HVAC Rated

2-ton central heat pump · COMFORT 15 SEER2 HP

Carrier 27SCA524A**30

Average cooling efficiency and below average heating efficiency for a 2-ton central heat pump, but not rated for cold climates.

Ranks #256 of 331 2 ton central heat pumps for cooling efficiency, and costs about $723 a year to run in a mixed climate like Atlanta.

SEER2
16.5 Cooling efficiency over a season
Average · beats 40%
HSPF2
8.5 Heating efficiency over a season
Below average · beats 38%
EER2
13.0 Cooling efficiency on a 95°F day
Very good · beats 89%
Heat at 5°F
11,900 BTU/h49% of its 47°F output
Very good · beats 83%

A good fit if…

  • You want a choice of indoor units - 206 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.
  • Comfort and noise matter - a single-stage compressor runs only full-on or off.

Calculate my running cost

Details

Specifications2 ton, R-454B
General
BrandCarrier
Outdoor unit model27SCA524A**30
SeriesCOMFORT 15 SEER2 HP
TypeCentral heat pump
Nominal size2 ton
CompressorVariable-speed units run longer at low powerSingle stage
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceJanuary 1, 2024
Last certifiedJune 16, 2026
Cooling
SEER2Seasonal efficiency, higher is better16.5 (range 15.2-16.5)
EER2Efficiency at 95°F outdoors11.7-13.0
Cooling capacity22,200-24,400 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8-8.5
Capacity at 47°F21,600-24,000 BTU/h
Capacity at 17°F14,200-15,200 BTU/h
Capacity at 5°F10,800-11,900 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.96-2.26
ENERGY STAR cold climateNo
Heating output as it gets colder49% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with FMA5X30**AL at the standard test temperatures, in BTU/h:

Certified matchups206 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 206 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
FMA5X30**AL-16.513.08.511,600214424067
CAA**3721AM59TP7A100V21**2016.012.58.011,500215800247
CAA**3721AM59TP7A100V21**2216.013.08.011,400215800275
CVAVA3117XMA58SP*B090V17**1616.012.07.811,300214205055
CVAVA3117XMA58TP*B090V17**1616.012.07.811,300214205201
CVAMA3217XMA58SU*B060M17**1616.012.57.811,300214212731
CVAVA3817XMA58TP*B090V17**1616.012.57.811,400214214379
CVAVA3817XMA58TP*B070V17**1616.012.07.811,400214214351
CVAVA3721XMA58S(B,C)*B090M21**1616.012.07.811,200214213388
CAA**3721AM58CU*A080C21**2016.012.57.811,300214210905
CVAMA3217XMA58SP*B090V17**1616.012.07.811,400214212642
CAA**3721AM59SU5B100M21**2016.012.07.811,500214211963
CVAVA3817XMA59SC2E060M17**1416.012.07.811,400214214478
CAA**3721AM59TN6B100C21**2216.012.57.811,200214212018
CVAMA3217XMA58TP*B090V17**1616.012.07.811,400214212887
CAA**3721AM59TN6C080C21**2016.012.57.811,400214212045
CAA**3721AM59TN6C100C21**2216.012.57.811,500214212072
CVAMA3217XMA59SC2E080M17**1616.012.07.811,200214212991
CAA**2517AM58SU*B040M17**1216.012.57.811,300214210523
CAA**2517AM58SU*B060M17**1616.012.07.811,200214210555
CVAVA3817XMA58S(B,C)*B070M17**1216.012.57.811,400214213968
CAA**3721AM58TN*B090C21**2016.012.57.811,500214211425
CVAMA3117XMA58SU*B060M17**1616.012.07.811,200214212343
CAA**3721AM58TP*B110V21**2216.012.07.811,500214211482
CVAVA3817XMA58S(B,C)*B090M17**1416.012.57.811,200214214030
CVAVA3817XMA58S(B,C)*B070M17**1616.012.07.811,400214213998
CAA**2517AM58TN*B070C14**1216.012.57.811,400214210614
CAA**3721AM59CU5B100C21**2216.012.57.811,600214211537
CAA**3721AM59MN7B100C21**2216.012.57.811,200214211564
CAA**3721AM59MN7C080C21**2016.012.57.811,500214211591
CVAVA3817XMA58SU*B060M17**1616.012.57.811,200214214226
CVAVA3117XMA58SU*B060M17**1616.012.57.811,200214213267
CVAMA3217XMA58S(B,C)*B090M17**1416.012.07.811,200214212535
CVAVA3817XMA58SP*B070V17**1616.012.07.811,300214214112
CAA**3721AM59MN7C100C21**2216.012.57.811,500214211618
CVAVA3817XMA58SP*B090V17**1616.012.57.811,400214214137
CAA**3721AM58CU*A040C17**1216.012.57.811,200214210878
FM(C,U)5Z30**AL-16.012.57.811,100215828927
FM(C,U)5Z36**AL-16.012.57.811,100215828959
FM(C,U)5Z24**AL-15.512.08.011,300215828895
FEVA0036**+NAVA53601CK-15.512.08.011,300217051511
FM(C,U)5S36**AL-15.512.58.011,200218452304
FM(C,U)5S30**AL-15.512.58.011,200218452272
FJ5AN*B36L-15.512.07.811,400214179762
FT5ANXB24L-15.512.07.811,200214179841
CAA**2517AM59SC6A060M17**1615.512.07.811,400214198017
CAA**2517AM58TN*B090C17**1615.512.07.811,400214197592
CAA**2517AM59TN6C080C17**1415.512.07.811,300214198366
CAA**2517AM59TN6C060C17**1415.512.07.811,400214198339
CAA**2517AM58TN*B045C17**1215.512.07.811,500214197538
CAA**2517AM58TN*B070C17**1615.512.07.811,400214197565
CAA**2517AM59MN7C060C17**1415.512.07.811,500214197807
CAA**2517AM59CU5B060C17**1615.512.07.811,300214197726
CAA**2517AM59MN7C080C17**1415.512.07.811,500214197834
CAA**3721AMOVLAAB04811215.512.07.811,500214203241
CAA**3717AM58S(B,C)*B070M17**1615.512.07.811,300214199785
CVAMA3217XMA59SP6B080V17**1615.512.07.811,300214204697
CVAVA3117XMA59SU5B060M17**1615.512.07.811,300214205594
CAA**3721AM58TN*B110C21**2015.512.57.811,600214201948
CAA**3721AM59SU5B080M21**2015.512.57.811,600214202831
Same unit, other model numbers1

