HVAC Rated

4-ton central heat pump · GOLD 17

American Standard 5A6H7060A1

Average cooling and heating efficiency for a 4-ton central heat pump, and certified for cold climates.

Ranks #156 of 319 4 ton central heat pumps for cooling efficiency, and costs about $1,529 a year to run in a mixed climate like Atlanta.

SEER2
17.1 Cooling efficiency over a season
Average · beats 53%
HSPF2
9.0 Heating efficiency over a season
Average · beats 54%
EER2
11.7 Cooling efficiency on a 95°F day
Average · beats 43%
Heat at 5°F
39,500 BTU/h75% of its 47°F output
Very good · beats 80%

A good fit if…

  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 39,500 BTU/h at 5°F.
  • You want a choice of indoor units - 139 certified pairings.

Think twice if…

  • Nothing stands out - its ratings have no weak spot for its class.

Calculate my running cost

Details

Specifications4 ton, R-454B
General
BrandAmerican Standard
Outdoor unit model5A6H7060A1
SeriesGOLD 17
TypeCentral heat pump
Nominal size4 ton
CompressorVariable-speed units run longer at low powerTwo-stage
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceJanuary 15, 2025
Last certifiedJuly 17, 2026
Cooling
SEER2Seasonal efficiency, higher is better17.1 (range 15.2-17.1)
EER2Efficiency at 95°F outdoors10.0-11.7
Cooling capacity50,500-53,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better8.5-9.0
Capacity at 47°F50,500-52,000 BTU/h
Capacity at 17°F33,400-47,500 BTU/h
Capacity at 5°F38,000-39,500 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.10-2.22
ENERGY STAR cold climateYes
Heating output as it gets colder75% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with 5TEM6D07AV51+TDR at the standard test temperatures, in BTU/h:

