceJanuary 1, 2024
Last certifiedJune 16, 2026
Cooling
SEER2Seasonal efficiency, higher is better16.5 (range 15.2-16.5)
EER2Efficiency at 95°F outdoors11.7-13.0
Cooling capacity22,200-24,400 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8-8.5
Capacity at 47°F21,600-24,000 BTU/h
Capacity at 17°F14,200-15,200 BTU/h
Capacity at 5°F10,800-11,900 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.96-2.26
ENERGY STAR cold climateNo
Heating output as it gets colder49% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with FMA5X30**AL at the standard test temperatures, in BTU/h:

Certified matchups199 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 199 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
FMA5X30**AL-16.513.08.511,600214424070
CAA**3721AM927TA60100V21***16.012.58.011,500215800250
CAA**3721AM927TA66100V21***16.013.08.011,400215800278
CVAVA3117XMA82*SB48090V17***16.012.07.811,300214205058
CVAVA3117XMA82*TB48090V17***16.012.07.811,300214205204
CVAMA3217XMA83*SB48060M17***16.012.57.811,300214212734
CVAVA3817XMA82*TB48090V17***16.012.57.811,400214214382
CVAVA3817XMA82*TB48070V17***16.012.07.811,400214214354
CVAVA3721XMA8(0,1)*SB48090M21***16.012.07.811,200214213391
CAA**3721AM83*CA60080C21***16.012.57.811,300214210908
CVAMA3217XMA82*SB48090V17***16.012.07.811,400214212645
CAA**3721AM935SB60100M21***16.012.07.811,500214211966
CVAVA3817XMA912SE42060M17***16.012.07.811,400214214481
CAA**3721AM986TC66100C21***16.012.57.811,200214212021
CVAMA3217XMA82*TB48090V17***16.012.07.811,400214212890
CAA**3721AM986TD60080C21***16.012.57.811,400214212048
CAA**3721AM986TD66100C21***16.012.57.811,500214212075
CVAMA3217XMA912SE48080M17***16.012.07.811,200214212994
CAA**2517AM83*SB36040M17***16.012.57.811,300214210526
CAA**2517AM83*SB48060M17***16.012.07.811,200214210558
CVAVA3817XMA8(0,1)*SB36070M17***16.012.57.811,400214213971
CAA**3721AM88*TB60090C21***16.012.57.811,500214211428
CVAMA3117XMA83*SB48060M17***16.012.07.811,200214212346
CAA**3721AM82*TB66110V21***16.012.07.811,500214211485
CVAVA3817XMA8(0,1)*SB42090M17***16.012.57.811,200214214033
CVAVA3817XMA8(0,1)*SB48070M17***16.012.07.811,400214214001
CAA**2517AM88*TB36070C14***16.012.57.811,400214210617
CAA**3721AM935CB66100C21***16.012.57.811,600214211540
CAA**3721AM987MB66100C21***16.012.57.811,200214211567
CAA**3721AM987MC60080C21***16.012.57.811,500214211594
CVAVA3817XMA83*SB48060M17***16.012.57.811,200214214229
CVAVA3117XMA83*SB48060M17***16.012.57.811,200214213270
CVAMA3217XMA8(0,1)*SB42090M17***16.012.07.811,200214212538
CVAVA3817XMA82*SB48070V17***16.012.07.811,300214214115
CAA**3721AM987MC66100C21***16.012.57.811,500214211621
CVAVA3817XMA82*SB48090V17***16.012.57.811,400214214140
CAA**3721AM83*CA36040C17***16.012.57.811,200214210881
FM(C,U)5Z30**AL-16.012.57.811,100215828930
FM(C,U)5Z36**AL-16.012.57.811,100215828962
FM(C,U)5Z24**AL-15.512.08.011,300215828898
FEVA0036**+NAVA53601CK-15.512.08.011,300217051514
FM(C,U)5S36**AL-15.512.58.011,200218452307
FM(C,U)5S30**AL-15.512.58.011,200218452275
FJ5AN*B36L-15.512.07.811,400214179765
PF5MN*B36L-15.512.07.811,400214179766
FT5ANXB24L-15.512.07.811,200214179846
FG5ANXB24L-15.512.07.811,200214179847
PF5TNXB24L-15.512.07.811,200214179848
CAA**2517AM916SA48060M17***15.512.07.811,400214198020
CAA**2517AM88*TB48090C17***15.512.07.811,400214197595
CAA**2517AM986TD42080C17***15.512.07.811,300214198369
CAA**2517AM986TD42060C17***15.512.07.811,400214198342
CAA**2517AM88*TB36045C17***15.512.07.811,500214197541
CAA**2517AM88*TB48070C17***15.512.07.811,400214197568
CAA**2517AM987MC42060C17***15.512.07.811,500214197810
CAA**2517AM935CB48060C17***15.512.07.811,300214197729
CAA**2517AM987MC42080C17***15.512.07.811,500214197837
CAA**3721AMOVLAAB04811215.512.07.811,500214203244
CAA**3717AM8(0,1)*SB48070M17***15.512.07.811,300214199788
CVAMA3217XMA926SB48080V17***15.512.07.811,300214204700
Same unit, other model numbers1

These model numbers have exactly the same certified ratings and matchups as the Bryant 235SAN024**AA: the same equipment under another brand, or a variant code for voltage, colour or market. Everything on this page applies to them.

Yearly running cost in 10 large cities$671-$1,702

At each state's average electricity price and the city's typical heating and cooling hours.

Questions6
What is the SEER2 rating of the Bryant 235SAN024**AA?
The Bryant 235SAN024**AA is rated at up to 16.5 SEER2 and 13.0 EER2 for cooling and up to 8.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 199 certified matchups SEER2 ranges from 15.2-16.5.
Is the Bryant 235SAN024**AA good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 2-ton model.
How much does the Bryant 235SAN024**AA cost to run per year?
At its rated efficiency it costs about $671-$1,702 a year in electricity in large U.S. cities, depending on climate and local rates - for example $814 in Phoenix and $1,412 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Is the Bryant 235SAN024**AA the same as the Bryant 246SAN024**AA?
Yes, as far as the certified ratings go. ENERGY STAR lists both model numbers with identical efficiency, capacity and matchups, which means the same outdoor unit sold under a different brand or with a minor variant code (voltage, colour or region). The full list is on this page.
Which indoor units work with the Bryant 235SAN024**AA?
ENERGY STAR lists 199 certified combinations for this outdoor unit. The highest-rated ones use FMA5X30**AL, CAA**3721AM, CVAVA3117XMA.
What refrigerant does the Bryant 235SAN024**AA use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $801/yrYou save $399/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Bryant 235SAN024**AA
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$801
Current system, per year
$1,201
You save per year
$399
Payback
22.5 years
Net after 10 years
-$5,007

Cooling $503Heating $298Electricity used: 5,008 kWhSaved vs. a minimum-efficiency heat pump: $117

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 2 ton models

See all 331 2 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of June 16, 2026. How we use the data.