These model numbers have exactly the same certified ratings and matchups as the Carrier 27SCA524A**30: the same equipment under another brand, or a variant code for voltage, colour or market. Everything on this page applies to them.

Yearly running cost in 10 large cities$676-$1,705

At each state's average electricity price and the city's typical heating and cooling hours.

Questions6
What is the SEER2 rating of the Carrier 27SCA524A**30?
The Carrier 27SCA524A**30 is rated at up to 16.5 SEER2 and 13.0 EER2 for cooling and up to 8.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 206 certified matchups SEER2 ranges from 15.2-16.5.
Is the Carrier 27SCA524A**30 good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 2-ton model.
How much does the Carrier 27SCA524A**30 cost to run per year?
At its rated efficiency it costs about $676-$1,705 a year in electricity in large U.S. cities, depending on climate and local rates - for example $819 in Phoenix and $1,413 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Is the Carrier 27SCA524A**30 the same as the Carrier 27SPA624A**30?
Yes, as far as the certified ratings go. ENERGY STAR lists both model numbers with identical efficiency, capacity and matchups, which means the same outdoor unit sold under a different brand or with a minor variant code (voltage, colour or region). The full list is on this page.
Which indoor units work with the Carrier 27SCA524A**30?
ENERGY STAR lists 206 certified combinations for this outdoor unit. The highest-rated ones use FMA5X30**AL, CAA**3721AM, CVAVA3117XMA.
What refrigerant does the Carrier 27SCA524A**30 use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $806/yrYou save $402/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Carrier 27SCA524A**30
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$806
Current system, per year
$1,208
You save per year
$402
Payback
22.4 years
Net after 10 years
-$4,980

Cooling $508Heating $298Electricity used: 5,035 kWhSaved vs. a minimum-efficiency heat pump: $118

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 2 ton models

See all 331 2 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of June 16, 2026. How we use the data.