HVAC Rated

1.5-ton central heat pump · DH6VSA

Daikin DH6VSA1810A

Very good cooling efficiency and average heating efficiency for a 1.5-ton central heat pump, and certified for cold climates.

Ranks #36 of 170 1.5 ton central heat pumps for cooling efficiency, and costs about $492 a year to run in a mixed climate like Atlanta.

SEER2
19.0 Cooling efficiency over a season
Very good · beats 85%
HSPF2
8.8 Heating efficiency over a season
Average · beats 49%
EER2
12.0 Cooling efficiency on a 95°F day
Average · beats 64%
Heat at 5°F
13,000 BTU/h75% of its 47°F output
Average · beats 58%

A good fit if…

  • You want low cooling bills - its SEER2 beats 85% of central heat pumps.
  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 13,000 BTU/h at 5°F.
  • You want steady temperatures and quiet running - the compressor varies its speed.
  • You want a choice of indoor units - 70 certified pairings.

Think twice if…

  • Nothing stands out - its ratings have no weak spot for its class.

Calculate my running cost

Details

Specifications1.5 ton, R-32
General
BrandDaikin
Outdoor unit modelDH6VSA1810A
SeriesDH6VSA
TypeCentral heat pump
Nominal size1.5 ton
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-32
Connected (smart) capableYes
On the market sinceSeptember 3, 2024
Last certifiedJuly 28, 2026
Cooling
SEER2Seasonal efficiency, higher is better19.0 (range 16.0-19.0)
EER2Efficiency at 95°F outdoors11.0-12.0
Cooling capacity17,000-17,100 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better8.5-8.8
Capacity at 47°F16,800-17,400 BTU/h
Capacity at 17°F10,600-10,800 BTU/h
Capacity at 5°F12,600-13,000 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.00-2.10
ENERGY STAR cold climateYes
Heating output as it gets colder75% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with DFVE24BP1300A at the standard test temperatures, in BTU/h:

Certified matchups70 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 70 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
DFVE24BP1300A · cold climate-19.012.08.813,000215415502
DFVE24BP0300A · cold climate-19.012.08.813,000215429753
CA*EA3022*3A*+MBVK16CP1X00A · cold climate-19.012.08.813,000215439760
CA*EA2418*3A*+MBVK16CP1X00A · cold climate-19.012.08.813,000215439761
CHPEA2422*3A*+MBVK12BP1X00A · cold climate-19.012.08.813,000215439762
CA*EA3022*3A*+MBVK12BP1X00A · cold climate-19.012.08.813,000215439763
CA*EA2418*3A*+MBVK12BP1X00A · cold climate-19.012.08.813,000215439764
CA*EA3022*3A · cold climateD*96TC0804CNA*19.012.08.813,000215439634
CHPEA2422*3A · cold climateD*96TC0803BNA*19.012.08.813,000215439636
CA*EA2418*3A · cold climateD*96TC0804CNA*19.012.08.813,000215439635
CA*EA3022*3A · cold climateD*96TC0803BNA*19.012.08.813,000215439637
CA*EA2418*3A · cold climateD*96TC0803BNA*19.012.08.813,000215439638
CHPEA2422*3A · cold climateD*96TC0603BNA*19.012.08.813,000215439639
CA*EA3022*3A · cold climateD*96TC0603BNA*19.012.08.813,000215439640
CA*EA2418*3A · cold climateD*96TC0603BNA*19.012.08.813,000215439641
CHPEA2422*3A · cold climateD*96TC0403BNA*19.012.08.813,000215439642
CA*EA3022*3A · cold climateD*96TC0403BNA*19.012.08.813,000215439643
CA*EA2418*3A · cold climateD*96TC0403BNA*19.012.08.813,000215439644
CA*EA3022*3A · cold climateD*80TC0805C*A*19.012.08.813,000215439645
CA*EA2418*3A · cold climateD*80TC0805C*A*19.012.08.813,000215439646
CA*EA3022*3A · cold climateD*80TC0804C*A*19.012.08.813,000215439647
CA*EA2418*3A · cold climateD*80TC0804C*A*19.012.08.813,000215439648
CHPEA2422*3A · cold climateD*80TC0803B*A*19.012.08.813,000215439649
CA*EA3022*3A · cold climateD*80TC0803B*A*19.012.08.813,000215439650
CA*EA2418*3A · cold climateD*80TC0803B*A*19.012.08.813,000215439651
CHPEA2422*3A · cold climateD*80TC0604B*A*19.012.08.813,000215439652
CA*EA3022*3A · cold climateD*80TC0604B*A*19.012.08.813,000215439653
CA*EA2418*3A · cold climateD*80TC0604B*A*19.012.08.813,000215439654
CHPEA2422*3A · cold climateD*80TC0603B*A*19.012.08.813,000215439655
CA*EA3022*3A · cold climateD*80TC0603B*A*19.012.08.813,000215439656
CA*EA2418*3A · cold climateD*80TC0603B*A*19.012.08.813,000215439657
CA*EA3022*3A · cold climateD*96SC0805CUA*19.012.08.813,000215439658
CA*EA2418*3A · cold climateD*96SC0805CUA*19.012.08.813,000215439659
CHPEA2422*3A · cold climateD*96SC0603BUA*19.012.08.813,000215439660
CA*EA3022*3A · cold climateD*96SC0603BUA*19.012.08.813,000215439661
CA*EA2418*3A · cold climateD*96SC0603BUA*19.012.08.813,000215439662
CA*EA3022*3A · cold climateD*80SC0805CUA*19.012.08.813,000215439663
CHPEA2422*3A · cold climateD*80SC0604BUA*19.012.08.813,000215439665
CA*EA2418*3A · cold climateD*80SC0805CUA*19.012.08.813,000215439664
CA*EA3022*3A · cold climateD*80SC0604BUA*19.012.08.813,000215439666
CA*EA2418*3A · cold climateD*80SC0604BUA*19.012.08.813,000215439667
CA*EA3022*3A · cold climateD*97MC0804CNA*19.012.08.813,000215439668
CA*EA2418*3A · cold climateD*97MC0804CNA*19.012.08.813,000215439669
CHPEA2422*3A · cold climateD*97MC0803BNA*19.012.08.813,000215439670
CA*EA3022*3A · cold climateD*97MC0803BNA*19.012.08.813,000215439671
CA*EA2418*3A · cold climateD*97MC0803BNA*19.012.08.813,000215439672
CHPEA2422*3A · cold climateD*97MC0603BNA*19.012.08.813,000215439673
CA*EA3022*3A · cold climateD*97MC0603BNA*19.012.08.813,000215439674
CA*EA2418*3A · cold climateD*97MC0603BNA*19.012.08.813,000215439675
CA*EA3022*3A · cold climateD*96VC0804CNA*19.012.08.813,000215487463
CA*EA2418*3A · cold climateD*96VC0804CNA*19.012.08.813,000215487464
CHPEA2422*3A · cold climateD*96VC0803BNA*19.012.08.813,000215487465
CA*EA3022*3A · cold climateD*96VC0803BNA*19.012.08.813,000215487466
CA*EA2418*3A · cold climateD*96VC0803BNA*19.012.08.813,000215487467
CHPEA2422*3A · cold climateD*96VC0603BNA*19.012.08.813,000215487468
CA*EA3022*3A · cold climateD*96VC0603BNA*19.012.08.813,000215487469
CA*EA2418*3A · cold climateD*96VC0603BNA*19.012.08.813,000215487470
CHPEA2422*3A · cold climateD*96VC0403BNA*19.012.08.813,000215487471
CA*EA2418*3A · cold climateD*96VC0403BNA*19.012.08.813,000215487473
CA*EA3022*3A · cold climateD*96VC0403BNA*19.012.08.813,000215487472
Yearly running cost in 10 large cities$421-$1,190

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Daikin DH6VSA1810A?
The Daikin DH6VSA1810A is rated at up to 19.0 SEER2 and 12.0 EER2 for cooling and up to 8.8 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 70 certified matchups SEER2 ranges from 16.0-19.0.
Is the Daikin DH6VSA1810A good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 13,000 BTU/h at 5°F with a COP of 2.10, so it is still 2.1 times as efficient as electric resistance heat at that temperature.
How much does the Daikin DH6VSA1810A cost to run per year?
At its rated efficiency it costs about $421-$1,190 a year in electricity in large U.S. cities, depending on climate and local rates - for example $528 in Phoenix and $1,001 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Daikin DH6VSA1810A?
ENERGY STAR lists 70 certified combinations for this outdoor unit. The highest-rated ones use DFVE24BP1300A, DFVE24BP0300A, CA*EA3022*3A*+MBVK16CP1X00A.
What refrigerant does the Daikin DH6VSA1810A use?
It uses R-32.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $529/yrYou save $345/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Daikin DH6VSA1810A
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$529
Current system, per year
$873
You save per year
$345
Payback
18.9 years
Net after 10 years
-$3,055

Cooling $315Heating $214Electricity used: 3,305 kWhSaved vs. a minimum-efficiency heat pump: $141

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 1.5 ton models

See all 170 1.5 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of July 28, 2026. How we use the data.