Certified matchups139 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 139 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
5TEM6D07AV51+TDR · cold climate-17.111.79.038,000216764084
5TEM6D06AV41+TDR · cold climate-17.011.79.038,000216764082
5TEMCD07AV51+TDR · cold climate-17.011.79.038,000216764088
5TXCD010AS3 · cold climateS8X1D120M5PSC17.011.29.038,500216764096
5PX*D010AS3 · cold climateS8X1D120M5PSC17.011.29.038,500216764060
5TXCD010AS3 · cold climateS8X2D120M5PTC17.011.29.038,500216764902
5TXCD010AS3 · cold climateS8X2D120M5PSC17.011.29.038,500216764904
5PX*D010AS3 · cold climateS8X2D120M5PTC17.011.29.038,500216764868
5PX*D010AS3 · cold climateS8X1D120M5PTC17.011.29.038,500216764874
5PX*D010AS3 · cold climateS8X2D120M5PSC17.011.29.038,500216764876
5TEMCD06AV41+TDR · cold climate-16.511.79.038,000216764086
5TXCD010AS3 · cold climateS9V2D120U5PSC16.511.29.038,500216764104
5TXCD010AS3 · cold climateS9V2D120U5VSB16.511.29.038,500216764106
5PX*D008AS3 · cold climateS9V2D120U5VSB16.511.29.039,000216764034
5PX*D008AS3 · cold climateS9V2D120U5PSC16.511.29.039,000216764036
5PX*D010AS3 · cold climateS8X1C100M5PSC16.511.29.038,500216764062
5PX*D010AS3 · cold climateS8X1C080M5PSC16.511.29.038,500216764064
5PX*D010AS3 · cold climateL8V1C100U5VSB16.511.29.038,500216764070
5TXCD010AS3 · cold climateS9V2C080U5PSC16.511.29.038,500216764094
5TXCD010AS3 · cold climateS8X1C100M5PSC16.511.29.038,500216764098
5TXCD010AS3 · cold climateL8V1C100U5VSB16.511.29.038,500216764102
5PX*D008AS3 · cold climateS8X1C100M5PSC16.511.09.039,000216764044
5PX*D008AS3 · cold climateS8X1C080M5PSC16.511.09.039,000216764046
5PX*D008AS3 · cold climateS8X1D120M5PSC16.511.09.039,000216764052
5PX*D010AS3 · cold climateS9V2D120U5VSB16.511.29.038,500216764054
5PX*D010AS3 · cold climateS9V2D120U5PSC16.511.29.038,500216764056
5PX*D010AS3 · cold climateS9V2C080U5PSC16.511.29.038,500216764058
5TXCD010AS3 · cold climateS8X1C080M5PTC16.511.29.038,500216764896
5TXCD010AS3 · cold climateS8X1C100M5PTC16.511.29.038,500216764898
5TXCD010AS3 · cold climateS8X2C100M5PTC16.511.29.038,500216764900
5TXCD010AS3 · cold climateS8X2C080M5PTC16.511.29.038,500216764906
5TXCD010AS3 · cold climateS8X2C100M5PSC16.511.29.038,500216764908
5PX*D008AS3 · cold climateS8X2C080M5PSC16.511.09.039,000216764842
5PX*D008AS3 · cold climateS8X2C100M5PSC16.511.09.039,000216764844
5PX*D008AS3 · cold climateS8X1D120M5PTC16.511.09.039,000216764846
5PX*D008AS3 · cold climateS8X1C080M5PTC16.511.09.039,000216764850
5PX*D008AS3 · cold climateS8X2D120M5PTC16.511.09.039,000216764852
5PX*D008AS3 · cold climateS8X2C100M5PTC16.511.09.039,000216764854
5PX*D008AS3 · cold climateS8X2C080M5PTC16.511.09.039,000216764856
5PX*D008AS3 · cold climateS8X2D120M5PSC16.511.09.039,000216764858
5PX*D010AS3 · cold climateS8X1C100M5PTC16.511.29.038,500216764860
5PX*D010AS3 · cold climateS8X1C080M5PTC16.511.29.038,500216764862
5PX*D010AS3 · cold climateS8X2C100M5PSC16.511.29.038,500216764864
5PX*D010AS3 · cold climateS8X2C080M5PSC16.511.29.038,500216764866
5PX*D010AS3 · cold climateS8X2C100M5PTC16.511.29.038,500216764870
5PX*D010AS3 · cold climateS8X2C080M5PTC16.511.29.038,500216764872
5PX*DD10AS3 · cold climateS8X1D120M5PSC16.511.08.738,500216764076
5PX*DD10AS3 · cold climateS8X2D120M5PTC16.511.08.738,500216764894
5PX*DD10AS3 · cold climateS8X2D120M5PSC16.511.08.738,500216764886
5PX*DD10AS3 · cold climateS8X1D120M5PTC16.511.08.738,500216764880
5TXCD010AS3+P0V0D000M50SD · cold climate-16.011.79.038,000216766759
5PX*D010AS3+P0V0D000M50SD · cold climate-16.011.79.038,000216766691
5PX*D008AS3 · cold climateS9V2C080U5PSC16.011.09.039,000216764040
5PX*D010AS3 · cold climateL9X1C100U5VSA16.010.09.039,000216764068
5PX*DD10AS3 · cold climateS8X1C080M5PSC16.011.09.038,500216764072
5PX*DD10AS3 · cold climateS9V2D120D5PSC16.011.09.038,500216764078
5PX*DD10AS3 · cold climateS8X1C100M5PSC16.011.09.038,500216764080
5TXCD008AS3 · cold climate*UHMD120CCV516.010.09.039,500216764092
5TXCD010AS3 · cold climateL9X1C100U5VSA16.010.09.039,000216764100
5PX*D008AS3 · cold climateL8V1C100U5VSB16.011.09.039,000216764050
Yearly running cost in 10 large cities$1,413-$3,619

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the American Standard 5A6H7060A1?
The American Standard 5A6H7060A1 is rated at up to 17.1 SEER2 and 11.7 EER2 for cooling and up to 9.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 139 certified matchups SEER2 ranges from 15.2-17.1.
Is the American Standard 5A6H7060A1 good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 39,500 BTU/h at 5°F with a COP of 2.22, so it is still 2.2 times as efficient as electric resistance heat at that temperature.
How much does the American Standard 5A6H7060A1 cost to run per year?
At its rated efficiency it costs about $1,413-$3,619 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,720 in Phoenix and $3,006 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the American Standard 5A6H7060A1?
ENERGY STAR lists 139 certified combinations for this outdoor unit. The highest-rated ones use 5TEM6D07AV51+TDR, 5TEM6D06AV41+TDR, 5TEMCD07AV51+TDR.
What refrigerant does the American Standard 5A6H7060A1 use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,695/yrYou save $953/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump American Standard 5A6H7060A1
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,695
Current system, per year
$2,647
You save per year
$953
Payback
20.5 years
Net after 10 years
-$9,975

Cooling $1,060Heating $635Electricity used: 10,592 kWhSaved vs. a minimum-efficiency heat pump: $335

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 4 ton models

See all 319 4 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of July 17, 2026. How we use the data.