1.5-ton central heat pump · D5C Series
Arcoaire D5CURAH18AAK
Very good cooling efficiency and average heating efficiency for a 1.5-ton central heat pump, but not rated for cold climates.
Ranks #39 of 170 1.5 ton central heat pumps for cooling efficiency, and costs about $505 a year to run in a mixed climate like Atlanta.
- SEER2
- 18.8 Cooling efficiency over a seasonVery good · beats 81%
- HSPF2
- 9.4 Heating efficiency over a seasonAverage · beats 64%
- EER2
- 11.0 Cooling efficiency on a 95°F dayBelow average · beats 23%
- Heat at 5°F
- 11,400 BTU/h62% of its 47°F outputAverage · beats 58%
A good fit if…
- You want low cooling bills - its SEER2 beats 81% of central heat pumps.
- You want steady temperatures and quiet running - the compressor varies its speed.
- You want a choice of indoor units - 25 certified pairings.
Think twice if…
- You often see nights below 0°F - it is not cold-climate certified.
Details
Specifications
| General | |
|---|---|
| Brand | Arcoaire |
| Also sold as | Comfortmaker, Day & Night, Heil, Keeprite, Kenmore, Tempstar, Smart Comfort, Airquest, LPS Legacy, Grandaire, Viessmann, Midea |
| Outdoor unit model | D5CURAH18AAK |
| Series | D5C Series |
| Type | Central heat pump |
| Nominal size | 1.5 ton |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-454B |
| Connected (smart) capable | No |
| On the market since | November 15, 2018 |
| Last certified | July 14, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 18.8 (range 18.5-18.8) |
| EER2Efficiency at 95°F outdoors | 11.0-11.5 |
| Cooling capacity | 18,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 9.2-9.4 |
| Capacity at 47°F | 18,000 BTU/h |
| Capacity at 17°F | 12,600 BTU/h |
| Capacity at 5°F | 11,200-11,400 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 2.00-2.10 |
| ENERGY STAR cold climate | No |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with D5FUAAH18XAK at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|
| D5FUAAH18XAK | 18.8 | 11.0 | 9.2 | 11,200 | 215318895 |
| D5FUAAH18XAK | 18.8 | 11.0 | 9.2 | 11,200 | 215318923 |
| D5FUAAH18XAK | 18.8 | 11.0 | 9.2 | 11,200 | 215318951 |
| D5FUAAH18XAK | 18.8 | 11.0 | 9.2 | 11,200 | 215318979 |
| D5FUAAH18XAK | 18.8 | 11.0 | 9.2 | 11,200 | 215319007 |
| D5FUAAH18XAK | 18.8 | 11.0 | 9.2 | 11,200 | 215319035 |
| D5FUAAH18XAK | 18.8 | 11.0 | 9.2 | 11,200 | 215319063 |
| D5FUAAH18XAK | 18.8 | 11.0 | 9.2 | 11,200 | 215319091 |
| D5FUAAH18XAK | 18.8 | 11.0 | 9.2 | 11,200 | 215319119 |
| D5FUAAH18XAK | 18.8 | 11.0 | 9.2 | 11,200 | 215319147 |
| D5FUAAH18XAK | 18.8 | 11.0 | 9.2 | 11,200 | 215319175 |
| D5FUAAH18XAK | 18.8 | 11.0 | 9.2 | 11,200 | 215319203 |
| D5FUAAH18XAK | 18.8 | 11.0 | 9.2 | 11,200 | 217178775 |
| D5MUWAQ18XA3 | 18.5 | 11.5 | 9.4 | 11,400 | 218213822 |
| D5MUWAQ18XA3 | 18.5 | 11.5 | 9.4 | 11,400 | 218213820 |
| D5MUWAQ18XA3 | 18.5 | 11.5 | 9.4 | 11,400 | 218213818 |
| D5MUWAQ18XA3 | 18.5 | 11.5 | 9.4 | 11,400 | 218213816 |
| D5MUWAQ18XA3 | 18.5 | 11.5 | 9.4 | 11,400 | 218213814 |
| D5MUWAQ18XA3 | 18.5 | 11.5 | 9.4 | 11,400 | 218213812 |
| D5MUWAQ18XA3 | 18.5 | 11.5 | 9.4 | 11,400 | 218213810 |
| D5MUWAQ18XA3 | 18.5 | 11.5 | 9.4 | 11,400 | 218213808 |
| D5MUWAQ18XA3 | 18.5 | 11.5 | 9.4 | 11,400 | 218213806 |
| D5MUWAQ18XA3 | 18.5 | 11.5 | 9.4 | 11,400 | 218213804 |
| D5MUWAQ18XA3 | 18.5 | 11.5 | 9.4 | 11,400 | 218213802 |
| D5MUWAQ18XA3 | 18.5 | 11.5 | 9.4 | 11,400 | 218668525 |
Yearly running cost in 10 large cities
- Phoenix, AZ$555/yr
- Miami, FL$450/yr
- Houston, TX$498/yr
- Atlanta, GA$505/yr
- Los Angeles, CA$492/yr
- New York, NY$1,208/yr
- Chicago, IL$981/yr
- Denver, CO$816/yr
- Seattle, WA$502/yr
- Minneapolis, MN$1,010/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the Arcoaire D5CURAH18AAK?
- The Arcoaire D5CURAH18AAK is rated at up to 18.8 SEER2 and 11.0 EER2 for cooling and up to 9.4 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 25 certified matchups SEER2 ranges from 18.5-18.8.
- Is the Arcoaire D5CURAH18AAK good for cold climates?
- It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 1.5-ton model.
- How much does the Arcoaire D5CURAH18AAK cost to run per year?
- At its rated efficiency it costs about $450-$1,208 a year in electricity in large U.S. cities, depending on climate and local rates - for example $555 in Phoenix and $1,010 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the Arcoaire D5CURAH18AAK?
- ENERGY STAR lists 25 certified combinations for this outdoor unit. The highest-rated ones use D5FUAAH18XAK, D5MUWAQ18XA3.
- What refrigerant does the Arcoaire D5CURAH18AAK use?
- It uses R-454B.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 1.5 ton models
- MDV MOD30U-30HFN1-MR019.0 SEER2 · 8.2 HSPF2
- Carrier 37MURAQ18AA318.8 SEER2 · 9.4 HSPF2
- Goodman GZV6SA1810A · cold climate19.0 SEER2 · 8.8 HSPF2
- DuraSTAR DRU1U18S2A18.8 SEER2 · 9.4 HSPF2
- Daikin DH6VSA1810A · cold climate19.0 SEER2 · 8.8 HSPF2
- Innovair SOV18H2BA18.8 SEER2 · 9.4 HSPF2
- ZERO ZSOVA-18HDMB-USHH · cold climate19.0 SEER2 · 9.7 HSPF2
- Mainline ML18HP230LMNT-O18.8 SEER2 · 9.4 HSPF2
See all 170 1.5 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of July 14, 2026. How we use the data.